{"id":7070,"date":"2026-09-27T17:10:53","date_gmt":"2026-09-27T09:10:53","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7070"},"modified":"2026-09-27T17:10:53","modified_gmt":"2026-09-27T09:10:53","slug":"leitfaden-fur-thermostatische-expansionsventile","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/de\/thermostatic-expansion-valve-guide\/","title":{"rendered":"Leitfaden f\u00fcr thermostatische Expansionsventile: Funktionsprinzip, \u00dcberhitzung, Auswahl und RFQ-Eingaben"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7070\" class=\"elementor elementor-7070\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00006b e-con-full e-flex e-con e-parent\" data-id=\"h00006b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000001 elementor-widget elementor-widget-image\" data-id=\"h000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero.webp\" class=\"attachment-full size-full wp-image-7059\" alt=\"Industrielle K\u00fchlanlage mit Kompressor und K\u00fchlregister in gewerblicher Umgebung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptillustration: Thermostatisches Expansionsventil installiert in einem gewerblichen K\u00e4ltekreislauf mit Verdampfer, F\u00fchler, Ausgleichsleitung und Fl\u00fcssigkeitsleitung.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000002 elementor-widget elementor-widget-text-editor\" data-id=\"h000002\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ein thermostatisches Expansionsventil (TEV) dosiert fl\u00fcssiges K\u00e4ltemittel in einen Direktverdampfer, indem es auf die \u00dcberhitzung am Verdampferausgang reagiert.<\/strong> Das Ventil gleicht F\u00fchlerdruck, Verdampferdruck und Federkraft aus, sodass der Verdampfer gen\u00fcgend K\u00e4ltemittel f\u00fcr die aktuelle Last erh\u00e4lt, w\u00e4hrend Dampf den Ausgang verl\u00e4sst, bevor er den Verdichter erreicht. Eine korrekte TEV-Auswahl erfordert mehr als die Rohrgr\u00f6\u00dfe: K\u00e4ltemittel, Leistung, Verdampfungstemperatur, Kondensationsbedingungen, Druckabfall, Ausgleichsmethode, Verteilereinrichtung, F\u00fcllung des F\u00fchlers, Anschlussart und das Inbetriebnahme-\u00dcberhitzungsziel m\u00fcssen best\u00e4tigt werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000003 elementor-widget elementor-widget-text-editor\" data-id=\"h000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dieser Leitfaden richtet sich an K\u00e4lteingenieure, OEM-Eink\u00e4ufer, Auftragnehmer, H\u00e4ndler und Projektteams, die ein neues Ventil oder einen Ersatz vergleichen. Er trennt das Funktionsprinzip von den Auswahl- und Installationsentscheidungen, die bestimmen, ob das Ventil im fertigen System stabil regelt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000004 elementor-widget elementor-widget-heading\" data-id=\"h000004\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-a-thermostatic-expansion-valve-does\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was ein thermostatisches Expansionsventil macht<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000005 elementor-widget elementor-widget-text-editor\" data-id=\"h000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein TEV ist ein Drossel- und Dosierorgan zwischen der Fl\u00fcssigkeitsleitung und dem Verdampfer. Es erzeugt einen Druckabfall, senkt die S\u00e4ttigungstemperatur des K\u00e4ltemittels und regelt den Massenstrom in den Verdampfer. Das Ventil reagiert auf den Zustand am Verdampferausgang, anstatt sich einfach um einen festen Prozentsatz zu \u00f6ffnen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000006 elementor-widget elementor-widget-text-editor\" data-id=\"h000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare Tabelle thermostatisches Expansionsventil 1\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Frage des K\u00e4ufers<\/th>\n<th>Praktische TEV-Antwort<\/th>\n<th>Warum es bei einer RFQ wichtig ist<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Was regelt es?<\/td>\n<td>K\u00e4ltemittelmassenstrom in einen Direktverdampfer<\/td>\n<td>Das Ventil muss zur Last, zum K\u00e4ltemittel und zu den Betriebstemperaturen passen<\/td>\n<\/tr>\n<tr>\n<td>Welches Signal nutzt es?<\/td>\n<td>Austrittstemperatur und Verdampferdruck, ausgedr\u00fcckt als \u00dcberhitzung<\/td>\n<td>Die Position von F\u00fchler und Ausgleichsleitung muss definiert werden<\/td>\n<\/tr>\n<tr>\n<td>Wogegen sch\u00fctzt es?<\/td>\n<td>Fl\u00fcssigkeitsschlag bei korrekter Anwendung und Einstellung<\/td>\n<td>Schlechter F\u00fchlerkontakt, falsche F\u00fcllung oder \u00dcberdosierung k\u00f6nnen dennoch einen Verdichter besch\u00e4digen<\/td>\n<\/tr>\n<tr>\n<td>Ist es fest oder modulierend?<\/td>\n<td>Es moduliert die \u00d6ffnung je nach Last und \u00dcberhitzung<\/td>\n<td>Kapazit\u00e4ts- und Druckabfalldaten werden f\u00fcr eine stabile Regelung ben\u00f6tigt<\/td>\n<\/tr>\n<tr>\n<td>Wo ist es installiert?<\/td>\n<td>Im Fl\u00fcssigkeitszulauf nahe dem Verdampfer-Einlass<\/td>\n<td>Verteileranordnung und Wartungszugang beeinflussen die Installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000007 elementor-widget elementor-widget-text-editor\" data-id=\"h000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Wort \u201cthermostatisch\u201d bezieht sich auf das temperaturabh\u00e4ngige Element, nicht auf einen Raumthermostaten. Ein TXV stellt nicht direkt die Raumtemperatur, die Verdichterstufung oder die Abtauzeit ein. Diese Funktionen geh\u00f6ren zum \u00fcbergeordneten K\u00e4lteregelungssystem. F\u00fcr diese Abgrenzung siehe die <a href=\"https:\/\/domirefrigeration.com\/de\/kaltesteuerungen-leitfaden\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">K\u00e4ltesteuerungen-Leitfaden<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000008 elementor-widget elementor-widget-heading\" data-id=\"h000008\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-a-thermostatic-expansion-valve-works\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie ein thermostatisches Expansionsventil funktioniert<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000009 elementor-widget elementor-widget-image\" data-id=\"h000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance.webp\" class=\"attachment-full size-full wp-image-7058\" alt=\"Schnittansicht eines K\u00e4lteventils mit internen Komponenten und Str\u00f6mungswegen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptdarstellung: Schnittzeichnung eines thermostatischen Expansionsventils mit Membran, F\u00fchlerelement, Feder, D\u00fcse und K\u00e4ltemittelflussweg.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000a elementor-widget elementor-widget-text-editor\" data-id=\"h00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Ventil verf\u00fcgt \u00fcber ein F\u00fchlerelement, eine F\u00fchlerbirne, ein Kapillarrohr, eine Membran, eine Feder, einen Ventilsitz, eine D\u00fcse und einen Ausgleichskanal oder -anschluss. Im station\u00e4ren Zustand wirken drei Hauptkr\u00e4fte im Gleichgewicht:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000b elementor-widget elementor-widget-text-editor\" data-id=\"h00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare Tabelle thermostatisches Expansionsventil 2\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Kraft<\/th>\n<th>Quelle<\/th>\n<th>Richtung auf die Membran<\/th>\n<th>Betriebswirkung<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>F\u00fchlerdruck<\/td>\n<td>Fl\u00fcssigkeit in der F\u00fchlerbirne reagiert auf die Saugleitungstemperatur<\/td>\n<td>\u00d6ffnet das Ventil<\/td>\n<td>H\u00f6here gemessene Temperatur erh\u00f6ht im Allgemeinen die \u00d6ffnungskraft<\/td>\n<\/tr>\n<tr>\n<td>Verdampferdruck<\/td>\n<td>Druck, der durch einen internen oder externen Ausgleich \u00fcbertragen wird<\/td>\n<td>Schlie\u00dft das Ventil<\/td>\n<td>Ver\u00e4ndert sich mit dem Verdampfungsdruck und dem Druckabfall durch den Verdampfer<\/td>\n<\/tr>\n<tr>\n<td>Federdruck<\/td>\n<td>\u00dcberhitzungseinstellfeder<\/td>\n<td>Schlie\u00dft das Ventil<\/td>\n<td>Bestimmt den statischen Anteil der \u00dcberhitzungseinstellung<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000c elementor-widget elementor-widget-text-editor\" data-id=\"h00000c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das vereinfachte Gleichgewicht ist <strong>F\u00fchlerdruck = Verdampferdruck + Federkraft<\/strong>. Wenn die Last steigt, neigt der Verdampferausgang dazu, w\u00e4rmer zu werden und der F\u00fchlerdruck steigt. Das Membran bewegt sich in Richtung \u00d6ffnung und l\u00e4sst mehr Fl\u00fcssigkeit zu. Wenn der Ausgang abk\u00fchlt und die \u00dcberhitzung sinkt, gewinnen die Schlie\u00dfkr\u00e4fte das Gleichgewicht zur\u00fcck und das Ventil reduziert den Durchfluss.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000d elementor-widget elementor-widget-text-editor\" data-id=\"h00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Reaktion ist der Grund, warum ein TXV wechselnde Lasten effektiver verfolgen kann als ein festes Drosselventil. Das bedeutet jedoch nicht, dass das Ventil jedes Systemproblem beheben kann. Eine unterversorgte Fl\u00fcssigkeitsleitung, ein verstopfter Filtertrockner, unzureichende Unterk\u00fchlung, falsche K\u00e4ltemittelf\u00fcllung, schlechter Luftstrom oder ein falsch installierter F\u00fchler k\u00f6nnen alle als Dosierventilproblem erscheinen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000e elementor-widget elementor-widget-text-editor\" data-id=\"h00000e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der <a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/R26\/SI\/r26_ch11\/r26_ch11_si.aspx\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">ASHRAE Kapitel \u00fcber K\u00e4lteanlagenregelung<\/a> beschreibt das gleiche Druckgleichgewicht und unterscheidet statische, \u00d6ffnungs- und Betriebs\u00fcberhitzung. Die <a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/how-thermostatic-expansion-valves-work\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss TXV Erkl\u00e4rung<\/a> ist ebenfalls n\u00fctzlich f\u00fcr die Schulung von Installations- und Serviceteams.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000f elementor-widget elementor-widget-heading\" data-id=\"h00000f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"superheat-the-control-variable-buyers-must-define\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00dcberhitzung: die Regelgr\u00f6\u00dfe, die K\u00e4ufer definieren m\u00fcssen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000010 elementor-widget elementor-widget-image\" data-id=\"h000010\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement.webp\" class=\"attachment-full size-full wp-image-7057\" alt=\"Techniker inspiziert industrielle K\u00e4lteanlage mit Messger\u00e4ten und Werkzeugen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptillustration: Deutscher K\u00e4ltetechniker misst Saugdruck und Ausgangstemperatur, um die Verdampfer\u00fcberhitzung zu berechnen.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000011 elementor-widget elementor-widget-text-editor\" data-id=\"h000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00dcberhitzung ist die Differenz zwischen der tats\u00e4chlichen Dampftemperatur an einem Messpunkt und der K\u00e4ltemittels\u00e4ttigungstemperatur, die dem gemessenen Druck an diesem Punkt entspricht. Bei einem TXV-System bewerten Techniker normalerweise die \u00dcberhitzung am Verdampferausgang oder die gesamte Saug\u00fcberhitzung gem\u00e4\u00df dem Anlagendesign und den Vorgaben des Herstellers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000012 elementor-widget elementor-widget-text-editor\" data-id=\"h000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare Tabelle thermostatisches Expansionsventil 3\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Begriff<\/th>\n<th>Bedeutung<\/th>\n<th>Verwendung bei Auswahl oder Inbetriebnahme<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Statische \u00dcberhitzung<\/td>\n<td>\u00dcberhitzung, bei der das Ventil zu \u00f6ffnen beginnt<\/td>\n<td>Teil der Werkseinstellung und Federwahl<\/td>\n<\/tr>\n<tr>\n<td>\u00d6ffnungs\u00fcberhitzung<\/td>\n<td>Zus\u00e4tzliche \u00dcberhitzung, die ben\u00f6tigt wird, um das Ventil in eine n\u00fctzliche Position zu \u00f6ffnen<\/td>\n<td>Verwendet in Hersteller-Kapazit\u00e4tsbewertungen<\/td>\n<\/tr>\n<tr>\n<td>Betriebs\u00fcberhitzung<\/td>\n<td>Statische plus \u00d6ffnungs\u00fcberhitzung bei der Arbeitslast<\/td>\n<td>Der Feldwert zur Beurteilung des Einspeise- und R\u00fccklauf-Risikos<\/td>\n<\/tr>\n<tr>\n<td>Verdampferausgangs\u00fcberhitzung<\/td>\n<td>Temperaturanstieg \u00fcber die S\u00e4ttigung am Verdampferausgang<\/td>\n<td>Hilft zu best\u00e4tigen, dass der Verdampfer versorgt wird, ohne Fl\u00fcssigkeit zur\u00fcckzuf\u00fchren<\/td>\n<\/tr>\n<tr>\n<td>Gesamte Sauggas\u00fcberhitzung<\/td>\n<td>Ausgangs\u00fcberhitzung plus aufgenommene W\u00e4rme in der Saugleitung<\/td>\n<td>N\u00fctzlich zum Schutz des Kompressoreinlasses, aber nicht mit der Verdampferausgangs\u00fcberhitzung verwechseln<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000013 elementor-widget elementor-widget-text-editor\" data-id=\"h000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das genaue Ziel h\u00e4ngt vom K\u00e4ltemittel, Verdampferdesign, Last, Verteiler, Kompressoranforderungen und den Anweisungen des Ger\u00e4teherstellers ab. Vermeiden Sie es, eine universelle Zahl in eine Angebotsanfrage aufzunehmen, wenn die Systembedingungen nicht bekannt sind. Ein Ventil, das nach \u201cmaximaler Reservekapazit\u00e4t\u201d ausgew\u00e4hlt wurde, kann bei unerw\u00fcnschter \u00dcberhitzung laufen und bei geringer Last schlecht modulieren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000014 elementor-widget elementor-widget-heading\" data-id=\"h000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"sensing-bulb-and-equalizer-arrangement\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">F\u00fchler und Ausgleichsanordnung<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000015 elementor-widget elementor-widget-image\" data-id=\"h000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation.webp\" class=\"attachment-full size-full wp-image-7060\" alt=\"Nahaufnahme von K\u00e4lte-Kupferrohren und Isolierung in einem gewerblichen K\u00fchlsystem.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptdarstellung: Thermostatisches Expansionsventil mit F\u00fchler, der an einer sauberen, waagerechten Saugleitung mit Isolierung und externem Ausgleich befestigt ist.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000016 elementor-widget elementor-widget-text-editor\" data-id=\"h000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der F\u00fchler ist der Temperatureingang des Ventils. Er sitzt normalerweise an der Saugleitung am Verdampferausgang, wo er eine repr\u00e4sentative Dampftemperatur erfassen kann. Die Leitung muss sauber sein, der F\u00fchler muss festen thermischen Kontakt haben und die Klemme muss zur Rohrgr\u00f6\u00dfe passen. Eine Isolierung kann erforderlich sein, wenn die Umgebungsluft die Messung verf\u00e4lschen k\u00f6nnte.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000017 elementor-widget elementor-widget-text-editor\" data-id=\"h000017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die F\u00fchlerposition ist Teil der Regelungsauslegung. Ist sie zu nah an einer W\u00e4rmequelle, an einer Stelle, an der sich Fl\u00fcssigkeit sammeln kann, an einem schlecht repr\u00e4sentativen Abschnitt montiert oder locker angebracht, kann das TEV pendeln, unter- oder \u00fcberversorgen. Der Installateur sollte die vom Ventilhersteller erlaubte Ausrichtung und F\u00fchlerposition f\u00fcr den tats\u00e4chlichen Rohrdurchmesser und das K\u00e4ltemittel beachten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000018 elementor-widget elementor-widget-image\" data-id=\"h000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer.webp\" class=\"attachment-full size-full wp-image-7061\" alt=\"Interne und externe Ausgleichswege in einem thermostatischen Expansionsventilkreis mit einem Mehrkreislaufverdampfer\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptdarstellung: Interne und externe Ausgleichswege an einem thermostatischen Expansionsventilkreis mit einem Mehrkreisverdampfer.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000019 elementor-widget elementor-widget-text-editor\" data-id=\"h000019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Interner Ausgleich nimmt den Verdampferdruck durch einen Kanal im Ventilgeh\u00e4use auf. Externer Ausgleich verwendet eine separate Leitung, die am Verdampferausgang oder einem anderen festgelegten Druckpunkt angeschlossen ist. Externer Ausgleich ist oft erforderlich, wenn der Verdampfer, Verteiler oder Saugweg einen erheblichen Druckabfall verursacht. Die Auswahl sollte anhand der Verdampferkreisauslegung best\u00e4tigt werden und nicht aus der Anschlussgr\u00f6\u00dfe abgeleitet werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001a elementor-widget elementor-widget-text-editor\" data-id=\"h00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare thermostatische Expansionsventiltabelle 4\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Anordnung<\/th>\n<th>Geeigneter Ausgangspunkt<\/th>\n<th>Fragen zur Best\u00e4tigung<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Interner Ausgleich<\/td>\n<td>Kompakter Einkreislaufverdampfer mit begrenztem internem Druckverlust<\/td>\n<td>Ist der Druck am Ventilausgang repr\u00e4sentativ f\u00fcr den Verdampferausgang?<\/td>\n<\/tr>\n<tr>\n<td>Externer Ausgleich<\/td>\n<td>Mehrkreislaufverdampfer, Verteiler oder h\u00f6herer Druckverlust<\/td>\n<td>Wo sollte der Ausgleich angeschlossen werden und ist eine Druckmessstelle oder ein Anschluss enthalten?<\/td>\n<\/tr>\n<tr>\n<td>Externer Ausgleich mit Verteiler<\/td>\n<td>Systeme, bei denen der Druckverlust im Verteiler den Regelpunkt beeinflusst<\/td>\n<td>Ber\u00fccksichtigt die ausgew\u00e4hlte Ventilkapazit\u00e4t den Druckverlust im Verteiler?<\/td>\n<\/tr>\n<tr>\n<td>Entfernter oder ungew\u00f6hnlicher F\u00fchlerstandort<\/td>\n<td>Ger\u00e4te mit spezieller Saugleitungsf\u00fchrung oder W\u00e4rmetauschern<\/td>\n<td>Genehmigt der Hersteller den Messpunkt und berechnet f\u00fcr diese Anordnung?<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001b elementor-widget elementor-widget-heading\" data-id=\"h00001b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"txv-types-and-when-to-compare-them\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">TXV-Typen und wann man sie vergleichen sollte<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001c elementor-widget elementor-widget-image\" data-id=\"h00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types.webp\" class=\"attachment-full size-full wp-image-7062\" alt=\"Sammlung industrieller K\u00e4lteventile auf einer Werkbank bei Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptillustration: Vergleich von intern ausgeglichenen, extern ausgeglichenen, balancierten und mit austauschbarer D\u00fcse ausgestatteten thermostatischen Expansionsventilen.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001d elementor-widget elementor-widget-text-editor\" data-id=\"h00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verschiedene TXVs k\u00f6nnen \u00e4hnlich aussehen, aber unterschiedliches Regelverhalten haben. Vergleichen Sie die interne Konstruktion und die Anwendungseinstufung, nicht nur den Ein- und Ausgangsanschluss.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001e elementor-widget elementor-widget-text-editor\" data-id=\"h00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare thermostatische Expansionsventiltabelle 5\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>TXV-Typ oder Merkmal<\/th>\n<th>Was \u00e4ndert sich<\/th>\n<th>Wo es n\u00fctzlich sein kann<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Intern ausgeglichen<\/td>\n<td>Der Verdampferdruck wird durch das Ventilgeh\u00e4use erfasst<\/td>\n<td>Einfache Kreisl\u00e4ufe mit geringem Druckverlust<\/td>\n<\/tr>\n<tr>\n<td>Extern ausgeglichen<\/td>\n<td>Ein spezieller Equalizer misst den Druck am angegebenen nachgelagerten Punkt<\/td>\n<td>Mehrkreisverdampfer und Verteileranwendungen<\/td>\n<\/tr>\n<tr>\n<td>Konventioneller Anschluss<\/td>\n<td>Die Anschlusskr\u00e4fte variieren je nach Druckbedingungen im Ventil<\/td>\n<td>Kleinere oder weniger anspruchsvolle Anwendungen, wenn die Herstellerbewertung dies zul\u00e4sst<\/td>\n<\/tr>\n<tr>\n<td>Ausgeglichener Anschluss<\/td>\n<td>Das Anschlussdesign reduziert den Einfluss von Eingangsdruckschwankungen auf die \u00d6ffnungskraft<\/td>\n<td>Gr\u00f6\u00dfere Kapazit\u00e4t oder wechselnde Druckbedingungen am Kopf, wenn angegeben<\/td>\n<\/tr>\n<tr>\n<td>Universelle F\u00fchlerf\u00fcllung<\/td>\n<td>Breite Betriebsreaktion \u00fcber einen definierten Temperaturbereich<\/td>\n<td>Allgemeine Anwendungen innerhalb des Bereichs des Herstellers der F\u00fcllung<\/td>\n<\/tr>\n<tr>\n<td>Anti-Hunt- oder selektive F\u00fcllung<\/td>\n<td>D\u00e4mpfung oder eine ausgew\u00e4hlte Druck-Temperatur-Reaktion ver\u00e4ndert die Modulation<\/td>\n<td>Systeme, bei denen Schwingungen oder ein enger Betriebsbereich ein Problem darstellen<\/td>\n<\/tr>\n<tr>\n<td>Austauschbare D\u00fcse<\/td>\n<td>Das Geh\u00e4use und die Dosierkapazit\u00e4t k\u00f6nnen mit einem Einsatz abgestimmt werden<\/td>\n<td>Servicebestand und ausgew\u00e4hlte Kapazit\u00e4tsbereiche, wenn vom Hersteller genehmigt<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001f elementor-widget elementor-widget-text-editor\" data-id=\"h00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der <a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/walk-in-coolers-thermostatic-expansion-valves-and-solenoid-valves\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss-Erkl\u00e4rung f\u00fcr K\u00fchlr\u00e4ume<\/a> erkl\u00e4rt, wie F\u00fchler, Membran, Equalizer und Feder zusammenarbeiten. F\u00fcr ein wartungsf\u00e4higes kommerzielles oder industrielles Design sollte auch vermerkt werden, ob das Kraftelement, das Geh\u00e4use, die D\u00fcse und die Anschl\u00fcsse als separate Teile austauschbar sind.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000020 elementor-widget elementor-widget-heading\" data-id=\"h000020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"txv-selection-inputs-for-a-refrigeration-project\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">TXV-Auswahlparameter f\u00fcr ein K\u00e4lteprojekt<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000021 elementor-widget elementor-widget-image\" data-id=\"h000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs.webp\" class=\"attachment-full size-full wp-image-7063\" alt=\"Ingenieur analysiert Daten der K\u00e4lteanlage in der Einrichtung von Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptillustration: Asiatischer HLK-Ingenieur \u00fcberpr\u00fcft K\u00e4ltemittel, Leistung, Verdampfungstemperatur, Druckabfall und Eingaben zur Auswahl des TXV.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000022 elementor-widget elementor-widget-text-editor\" data-id=\"h000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Hersteller oder H\u00e4ndler in Deutschland sollte in der Lage sein, die Auswahl anhand der Informationen in der Anfrage nach Angebot (RFQ) nachzuvollziehen. Geben Sie Betriebspunkte an, anstatt nur die Nennleistung oder Rohrdurchmesser.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000023 elementor-widget elementor-widget-text-editor\" data-id=\"h000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare thermostatische Expansionsventiltabelle 6\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Auswahlparameter<\/th>\n<th>Mindestinformationen, die bereitzustellen sind<\/th>\n<th>Warum der Ventillieferant diese Informationen ben\u00f6tigt<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>K\u00e4ltemittel<\/td>\n<td>Genaue K\u00e4ltemittelbezeichnung sowie Mischung oder Retrofit-Status<\/td>\n<td>Leistung, Druck-Temperatur-Verhalten, F\u00fcllung des F\u00fchlers und Materialien h\u00e4ngen davon ab<\/td>\n<\/tr>\n<tr>\n<td>K\u00e4lteleistung<\/td>\n<td>Erforderliche Leistung bei der geplanten Verdampfungskondition<\/td>\n<td>Das Ventil muss die Last versorgen, ohne sich auf nicht genehmigte Reservekapazit\u00e4t zu verlassen<\/td>\n<\/tr>\n<tr>\n<td>Verdampfungstemperatur<\/td>\n<td>Auslegungs- und erwarteter Betriebsbereich<\/td>\n<td>Bestimmt Druck, \u00dcberhitzungsverhalten und Ventilbewertung<\/td>\n<\/tr>\n<tr>\n<td>Verfl\u00fcssigungsbedingung<\/td>\n<td>Auslegungskondensationstemperatur oder Druckbereich<\/td>\n<td>Beeinflusst verf\u00fcgbaren Druckabfall und Stabilit\u00e4t der Fl\u00fcssigkeitszufuhr<\/td>\n<\/tr>\n<tr>\n<td>Fl\u00fcssigkeitstemperatur und Unterk\u00fchlung<\/td>\n<td>Temperatur am Ventileinlass und verf\u00fcgbare Fl\u00fcssigkeitsunterk\u00fchlung<\/td>\n<td>Best\u00e4tigt, dass die Fl\u00fcssigkeit das Dosierventil ohne Flashgas erreicht<\/td>\n<\/tr>\n<tr>\n<td>Druckverlust<\/td>\n<td>Verf\u00fcgbarer Druckabfall \u00fcber das Ventil am Auslegungspunkt<\/td>\n<td>Leistungstabellen sind an den Druckabfall gebunden, nicht nur an den Anschlussdurchmesser<\/td>\n<\/tr>\n<tr>\n<td>Verdampferkreis<\/td>\n<td>Einzel- oder Mehrfachkreis, Verteilertyp und Druckverlust<\/td>\n<td>Bestimmt Ausgleichsanordnung und Kompatibilit\u00e4t des Verteilers<\/td>\n<\/tr>\n<tr>\n<td>F\u00fchlerf\u00fcllung und \u00dcberhitzung<\/td>\n<td>Erforderliche F\u00fcllung, Familie und Anfangs- oder Werkseinstellung<\/td>\n<td>Steuert den Ansprechbereich und das Verhalten bei geringer Last<\/td>\n<\/tr>\n<tr>\n<td>Anschl\u00fcsse<\/td>\n<td>Einlass-\/Auslassgr\u00f6\u00dfe, Rohrmaterial, B\u00f6rdel-\/L\u00f6t- oder andere Verbindung<\/td>\n<td>Verhindert, dass eine Ma\u00df\u00fcbereinstimmung einen Durchfluss- oder Installationsfehler verdeckt<\/td>\n<\/tr>\n<tr>\n<td>Umgebung und Einsatz<\/td>\n<td>Raum, Prozess, Abk\u00fchlung, Haltebelastung und Regelbereich<\/td>\n<td>Zeigt, ob das Ventil \u00fcber einen gro\u00dfen Lastbereich modulieren muss<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000024 elementor-widget elementor-widget-text-editor\" data-id=\"h000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dimensionieren Sie ein TXV nicht nur anhand des Verdichtervolumens. Das Ventil reagiert auf die Verdampferlast und die Druckbedingungen. Wenn die Anlage in mehreren Betriebsarten arbeitet, listen Sie jede Betriebsart auf und bitten Sie den Lieferanten, die gew\u00e4hlte D\u00fcse und Kapazit\u00e4t \u00fcber den gesamten Betriebsbereich zu pr\u00fcfen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000025 elementor-widget elementor-widget-heading\" data-id=\"h000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"matching-txv-capacity-to-pressure-drop-and-load\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Anpassung der TXV-Kapazit\u00e4t an Druckabfall und Last<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000026 elementor-widget elementor-widget-image\" data-id=\"h000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications.webp\" class=\"attachment-full size-full wp-image-7064\" alt=\"Industrielle K\u00e4lteanlage mit Kompressoren, W\u00e4rmetauschern und Verrohrung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptdarstellung: K\u00e4lteanwendung mit Fl\u00fcssigkeitsleitung, TXV, Verteiler, Verdampfer, Saugleitung, Verdichter und Verfl\u00fcssiger.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000027 elementor-widget elementor-widget-text-editor\" data-id=\"h000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Leistungstabellen variieren in der Regel je nach K\u00e4ltemittel, Verdampfungstemperatur, Kondensations- oder Eintrittsbedingung und Druckabfall. Ein Ventil, das an einem Betriebspunkt ausreichend erscheint, kann an einem anderen instabil sein. Ein zu kleines Ventil kann den Verdampfer bei Spitzenlast verhungern lassen; ein zu gro\u00dfes Ventil kann bei Teillast an Aufl\u00f6sung verlieren und pendeln.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000028 elementor-widget elementor-widget-text-editor\" data-id=\"h000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwenden Sie diese Reihenfolge beim Vergleich von Katalogauswahlen:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000029 elementor-widget elementor-widget-text-editor\" data-id=\"h000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li>Geben Sie die Auslegungskapazit\u00e4t und den Kapazit\u00e4tsbereich an, einschlie\u00dflich Abk\u00fchlung und minimaler Haltebelastung.<\/li>\n<li>Bestimmen Sie die am Ventileinlass verf\u00fcgbare Fl\u00fcssigkeitstemperatur und den Druck.<\/li>\n<li>Berechnen oder ermitteln Sie den verf\u00fcgbaren Druckabfall \u00fcber das Ventil nach Ber\u00fccksichtigung von Leitungs-, Magnetventil-, Verteiler- und Anschlussverlusten.<\/li>\n<li>Verwenden Sie die Leistungstabelle oder das Auswahlwerkzeug des Herstellers f\u00fcr das genaue K\u00e4ltemittel und die Verdampfungsbedingungen.<\/li>\n<li>\u00dcberpr\u00fcfen Sie das ausgew\u00e4hlte Ventil bei niedrigen und hohen Betriebspunkten, einschlie\u00dflich Regelbereich.<\/li>\n<li>Best\u00e4tigen Sie, dass Ventil, D\u00fcse, F\u00fcllung, Ausgleich und Verteiler eine abgestimmte Einheit bilden.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002a elementor-widget elementor-widget-text-editor\" data-id=\"h00002a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der <a href=\"https:\/\/virtualengineer.parker.com\/myprojects\/Sizing\/Sizing?WFID=3f133247-cf7d-f011-b481-000d3a7abe26\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan Virtual Engineer Auswahlwerkzeug<\/a> zeigt, warum f\u00fcr die Auswahl Anwendungsdaten erforderlich sind. Betrachten Sie jedes Katalogergebnis als Startauswahl, bis der Lieferant den endg\u00fcltigen Betriebsbereich best\u00e4tigt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002b elementor-widget elementor-widget-heading\" data-id=\"h00002b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"refrigerant-bulb-charge-and-material-compatibility\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">K\u00e4ltemittel, F\u00fcllung des F\u00fchlers und Materialvertr\u00e4glichkeit<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002c elementor-widget elementor-widget-text-editor\" data-id=\"h00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das K\u00e4ltemittel beeinflusst das Druck-Temperatur-Verhalten, die Leistung, die erforderlichen Materialien und das Ansprechverhalten des thermostatischen Elements. Ein Ersatzventil muss mit dem tats\u00e4chlich im Kreislauf befindlichen K\u00e4ltemittel abgeglichen werden, einschlie\u00dflich einer Umr\u00fcstung oder \u00c4nderung des Gemisches. \u201cGleicher Anschluss\u201d ist kein Nachweis der Kompatibilit\u00e4t.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002d elementor-widget elementor-widget-text-editor\" data-id=\"h00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Best\u00e4tigen Sie diese Punkte in der technischen Einreichung:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002e elementor-widget elementor-widget-text-editor\" data-id=\"h00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>K\u00e4ltemittelbezeichnung und ob das System von einem anderen K\u00e4ltemittel umgestellt wurde.<\/li>\n<li>Zugelassene F\u00fchlerf\u00fcllung oder Leistungselement f\u00fcr den Verdampfungstemperaturbereich.<\/li>\n<li>Kompatibilit\u00e4t von Ventilgeh\u00e4use, Sitz, Membran, Dichtungen und Dichtungen.<\/li>\n<li>Druckfestigkeit und zul\u00e4ssiger Betriebsdruck f\u00fcr Hoch- und Niederdruckseite.<\/li>\n<li>\u00d6l- und Verschmutzungszustand, insbesondere nach einem Verdichterausfall oder -durchbrennen.<\/li>\n<li>Ob das Ventil einen Filtertrockner, ein Einlasssieb oder ein Reinigungsverfahren stromaufw\u00e4rts ben\u00f6tigt.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002f elementor-widget elementor-widget-text-editor\" data-id=\"h00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/50825\/AX266348279899en-000101.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss Monteurhinweise<\/a> beschreiben Sie den Druckausgleich und die Rolle der Feder bei der Einstellung des \u00dcberhitzungsgrades. F\u00fcr die endg\u00fcltige Auswahl gelten der aktuelle Katalog und die Anwendungsdaten des Ventilherstellers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000030 elementor-widget elementor-widget-heading\" data-id=\"h000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"common-txv-symptoms-and-diagnostic-order\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufige TXV-Symptome und Diagnoseablauf<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000031 elementor-widget elementor-widget-image\" data-id=\"h000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms.webp\" class=\"attachment-full size-full wp-image-7065\" alt=\"Techniker inspiziert gewerbliche K\u00e4lteeinheit mit Diagnosewerkzeugen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptabbildung: Asiatischer Servicetechniker diagnostiziert ein K\u00fchlsystem mit Manometern, Messf\u00fchlern, Verdampferfrost, Filtertrockner und TXV.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000032 elementor-widget elementor-widget-text-editor\" data-id=\"h000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein System-Symptom beweist selten, dass das TXV selbst defekt ist. Verwenden Sie eine feste Diagnose-Reihenfolge, damit eine blockierte Fl\u00fcssigkeitsleitung oder eine falsche F\u00fcllmenge nicht mit einem defekten Ventil verwechselt wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000033 elementor-widget elementor-widget-text-editor\" data-id=\"h000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare thermostatische Expansionsventiltabelle 7\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Beobachtetes Symptom<\/th>\n<th>M\u00f6gliche TXV- oder Systemursachen<\/th>\n<th>Pr\u00fcfungen vor dem Austausch<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Niedrige Verdampferleistung und hohe Austritts\u00fcberhitzung<\/td>\n<td>Unterversorgtes Ventil, niedriger Fl\u00fcssigkeitsdruck, Flashgas, blockierter Trockner, geringe F\u00fcllmenge, F\u00fchler misst nicht<\/td>\n<td>Pr\u00fcfen Sie Fl\u00fcssigkeitsunterk\u00fchlung, Schauglas (falls vorhanden), Druckabfall, F\u00fchlerkontakt und Ausgleichsleitung<\/td>\n<\/tr>\n<tr>\n<td>Niedrige \u00dcberhitzung oder R\u00fccklaufgefahr<\/td>\n<td>\u00dcberf\u00fctterung, falsche F\u00fcllung des F\u00fchlers, loser F\u00fchler, falsche Einstellung, geringe Last, Verteilerproblem<\/td>\n<td>Messpunkt, F\u00fchlerinstallation, Last, K\u00e4ltemittelf\u00fcllung und Kompressorschutz \u00fcberpr\u00fcfen<\/td>\n<\/tr>\n<tr>\n<td>Schwankende \u00dcberhitzung<\/td>\n<td>Zu gro\u00dfes Ventil, instabiler Druckabfall, schlechte F\u00fchlerposition, inkompatible F\u00fcllung, intermittierende Fl\u00fcssigkeitszufuhr<\/td>\n<td>\u00dcberhitzung \u00fcber die Zeit aufzeichnen und Einlasszustand sowie Last\u00e4nderungen \u00fcberpr\u00fcfen<\/td>\n<\/tr>\n<tr>\n<td>Frost am Ventil oder Einlass<\/td>\n<td>Druckabfall und Ausgasung, Feuchtigkeit, Verstopfung oder abnormale Niederdruckseite<\/td>\n<td>Filtertrockner, Fl\u00fcssigkeitstemperatur, Druckwerte und K\u00e4ltemittelzustand pr\u00fcfen<\/td>\n<\/tr>\n<tr>\n<td>Keine Reaktion auf Einstellung<\/td>\n<td>Defektes Kraftelement, festsitzende Nadel, blockierter Ausgleich, falsche Einstellrichtung oder ein anderer Systemfehler<\/td>\n<td>Herstellervorschrift befolgen und Druck- sowie Temperaturmessger\u00e4te \u00fcberpr\u00fcfen<\/td>\n<\/tr>\n<tr>\n<td>Funktioniert bei einer Last, versagt aber bei einer anderen<\/td>\n<td>Kapazit\u00e4ts-, F\u00fcllungs- oder Druckabfallabweichung \u00fcber den Betriebsbereich<\/td>\n<td>Auswahlpunkte f\u00fcr geringe und maximale Last erneut \u00fcberpr\u00fcfen<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000034 elementor-widget elementor-widget-text-editor\" data-id=\"h000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Drehen Sie den Einstellstift nicht wiederholt, ohne die urspr\u00fcngliche Position zu notieren und das System stabilisieren zu lassen. Eine zu einem Zeitpunkt gemessene Druck-Temperatur-Anzeige kann eine schwankende oder intermittierende Bedingung verbergen. Wenn ein Kompressor R\u00fccklauf oder Ausfall hatte, sollten \u00d6l- und Systemsauberkeitspr\u00fcfungen in den Wartungsplan aufgenommen werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000035 elementor-widget elementor-widget-heading\" data-id=\"h000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"installation-details-that-affect-txv-performance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Installationsdetails, die die Leistung des TXV beeinflussen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000036 elementor-widget elementor-widget-image\" data-id=\"h000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation.webp\" class=\"attachment-full size-full wp-image-7066\" alt=\"Industrielle K\u00e4lteanlage mit Kupferrohren und K\u00fchleinheiten bei Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptabbildung: Saubere Installation des thermostatischen Expansionsventils nahe dem Verdampfer mit kurzer Fl\u00fcssigkeitszufuhr, Verteiler und abgest\u00fctztem Rohr.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000037 elementor-widget elementor-widget-text-editor\" data-id=\"h000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Befolgen Sie das Installationsmerkblatt des Ventilherstellers und die Ger\u00e4tezeichnung. <a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Sporlan\/Sporlan-pdf-files\/Sporlan-pdf-010\/10-11.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Sporlan Installationsmerkblatt<\/a> betont Ventilposition, N\u00e4he zum Verteiler, Abst\u00fctzung sowie korrekte Ausgleichs- und F\u00fchlerinstallation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000038 elementor-widget elementor-widget-text-editor\" data-id=\"h000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Installationspr\u00fcfungen sollten Folgendes umfassen:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000039 elementor-widget elementor-widget-text-editor\" data-id=\"h000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Montieren Sie das Ventil so nah wie m\u00f6glich am Verdampfer, wie es das Schaltungsdesign erlaubt.<\/li>\n<li>Halten Sie die Leitung zwischen Ventil und Verteiler kurz und frei von unn\u00f6tigen B\u00f6gen oder Einschr\u00e4nkungen.<\/li>\n<li>Sch\u00fctzen Sie das Ventilgeh\u00e4use und das Kraftelement vor \u00fcberm\u00e4\u00dfiger L\u00f6tw\u00e4rme.<\/li>\n<li>Montieren Sie den F\u00fchler auf einer sauberen, repr\u00e4sentativen Saugleitungsoberfl\u00e4che mit der angegebenen Klemme und Ausrichtung.<\/li>\n<li>Befestigen und isolieren Sie den F\u00fchler dort, wo es der Hersteller oder das Anlagendesign verlangt.<\/li>\n<li>F\u00fchren Sie den externen Ausgleich zum angegebenen Druckpunkt, ohne unbeabsichtigte Einschr\u00e4nkungen oder \u00d6lansammlungen.<\/li>\n<li>St\u00fctzen Sie gr\u00f6\u00dfere Ventile und Leitungen ab, damit Vibrationen die Verbindungen nicht belasten.<\/li>\n<li>Halten Sie Feuchtigkeit, Schmutz, L\u00f6tablagerungen und offene Luft vom Kreislauf fern.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003a elementor-widget elementor-widget-text-editor\" data-id=\"h00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn ein Magnetventil, Handventil, Verteiler, Saugakkumulator oder W\u00e4rmetauscher um das TXV platziert wird, zeigen Sie dies im Rohrleitungsdiagramm und ber\u00fccksichtigen Sie den Druckabfall bei der Auswahl.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003b elementor-widget elementor-widget-heading\" data-id=\"h00003b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"commissioning-and-superheat-verification\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Inbetriebnahme und \u00dcberpr\u00fcfung des \u00dcberhitzungsgrades<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003c elementor-widget elementor-widget-image\" data-id=\"h00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning.webp\" class=\"attachment-full size-full wp-image-7067\" alt=\"Asiatischer Inbetriebnahme-Ingenieur dokumentiert Saugdruck, Rohrtemperatur, \u00dcberhitzung und Lastbedingungen auf einem K\u00e4ltepr\u00fcfblatt\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptillustration: Deutscher Inbetriebnahme-Ingenieur dokumentiert Saugdruck, Rohrtemperatur, \u00dcberhitzung und Lastbedingungen auf einem K\u00e4ltepr\u00fcfblatt.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003d elementor-widget elementor-widget-text-editor\" data-id=\"h00003d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Inbetriebnahme sollte eine stabile Ausgangsbasis schaffen, bevor das TXV eingestellt wird. Notieren Sie das K\u00e4ltemittel, Au\u00dfen- oder Anlagenbedingungen, Raum- oder Prozesslast, Verdampfer- und Saugdr\u00fccke, relevante Temperaturen, Zustand der Fl\u00fcssigkeitsleitung, Kompressorstatus und Abtauzustand.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003e elementor-widget elementor-widget-text-editor\" data-id=\"h00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare thermostatische Expansionsventiltabelle 8\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Inbetriebnahmeschritt<\/th>\n<th>Aufzeichnung<\/th>\n<th>Entscheidung<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Best\u00e4tigen Sie den Kreislauf<\/td>\n<td>K\u00e4ltemittel, Ventilmodell, D\u00fcse, F\u00fchlerf\u00fcllung, Ausgleich und Rohrleitungsorientierung<\/td>\n<td>Lehnen Sie eine Nicht\u00fcbereinstimmung vor der Einstellung ab<\/td>\n<\/tr>\n<tr>\n<td>Best\u00e4tigen Sie die Fl\u00fcssigkeitszufuhr<\/td>\n<td>Fl\u00fcssigkeitstemperatur, Unterk\u00fchlung, Druck am Ventileinlass und Zustand des Filtertrockners<\/td>\n<td>Korrigieren Sie zuerst Flashgas oder Einschr\u00e4nkung<\/td>\n<\/tr>\n<tr>\n<td>Messung am Verdampferausgang<\/td>\n<td>Druck und Temperatur am angegebenen Messpunkt<\/td>\n<td>Berechnung des vorgesehenen \u00dcberhitzungswerts<\/td>\n<\/tr>\n<tr>\n<td>Stabilit\u00e4t beobachten<\/td>\n<td>Messwerte w\u00e4hrend Abk\u00fchlung, Haltebetrieb und Mindestlast<\/td>\n<td>Erkennen von Pendeln oder schlechter Regelbarkeit<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00fcfung am Kompressoreinlass<\/td>\n<td>Saugleitungstemperatur, Druck und Herstellervorgaben<\/td>\n<td>Best\u00e4tigung, dass der Kompressor gesch\u00fctzt ist<\/td>\n<\/tr>\n<tr>\n<td>Nur bei Bedarf einstellen<\/td>\n<td>Richtung, Menge, zul\u00e4ssige Stabilisierungszeit und Endwerte<\/td>\n<td>Nachvollziehbare Endstellung dokumentieren<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003f elementor-widget elementor-widget-text-editor\" data-id=\"h00003f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die \u00dcberhitzungsmessung erfordert eine Druckmessung, die mit der richtigen K\u00e4ltemitteldruck-Temperatur-Beziehung umgerechnet wird, sowie eine Temperaturmessung an der richtigen Rohrleitungsstelle. Vergleichen Sie nicht eine Saugleitungstemperatur, die mehrere Meter vom Verdampfer entfernt ist, mit einem Zielwert am Verdampferausgang, ohne den W\u00e4rmegewinn der Leitung zu ber\u00fccksichtigen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000040 elementor-widget elementor-widget-heading\" data-id=\"h000040\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-to-include-in-a-txv-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was in eine TXV-Anfrage aufgenommen werden sollte<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000041 elementor-widget elementor-widget-image\" data-id=\"h000041\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq.webp\" class=\"attachment-full size-full wp-image-7068\" alt=\"Zwei Ingenieure pr\u00fcfen technische Blaupausen in einer modernen industriellen Umgebung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptabbildung: K\u00e4ufer und Ingenieur pr\u00fcfen eine Anfrage f\u00fcr ein thermostatisches Expansionsventil mit Rohrleitungszeichnung, Typenschild und Komponentenprobe.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000042 elementor-widget elementor-widget-text-editor\" data-id=\"h000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine aussagekr\u00e4ftige Anfrage erm\u00f6glicht es Lieferanten, vergleichbare Ventile zu bewerten und fehlende technische Angaben fr\u00fchzeitig zu erkennen. F\u00fcgen Sie das R&amp;I-Flie\u00dfbild oder die Rohrleitungsskizze bei und markieren Sie die Messpunkte.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000043 elementor-widget elementor-widget-text-editor\" data-id=\"h000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Scrollbare thermostatische Expansionsventiltabelle 9\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Anfragefeld<\/th>\n<th>Beispiel f\u00fcr einen n\u00fctzlichen Eintrag<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Anwendung<\/td>\n<td>K\u00fchlraum f\u00fcr mittlere Temperaturen, Tiefk\u00fchlraum, Prozessk\u00fchler oder W\u00e4rmepumpenkreis<\/td>\n<\/tr>\n<tr>\n<td>K\u00e4ltemittel<\/td>\n<td>Genaue Bezeichnung, Mischung oder Retrofit-Hinweis und ggf. \u00d6ltyp<\/td>\n<\/tr>\n<tr>\n<td>Leistung<\/td>\n<td>Auslegungsleistung mit Einheiten und erforderlichem Betriebsbereich<\/td>\n<\/tr>\n<tr>\n<td>Verdampfungsbedingung<\/td>\n<td>Auslegungsverdampfungstemperatur und erwarteter Bereich<\/td>\n<\/tr>\n<tr>\n<td>Verfl\u00fcssigungsbedingung<\/td>\n<td>Auslegungskondensationstemperatur oder -druck und Umgebungstemperaturbereich<\/td>\n<\/tr>\n<tr>\n<td>Fl\u00fcssigkeitszustand<\/td>\n<td>Fl\u00fcssigkeitstemperatur, Unterk\u00fchlung und Druck am TXV-Einlass<\/td>\n<\/tr>\n<tr>\n<td>Ventildruckabfall<\/td>\n<td>Verf\u00fcgbarer Druckabfall nach Verlusten vor und nach dem Ventil<\/td>\n<\/tr>\n<tr>\n<td>Verdampferkreis<\/td>\n<td>Kreisanzahl, Verteiler, Kreisdruckabfall und Bedarf an externem Ausgleich<\/td>\n<\/tr>\n<tr>\n<td>Ventilaufbau<\/td>\n<td>Geh\u00e4usematerial, ausgeglichene oder konventionelle \u00d6ffnung, austauschbare D\u00fcse und Ersatzteile<\/td>\n<\/tr>\n<tr>\n<td>Anschl\u00fcsse<\/td>\n<td>Einlass-\/Auslassgr\u00f6\u00dfe, Anschlussart, Ausrichtung und Rohrmaterial<\/td>\n<\/tr>\n<tr>\n<td>Dokumentation<\/td>\n<td>Leistungstabelle, Kompatibilit\u00e4tserkl\u00e4rung, Montageanleitung, Ersatzteile und Pr\u00fcfprotokolle<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000044 elementor-widget elementor-widget-text-editor\" data-id=\"h000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fragen Sie nach dem vom Lieferanten ausgew\u00e4hlten Modell, der D\u00fcse, F\u00fcllung, Ausgleichsanordnung, Nennleistung unter Ihren Bedingungen sowie etwaigen minimalen oder maximalen Betriebsgrenzen. \u201cTXV, 7\/8 Zoll\u201d ist keine vollst\u00e4ndige Einkaufsspezifikation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000045 elementor-widget elementor-widget-heading\" data-id=\"h000045\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"quality-and-incoming-inspection-checklist\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qualit\u00e4ts- und Wareneingangspr\u00fcfliste<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000046 elementor-widget elementor-widget-image\" data-id=\"h000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection.webp\" class=\"attachment-full size-full wp-image-7069\" alt=\"Asiatischer Qualit\u00e4tspr\u00fcfer kontrolliert TXV-Geh\u00e4usemarkierungen, F\u00fchler, Kapillarrohr, Anschl\u00fcsse und Verpackung\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptabbildung: Asiatischer Qualit\u00e4tspr\u00fcfer kontrolliert TXV-Geh\u00e4usekennzeichnungen, F\u00fchler, Kapillarrohr, Anschl\u00fcsse und Verpackung.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000047 elementor-widget elementor-widget-text-editor\" data-id=\"h000047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Vor der Montage das gelieferte Ventil mit der freigegebenen Einreichung und Packliste vergleichen. Die Pr\u00fcfung sollte auf das Projekt oder die Ger\u00e4tenummer r\u00fcckverfolgbar sein.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000048 elementor-widget elementor-widget-text-editor\" data-id=\"h000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Modell, D\u00fcse, F\u00fcllcode, K\u00e4ltemittelkompatibilit\u00e4t und Anschlussgr\u00f6\u00dfen best\u00e4tigen.<\/li>\n<li>Geh\u00e4usekennzeichnungen, Dichtungen, Kappen, F\u00fchler, Kapillarrohr, Ausgleichsanschluss und mitgeliefertes Zubeh\u00f6r pr\u00fcfen.<\/li>\n<li>Sicherstellen, dass die Schutzkappen bis zur Montage des Kreises an Ort und Stelle bleiben.<\/li>\n<li>Die erhaltenen Ma\u00dfe und die Durchflussrichtung mit der Zeichnung vergleichen.<\/li>\n<li>Vor der Annahme Sch\u00e4den, Korrosion, Verunreinigungen oder verbogenes Kapillarrohr dokumentieren.<\/li>\n<li>Bewahren Sie das Herstellerdatenblatt und die Montageanleitung bei den Ger\u00e4teunterlagen auf.<\/li>\n<li>Nach der Installation erfassen Sie Druck- und Temperaturwerte als Inbetriebnahme-Basislinie.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000049 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"h000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/de\/kontakt\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Domi-Kontaktseite<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004a elementor-widget elementor-widget-heading\" data-id=\"h00004a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufig gestellte Fragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004b elementor-widget elementor-widget-heading\" data-id=\"h00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-is-the-main-function-of-a-thermostatic-expansion-valve\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was ist die Hauptfunktion eines thermostatischen Expansionsventils?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004c elementor-widget elementor-widget-text-editor\" data-id=\"h00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein thermostatisches Expansionsventil regelt den Fl\u00fcssigkeitsk\u00e4ltemittelstrom in einen Direktverdampfer in Abh\u00e4ngigkeit von der \u00dcberhitzung am Austritt. Es hilft, den Verdampfer aktiv zu halten und begrenzt die Wahrscheinlichkeit, dass Fl\u00fcssigkeit durch die Saugleitung zur\u00fcckkehrt, wenn das Ventil korrekt ausgew\u00e4hlt, installiert und in Betrieb genommen wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004d elementor-widget elementor-widget-heading\" data-id=\"h00004d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-does-a-txv-maintain-superheat\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wie h\u00e4lt ein TEV den \u00dcberhitzungsgrad aufrecht?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004e elementor-widget elementor-widget-text-editor\" data-id=\"h00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die F\u00fchlerelement erzeugt durch die Saugleitungstemperatur eine \u00d6ffnungskraft. Der Verdampferdruck und die Feder erzeugen Schlie\u00dfkr\u00e4fte. Ihr Gleichgewicht bewegt die Membran und ver\u00e4ndert die Drossel\u00f6ffnung, wenn sich die Last und die Austritts\u00fcberhitzung \u00e4ndern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004f elementor-widget elementor-widget-heading\" data-id=\"h00004f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"should-i-use-an-internal-or-external-equalizer\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sollte ich einen internen oder externen Ausgleich verwenden?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000050 elementor-widget elementor-widget-text-editor\" data-id=\"h000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwenden Sie das Verdampfer- und Verteiler-Druckabfall-Design zur Entscheidungsfindung. Ein intern ausgeglichenes Ventil eignet sich f\u00fcr einen kompakten Kreislauf mit begrenztem Druckabfall. Ein extern ausgeglichenes Ventil wird h\u00e4ufig in Betracht gezogen, wenn der Druckverlust durch einen Verteiler oder einen Mehrkreislauf-Verdampfer bedeutet, dass der Druck am Ventilgeh\u00e4use nicht repr\u00e4sentativ f\u00fcr den Verdampferausgang ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000051 elementor-widget elementor-widget-heading\" data-id=\"h000051\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-select-a-txv-from-pipe-size-alone\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kann ich ein TEV nur anhand der Rohrgr\u00f6\u00dfe ausw\u00e4hlen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000052 elementor-widget elementor-widget-text-editor\" data-id=\"h000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Die Rohrgr\u00f6\u00dfe best\u00e4tigt lediglich eine Anschlussvorgabe, nicht jedoch die erforderliche Drosselkapazit\u00e4t oder das Regelverhalten. Die Auswahl erfolgt anhand des K\u00e4ltemittels, der Last, der Verdampfungs- und Kondensationsbedingungen, des Fl\u00fcssigkeitszustands, des Druckabfalls, der Ausgleichsanordnung, der F\u00fcllung des F\u00fchlers und der Kapazit\u00e4tsdaten des Herstellers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000053 elementor-widget elementor-widget-heading\" data-id=\"h000053\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-causes-a-txv-to-hunt\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was verursacht das Pendeln eines TEVs?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000054 elementor-widget elementor-widget-text-editor\" data-id=\"h000054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Suchen kann durch ein \u00fcberdimensioniertes Ventil, instabilen Fl\u00fcssigkeitseinlass, schlechten Kontakt oder falsche Position des F\u00fchlers, eine ungeeignete F\u00fcllung, Druckabfall\u00e4nderungen, geringe Last oder einen Systemfehler verursacht werden. Zeichnen Sie die \u00dcberhitzung \u00fcber die Zeit auf und \u00fcberpr\u00fcfen Sie die Fl\u00fcssigkeitszufuhr sowie die Installation, bevor Sie die Einstellung \u00e4ndern oder das Ventil ersetzen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000055 elementor-widget elementor-widget-heading\" data-id=\"h000055\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-a-txv-replacement-rfq-include\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was sollte eine TEV-Ersatzanfrage (RFQ) enthalten?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000056 elementor-widget elementor-widget-text-editor\" data-id=\"h000056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Geben Sie das vorhandene Modell und die D\u00fcse an, falls bekannt, das K\u00e4ltemittel, die Kapazit\u00e4t, Verdampfungs- und Kondensationsbedingungen, Fl\u00fcssigkeitstemperatur oder Unterk\u00fchlung, verf\u00fcgbaren Druckabfall, Details zum Verdampferkreis und Verteiler, Ausgleichsmethode, Anschl\u00fcsse, F\u00fchlerf\u00fcllung, Anwendungsbereich und erforderliche Dokumentation an. F\u00fcgen Sie eine Rohrleitungszeichnung hinzu, wenn der Kreislauf mehrere Zweige oder Zubeh\u00f6rteile enth\u00e4lt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000057 elementor-widget elementor-widget-heading\" data-id=\"h000057\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"primary-technical-references\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wichtige technische Referenzen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000058 elementor-widget elementor-widget-text-editor\" data-id=\"h000058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/R26\/SI\/r26_ch11\/r26_ch11_si.aspx\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">ASHRAE Handbuch: K\u00e4ltemittelregelger\u00e4te<\/a><\/li>\n<li><a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/how-thermostatic-expansion-valves-work\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss: Wie thermostatische Expansionsventile funktionieren<\/a><\/li>\n<li><a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/50825\/AX266348279899en-000101.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss: Monteurhinweise: Thermostatische Expansionsventile<\/a><\/li>\n<li><a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Sporlan\/Sporlan-pdf-files\/Sporlan-pdf-010\/10-11.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan: Installationsanleitung f\u00fcr thermostatische Expansionsventile<\/a><\/li>\n<li><a href=\"https:\/\/virtualengineer.parker.com\/myprojects\/Sizing\/Sizing?WFID=3f133247-cf7d-f011-b481-000d3a7abe26\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan: Virtueller Ingenieur Auswahl Expansionsventil<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000059 elementor-widget elementor-widget-heading\" data-id=\"h000059\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-articles\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verwandte Artikel<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000069 e-con-full e-flex e-con e-parent\" data-id=\"h000069\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h00005e e-con-full e-flex e-con e-parent\" data-id=\"h00005e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h00005b e-con-full e-flex e-con e-parent\" data-id=\"h00005b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005a elementor-widget elementor-widget-text-editor\" data-id=\"h00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/de\/teile-des-kuhlsystems\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Teile eines K\u00fchlsystems: Komponentenbezeichnungen, Funktionen und Anwendungen<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h00005d e-con-full e-flex e-con e-parent\" data-id=\"h00005d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005c elementor-widget elementor-widget-text-editor\" data-id=\"h00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/de\/kaltekreislauf\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">K\u00e4ltemittelkreislauf erkl\u00e4rt: Die 4 Phasen und die Rolle der Register<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000063 e-con-full e-flex e-con e-parent\" data-id=\"h000063\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h000060 e-con-full e-flex e-con e-parent\" data-id=\"h000060\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005f elementor-widget elementor-widget-text-editor\" data-id=\"h00005f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/de\/kaltemittelverdichter\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">K\u00e4lteverdichter: Typen, Dimensionierung und OEM-Auswahlleitfaden<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000062 e-con-full e-flex e-con e-parent\" data-id=\"h000062\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000061 elementor-widget elementor-widget-text-editor\" data-id=\"h000061\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/de\/kaltesteuerungen-leitfaden\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Leitfaden f\u00fcr K\u00e4lteregelung: Typen, Funktionen und RFQ-Eingaben<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000068 e-con-full e-flex e-con e-parent\" data-id=\"h000068\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h000065 e-con-full e-flex e-con e-parent\" data-id=\"h000065\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000064 elementor-widget elementor-widget-text-editor\" data-id=\"h000064\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/de\/kaltesteuerung\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">K\u00e4ltesteuerung: Leitfaden zur Auswahl von Temperatur-, Abtau- und Alarmsteuerungen<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000067 e-con-full e-flex e-con e-parent\" data-id=\"h000067\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000066 elementor-widget elementor-widget-text-editor\" data-id=\"h000066\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/de\/leitfaden-zur-auswahl-von-kalteanlagen\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Leitfaden zur Auswahl von K\u00e4lteeinheiten f\u00fcr gewerbliche und OEM-Systeme<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00006a elementor-align-left elementor-widget elementor-widget-button\" data-id=\"h00006a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/de\/kontakt\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Senden Sie Ihre K\u00e4ltezeichnung zur \u00dcberpr\u00fcfung<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie, wie ein thermostatisches Expansionsventil den \u00dcberhitzungsgrad steuert, wie man ein TEV dimensioniert und welche K\u00e4ltemittel-, Last-, Druck- und RFQ-Angaben K\u00e4ufer best\u00e4tigen m\u00fcssen.<\/p>","protected":false},"author":1,"featured_media":7059,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7070","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/comments?post=7070"}],"version-history":[{"count":4,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7070\/revisions"}],"predecessor-version":[{"id":7096,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7070\/revisions\/7096"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media\/7059"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media?parent=7070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/categories?post=7070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/tags?post=7070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}