{"id":7147,"date":"2026-10-06T00:38:24","date_gmt":"2026-10-05T16:38:24","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7147"},"modified":"2026-10-06T00:38:24","modified_gmt":"2026-10-05T16:38:24","slug":"planungsleitfaden-fur-kaltemittelleitungen","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/de\/refrigerant-piping-design-guide\/","title":{"rendered":"Leitfaden f\u00fcr die Auslegung von K\u00e4ltemittelleitungen: Rohrdimensionierung, Verlegung und OEM-Pr\u00fcfungen"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7147\" class=\"elementor elementor-7147\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000060 e-con-full e-flex e-con e-parent\" data-id=\"nr000060\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000002 e-con-full e-flex e-con e-parent\" data-id=\"nr000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000001 elementor-widget elementor-widget-text-editor\" data-id=\"nr000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>K\u00e4ltemittelleitungen verbinden Verdichter, Verfl\u00fcssiger, Expansionseinrichtung und Verdampfer. Dimensionieren und verlegen Sie jeden Abschnitt entsprechend dem gew\u00e4hlten K\u00e4ltemittel, den Betriebsbedingungen, dem Leistungsbereich, der tats\u00e4chlichen Leitungsl\u00e4nge, dem H\u00f6henunterschied und den angeschlossenen Ger\u00e4ten. Die Saugleitung muss bei der niedrigsten erwarteten Last \u00d6l zur\u00fcckf\u00fchren und gleichzeitig den Druckverlust innerhalb der Verdichtergrenzen halten. Die Fl\u00fcssigkeitsleitung muss Fl\u00fcssigkeit ohne Vorverdampfung zum Einspritzorgan leiten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000003 elementor-widget elementor-widget-text-editor\" data-id=\"nr000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Ger\u00e4teanschluss ist eine Anschlussgr\u00f6\u00dfe, keine Feldeitungsangabe. <a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Danfoss-Leitfaden f\u00fcr K\u00fchlraumverrohrung<\/a> behandelt die Leitungsgr\u00f6\u00dfe als Funktion von K\u00e4ltemittel, Leistung, Leitungsl\u00e4nge, H\u00f6henunterschied und Betriebstemperaturen. Verwenden Sie die Daten des ausgew\u00e4hlten Verdichter- und Ger\u00e4teherstellers f\u00fcr die tats\u00e4chliche Einsatzgrenze.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000004 elementor-widget elementor-widget-image\" data-id=\"nr000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop.webp\" class=\"attachment-full size-full wp-image-7136\" alt=\"K\u00fchlraum mit einem Au\u00dfenkondensator, Kompressorverbund, dar\u00fcber liegenden Rohrleitungen und einer Verdampfereinheit.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Generierte System\u00fcbersicht. Es handelt sich nicht um eine Domi-Installation.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000005 elementor-widget elementor-widget-heading\" data-id=\"nr000005\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-main-refrigerant-line-types\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was sind die Haupttypen von K\u00e4ltemittelleitungen?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000006 elementor-widget elementor-widget-text-editor\" data-id=\"nr000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Kompressionsk\u00e4ltesystem hat normalerweise drei Hauptleitungsfunktionen. Komplexe Systeme k\u00f6nnen Abzweigungen, Sammler, Hei\u00dfgas-Abtauleitungen, \u00d6konomizer-Leitungen oder reversible W\u00e4rmepumpenkreisl\u00e4ufe umfassen. Der Leitungsname beschreibt seinen K\u00e4ltemittelzustand und die Str\u00f6mungsrichtung, \u00fcberpr\u00fcfen Sie daher den tats\u00e4chlichen Schaltkreis im Projektschema.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000007 elementor-widget elementor-widget-text-editor\" data-id=\"nr000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Eine Saugleitung leitet Dampf vom Verdampferausgang zum Verdichtereingang. \u00dcberpr\u00fcfen Sie die \u00d6l R\u00fcckf\u00fchrung bei Mindestlast und halten Sie den Sauggru\u00dfdruckabfall innerhalb der Verdichtergrenzen.<\/li>\n<li>Eine Druckleitung leitet Hei\u00dfgas vom Verdichter zum Verfl\u00fcssiger. \u00dcberpr\u00fcfen Sie Druckstufe, Temperatur, Vibration sowie K\u00e4ltemittel- oder \u00d6lmigration.<\/li>\n<li>Eine Fl\u00fcssigkeitsleitung verl\u00e4uft vom Verfl\u00fcssiger oder Sammler zum Expansionsteil. \u00dcberpr\u00fcfen Sie den Druckabfall, damit die Fl\u00fcssigkeit ohne Vorverdampfung das Einspritzorgan erreicht.<\/li>\n<li>Abzweigungen und Sonderleitungen dienen f\u00fcr Sammler, Hei\u00dfgas-Abtauung, \u00d6konomizer oder reversible Kreisl\u00e4ufe. Befolgen Sie das Ger\u00e4teschema und die Anweisungen der jeweiligen Komponente.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000008 elementor-widget elementor-widget-image\" data-id=\"nr000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families.webp\" class=\"attachment-full size-full wp-image-7134\" alt=\"Kommerzieller K\u00e4ltekompressor und W\u00e4rmetauscher, verbunden durch Saug-, Druck- und Fl\u00fcssigkeitsleitungspfade.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptdarstellung. Best\u00e4tigen Sie den tats\u00e4chlichen Kreislauf aus dem Projektschema.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000009 elementor-widget elementor-widget-text-editor\" data-id=\"nr000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine an einem Betriebspunkt ausgew\u00e4hlte Leitung funktioniert m\u00f6glicherweise nicht \u00fcber den gesamten Bereich. <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEM&amp;PDF=AE-105\" target=\"_blank\" rel=\"noopener\">Copelands K\u00e4ltehandbuch<\/a> bespricht die \u00d6l R\u00fcckf\u00fchrung in Abzweig- und Hauptsaugleitungen bei Mindestlast sowie den Druckabfall in Fl\u00fcssigkeits- und Hei\u00dfgasleitungen. Eine Einzeldurchmesserregel kann diese unterschiedlichen Bedingungen nicht abdecken. Den viermufigen Kreislauf und die Rolle der einzelnen W\u00e4rmeaustauscher finden Sie unter <a href=\"https:\/\/domirefrigeration.com\/de\/kaltekreislauf\/\">Leitfaden f\u00fcr den K\u00e4ltemittelkreislauf<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000a elementor-widget elementor-widget-heading\" data-id=\"nr00000a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"which-inputs-determine-refrigerant-line-size\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Welche Eingaben bestimmen die K\u00e4ltemittelleitungsgr\u00f6\u00dfe?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000b elementor-widget elementor-widget-text-editor\" data-id=\"nr00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beginnen Sie mit der Einsatzgrenze, nicht mit dem auf einem Anschluss aufgedruckten Au\u00dfendurchmesser. Notieren Sie die folgenden Daten, bevor Sie ein Rohrschaubild oder ein Auswahltool ausw\u00e4hlen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000c elementor-widget elementor-widget-text-editor\" data-id=\"nr00000c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>K\u00e4ltemittel- und \u00d6ltyp, einschlie\u00dflich aller zugelassenen Alternativen.<\/li>\n<li>Erforderliche K\u00e4lteleistung bei jeder Auslegungsbedingung, nicht nur die Nennleistung.<\/li>\n<li>Verdampfungs- und Verfl\u00fcssigungstemperaturen oder -dr\u00fccke, \u00dcberhitzung und Unterk\u00fchlung, sofern vom Tool gefordert.<\/li>\n<li>Kompressormodell, Leistungsregelungsmethode sowie minimale und maximale Betriebspunkte.<\/li>\n<li>Leitungsfunktion: Saugleitung, Hei\u00dfgasleitung, Fl\u00fcssigkeitsleitung, Hei\u00dfgas oder ein Abzweig.<\/li>\n<li>Tats\u00e4chliche Routenl\u00e4nge, \u00e4quivalente L\u00e4nge von Formst\u00fccken, vertikaler Steigungs- oder Gef\u00e4lleabschnitt sowie der Standort jeder Komponente.<\/li>\n<li>W\u00e4rmepumpen-Umschaltung, Abtauung, Abschaltung und Teillastbedingungen, die die Str\u00f6mungsrichtung oder den Massenstrom \u00e4ndern.<\/li>\n<li>Rohrstockmaterial, Verbindungsmethode, Druck- und Temperaturgrenzen, Isolierung, Halterungen und lokale Vorschriften.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000d elementor-widget elementor-widget-image\" data-id=\"nr00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs.webp\" class=\"attachment-full size-full wp-image-7137\" alt=\"Ingenieur \u00fcberpr\u00fcft einen K\u00e4lteanlagen-Rohrleitungsweg und Ger\u00e4testundenplan neben einem kommerziellen System.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Generierte Kategorienszene, keine Aufzeichnung eines Domi-Projekts.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000e elementor-widget elementor-widget-text-editor\" data-id=\"nr00000e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Das Systemdesign-Handbuch von Danfoss<\/a> f\u00fchrt K\u00e4ltemittel, Leistung, Leitungsl\u00e4nge, H\u00f6henlage und Betriebstemperatur unter den Eingaben f\u00fcr K\u00fchlraumverrohrungen auf. Es trennt zudem die Pr\u00fcfungen f\u00fcr Fl\u00fcssigkeits-, Saug- und Druckleitungen. Verwenden Sie die Anweisungen des ausgew\u00e4hlten Herstellers oder eine zugelassene Auslegungssoftware, um diese Eingaben in eine Kandidatengr\u00f6\u00dfe umzuwandeln. F\u00fcr den Kontext der Kompressorauswahl siehe Domis <a href=\"https:\/\/domirefrigeration.com\/de\/kaltemittelverdichter\/\">K\u00e4lteleitfaden f\u00fcr Kompressoren<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000f elementor-widget elementor-widget-heading\" data-id=\"nr00000f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-size-refrigerant-lines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie dimensionieren Sie K\u00e4ltemittelleitungen?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000010 elementor-widget elementor-widget-text-editor\" data-id=\"nr000010\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwenden Sie f\u00fcr jeden Abschnitt des Systems eine wiederholbare Sequenz. W\u00e4hlen Sie Rohre nicht allein nach der Nennleistung aus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000011 elementor-widget elementor-widget-text-editor\" data-id=\"nr000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li><strong>Legen Sie den Auslegungsfall fest.<\/strong> Best\u00e4tigen Sie K\u00e4ltemittel, Verdampfungs- und Kondensationsbedingungen, K\u00e4lteleistung, Umgebungstemperaturbereich und Betriebsarten.<\/li>\n<li><strong>Zeichnen Sie die Leitungsabschnitte.<\/strong> Markieren Sie Saug-, Fl\u00fcssigkeits-, Druck- und Spezialleitungen separat. Erfassen Sie Abzweigungen, Sammler, vertikale \u00c4nderungen und Ger\u00e4teanschl\u00fcsse.<\/li>\n<li><strong>Messen Sie die Route.<\/strong> Ber\u00fccksichtigen Sie gerade L\u00e4ngen, Formst\u00fccke, H\u00f6henlage und Verlegebeschr\u00e4nkungen. Ein Schema, das die Route wegl\u00e4sst, unterst\u00fctzt m\u00f6glicherweise keine endg\u00fcltige Dimensionierung.<\/li>\n<li><strong>W\u00e4hlen Sie einen Kandidaten im Tool oder in den Tabellen des Ger\u00e4teherstellers aus.<\/strong> Verwenden Sie Daten f\u00fcr das angegebene K\u00e4ltemittel und die Verdichterfamilie. \u00dcbertragen Sie einen Tabellenwert nicht ohne Best\u00e4tigung auf ein anderes K\u00e4ltemittel oder einen anderen Einsatzbereich.<\/li>\n<li><strong>\u00dcberpr\u00fcfen Sie den Druckverlust und den Massenstrom.<\/strong> \u00dcberpr\u00fcfen Sie jede Leitung unter den Auslegungsbedingungen. Die Fl\u00fcssigkeitsleitung muss die Fl\u00fcssigkeitszufuhr zum Expansionsorgan sicherstellen; der Saugdruckverlust beeinflusst die Verdichtereinlassbedingungen.<\/li>\n<li><strong>\u00dcberpr\u00fcfen Sie die \u00d6lr\u00fcckf\u00fchrung bei der niedrigsten zu erwartenden Last.<\/strong> Drehzahlgeregelte Verdichter und gestufte Systeme erfordern eine Teillastpr\u00fcfung. Eine nur f\u00fcr die Vollast ausgelegte Leitung f\u00f6rdert das \u00d6l bei sinkendem Massenstrom m\u00f6glicherweise nicht zuverl\u00e4ssig.<\/li>\n<li><strong>\u00dcberpr\u00fcfen Sie die Installations- und Druckgrenzen.<\/strong> Best\u00e4tigen Sie Rohrmaterial, Druckstufe, Verbindungsmethode, Halterungen, Isolierung, Schwingungsd\u00e4mpfung und geltende Sicherheitsregeln.<\/li>\n<li><strong>Bewahren Sie die Berechnung zusammen mit der Zeichnung auf.<\/strong> Dokumentieren Sie die Werkzeug- oder Herstellerreferenz, die Annahmen, die gew\u00e4hlte Rohrgr\u00f6\u00dfe und den Pr\u00fcfer, damit sp\u00e4tere Ger\u00e4te- oder K\u00e4ltemittel\u00e4nderungen \u00fcberpr\u00fcft werden k\u00f6nnen.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000012 elementor-widget elementor-widget-image\" data-id=\"nr000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff.webp\" class=\"attachment-full size-full wp-image-7138\" alt=\"Konzeptioneller Vergleich alternativer Sauggasrohrdurchmesser zur Verdeutlichung von Geschwindigkeits- und Druckverlust-Kompromissen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Nur Konzeptvergleich. W\u00e4hlen Sie die Rohrgr\u00f6\u00dfe f\u00fcr den tats\u00e4chlichen Betriebsbereich aus.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000013 elementor-widget elementor-widget-text-editor\" data-id=\"nr000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das sinnvolle Ergebnis ist eine dokumentierte Auslegung f\u00fcr den angegebenen Einsatzbereich, keine universelle Tabelle mit Rohrdurchmessern. Wenn sich K\u00e4ltemittel, Verdichterdrehzahlbereich, Verdampfungstemperatur oder Verlegung \u00e4ndern, f\u00fchren Sie die Auslegung erneut durch.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000014 elementor-widget elementor-widget-heading\" data-id=\"nr000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"why-is-the-unit-connection-size-not-always-the-field-line-size\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum entspricht die Gr\u00f6\u00dfe des Ger\u00e4teanschlusses nicht immer der Gr\u00f6\u00dfe der Rohrleitung vor Ort?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000015 elementor-widget elementor-widget-text-editor\" data-id=\"nr000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Verdichter-, Verfl\u00fcssiger- oder Verfl\u00fcssigungssatzanschluss ist eine Komponentenschnittstelle. Die Verbindungsleitung hat ihren eigenen Verlauf, ihre eigene L\u00e4nge, Str\u00f6mungsrate und H\u00f6he. Ein Anschluss und eine Vorortleitung k\u00f6nnen in einer bestimmten Konstruktion denselben Durchmesser haben, aber der Anschluss allein begr\u00fcndet diese Wahl nicht.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000016 elementor-widget elementor-widget-text-editor\" data-id=\"nr000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In einem <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/580178\/AB399636244436en-000301.pdf\" target=\"_blank\" rel=\"noopener\">modellspezifischen Danfoss-Anwendungshandbuch f\u00fcr Verfl\u00fcssigungss\u00e4tze<\/a>, warnt der Hersteller davor anzunehmen, dass die Saug- und Fl\u00fcssigkeitsanschl\u00fcsse des Ger\u00e4ts die richtigen Gr\u00f6\u00dfen f\u00fcr die Verbindungsleitungen sind. Dieses Handbuch fordert auch eine Dimensionierung \u00fcber den gesamten Leistungsbereich des Ger\u00e4ts hinweg. Dies ist ein Anwendungsbeispiel, das jedoch zeigt, warum eine Anschlussabmessung allein nicht die Feldrohrgr\u00f6\u00dfe festlegen kann. Best\u00e4tigen Sie den genehmigten Leitungsplan in den Daten des Ger\u00e4teherstellers vor der Fertigung oder Installation. Betrachten Sie bei einer Zeichnungspr\u00fcfung jeden Anschluss als Schnittstelle und pr\u00fcfen Sie dann den gesamten Verlauf anhand der ausgew\u00e4hlten Ger\u00e4tedaten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000017 elementor-widget elementor-widget-image\" data-id=\"nr000017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs.webp\" class=\"attachment-full size-full wp-image-7139\" alt=\"Kurze Verfl\u00fcssigungssatz-Anschlussstutzen neben separaten bauseitigen Rohrleitungen, die durch einen Anlagenbereich gef\u00fchrt werden.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ein Komponentenanschluss legt nicht die Gr\u00f6\u00dfe der Feldleitung fest.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000018 elementor-widget elementor-widget-text-editor\" data-id=\"nr000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Senden Sie bei einem OEM-Paket Zeichnung, K\u00e4ltemittel, Zielkapazit\u00e4t und Leitungsplan zusammen. Dies gibt dem Pr\u00fcfer den Kontext, um einen Paketanschluss im Hinblick auf den gesamten Verbindungslauf zu bewerten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000019 elementor-widget elementor-widget-heading\" data-id=\"nr000019\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-part-load-systems-change-suction-line-design\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie ver\u00e4ndern Teillastsysteme die Saugfungsleitungsauslegung?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001a elementor-widget elementor-widget-text-editor\" data-id=\"nr00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Teillastbetrieb f\u00fchrt zu einem Auslegungskompromiss. Eine gro\u00dfe Saugleitung kann den Druckverlust bei Vollast verringern, aber die Gasgeschwindigkeit kann bei geringer Leistung oder niedriger Verdichterdrehzahl zu stark abfallen, als dass eine \u00d6lr\u00fcckf\u00fchrung gew\u00e4hrleistet ist. Eine kleinere Leitung kann die Geschwindigkeit bei geringer Last aufrechterhalten, verursacht jedoch bei h\u00f6herem Durchfluss einen gr\u00f6\u00dferen Druckverlust.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001b elementor-widget elementor-widget-text-editor\" data-id=\"nr00001b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Einige Verdichteranwendungen verwenden einen geteilten Steigstrang oder Doppelsteigstrang \u00fcber einen gro\u00dfen Leistungsbereich. Der kleinere Strang kann die \u00d6lr\u00fcckf\u00fchrung bei reduzierter Leistung unterst\u00fctzen; bei h\u00f6herer Last f\u00fchren beide Str\u00e4nge den Massenstrom. Diese Anordnung h\u00e4ngt vom Verdichter und den Betriebsbedingungen ab und ist daher keine Abk\u00fcrzung f\u00fcr Nachr\u00fcstungen. <a href=\"https:\/\/www.bitzer.de\/shared_media\/html\/est-600\/en-GB\/556451979556454155.html\" target=\"_blank\" rel=\"noopener\">Die Rohrleitungs-Richtlinien von BITZER<\/a> beschreiben geteilte Steigstr\u00e4nge f\u00fcr leistungsgeregelte Systeme und die Notwendigkeit, die \u00d6lr\u00fcckf\u00fchrung bei Mindestlast zu \u00fcberpr\u00fcfen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001c elementor-widget elementor-widget-image\" data-id=\"nr00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser.webp\" class=\"attachment-full size-full wp-image-7142\" alt=\"Konzeptioneller getrennter Sauggasanstieg mit gr\u00f6\u00dferen und kleineren vertikalen Abzweigen zwischen gemeinsamen Sammlern.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptionelle Anordnung. Best\u00e4tigen Sie das Design anhand der Verdichter-Anwendungsdaten.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001d elementor-widget elementor-widget-text-editor\" data-id=\"nr00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bitten Sie den Verdichterlieferanten oder Systemplaner um die Best\u00e4tigung von:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001e elementor-widget elementor-widget-text-editor\" data-id=\"nr00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Ob der Verdichter mit fester Drehzahl, gestuften Stufen oder variabler Drehzahl arbeitet.<\/li>\n<li>Der minimale stabile Massenstrom und die Drehzahl.<\/li>\n<li>Die voraussichtliche vertikale Steigung und der Betriebsablauf.<\/li>\n<li>Ob ein einzelner Steigstrang, ein geteilter Steigstrang oder eine andere Anordnung zugelassen ist.<\/li>\n<li>Wie die \u00d6lr\u00fcckf\u00fchrung bei der Inbetriebnahme \u00fcberpr\u00fcft wird.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001f elementor-widget elementor-widget-text-editor\" data-id=\"nr00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00dcbernehmen Sie kein Geschwindigkeitsziel aus einem Handbuch in ein anderes System. Ver\u00f6ffentlichte Werte gelten f\u00fcr den genannten Verdichter, das K\u00e4ltemittel, den Leistungsbereich und die Anweisungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000020 elementor-widget elementor-widget-heading\" data-id=\"nr000020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-material-should-refrigerant-piping-use\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Welches Material sollte f\u00fcr K\u00e4ltemittelleitungen verwendet werden?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000021 elementor-widget elementor-widget-text-editor\" data-id=\"nr000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kupfer-ACR-Rohre sind f\u00fcr Feldanschl\u00fcsse in vielen K\u00e4lteanwendungen \u00fcblich. <a href=\"https:\/\/store.astm.org\/b0280-23.html\" target=\"_blank\" rel=\"noopener\">ASTM B280-23<\/a> spezifiziert nahtlose Kupferrohre f\u00fcr den Klima- und K\u00e4lteanlagenbau im Feld. Die Norm legt weder die Wandst\u00e4rke, den Durchmesser, die Verbindungsmethode noch die Druckstufe f\u00fcr ein bestimmtes System fest.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000022 elementor-widget elementor-widget-text-editor\" data-id=\"nr000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Materialauswahl muss auf das K\u00e4ltemittel, den Druck- und Temperaturbereich, die Komponentenzulassungen, die Verbindungsmethode, die Umgebung und die \u00f6rtlichen Vorschriften abgestimmt sein. CO2-Systeme arbeiten unter Druckbedingungen, die Ger\u00e4te und Rohrleitungen erfordern, die f\u00fcr diese Anwendung ausgelegt sind. A2L-Systeme haben zudem k\u00e4ltemittelspezifische Sicherheits- und Installationsanforderungen. \u00dcberpr\u00fcfen Sie die Rohre und Formst\u00fccke anhand des Auslegungsdrucks und der Anweisungen f\u00fcr das genaue System.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000023 elementor-widget elementor-widget-image\" data-id=\"nr000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure.webp\" class=\"attachment-full size-full wp-image-7140\" alt=\"Kupfer-ACR-Rohrleitungen neben K\u00e4ltemittelventilen und -fittings in einem konzeptionellen Materialvergleich.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Material und Druckstufe m\u00fcssen f\u00fcr die Anwendung spezifiziert werden.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000024 elementor-widget elementor-widget-text-editor\" data-id=\"nr000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine Beschaffungszeichnung sollte die Rohrnorm und das Material angeben, sofern diese bekannt sind. Wenn die Spezifikation unvollst\u00e4ndig ist, f\u00fchren Sie dies als offenen Engineering-Punkt auf, anstatt anzunehmen, dass jedes Kupferrohr oder -fiting funktioniert.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000025 elementor-widget elementor-widget-heading\" data-id=\"nr000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-route-length-and-fittings-affect-pressure-drop\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie beeinflussen Leitungsl\u00e4nge und Fittings den Druckverlust?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000026 elementor-widget elementor-widget-text-editor\" data-id=\"nr000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der Rohrverlauf beeinflusst Druckverlust, K\u00e4ltemittelf\u00fcllung, \u00d6lbewegung, Servicezugang und Installationskosten. Lange Strecken, viele B\u00f6gen, unterdimensionierte Abzweigungen, abrupte Reduzierungen und ung\u00fcnstig platzierte Steigungen k\u00f6nnen das Ergebnis ver\u00e4ndern, das eine Nachschlagelabelle f\u00fcr gerade Rohre nahelegt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000027 elementor-widget elementor-widget-text-editor\" data-id=\"nr000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Halten Sie die Leitungsf\u00fchrungen so kurz, wie es das Anlagenlayout erlaubt. Verwenden Sie die vom Auslegungstool des Herstellers geforderte Methode f\u00fcr Formst\u00fccke und \u00e4quivalente L\u00e4ngen. F\u00fcgen Sie H\u00f6hen\u00e4nderungen und die Abzweigungsgeometrie zum Modell hinzu und \u00fcberpr\u00fcfen Sie dann den ung\u00fcnstigsten Betriebspunkt. Ersetzen Sie die Druckverlustberechnung nicht durch eine visuelle Sch\u00e4tzung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000028 elementor-widget elementor-widget-image\" data-id=\"nr000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length.webp\" class=\"attachment-full size-full wp-image-7141\" alt=\"Gewerbliche K\u00e4lteanlagen, verbunden durch Rohrleitungsf\u00fchrungen mit unterschiedlichen L\u00e4ngen und Richtungs\u00e4nderungen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Beispielhafte Verlegewege. \u00dcberpr\u00fcfen Sie die tats\u00e4chlichen Formst\u00fcck- und H\u00f6henl\u00e4ngen im ausgew\u00e4hlten Tool.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000029 elementor-widget elementor-widget-text-editor\" data-id=\"nr000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Der Rohrleitungsratgeber von Danfoss<\/a> empfiehlt, unn\u00f6tige Richtungs\u00e4nderungen zu minimieren und Durchh\u00e4ngen zu verhindern, das unbeabsichtigte \u00d6lsammler verursachen kann. Halten Sie Wartungsventile, Verdichteranschl\u00fcsse, Schaugl\u00e4ser und abnehmbare Verkleidungen zug\u00e4nglich. Isolieren Sie jede Leitung dort, wo es die Ger\u00e4teanweisungen und Betriebsbedingungen erfordern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002a elementor-widget elementor-widget-heading\" data-id=\"nr00002a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-the-installation-drawing-show\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was sollte die Installationszeichnung zeigen?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002b elementor-widget elementor-widget-text-editor\" data-id=\"nr00002b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine n\u00fctzliche Feldbeschreibung erm\u00f6glicht es dem Installateur, den vorgesehenen Weg zu bauen und zu \u00fcberpr\u00fcfen. Die unten generierte Abbildung zeigt beispielhafte Zeichnungselemente; sie ist nicht ausf\u00fchrungsreif. Listen Sie diese projektspezifischen Punkte auf:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002c elementor-widget elementor-widget-image\" data-id=\"nr00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing.webp\" class=\"attachment-full size-full wp-image-7144\" alt=\"Konzeptionelles K\u00e4ltemittelleitungsschema mit Abzweig, vertikalen \u00c4nderungen, Halterungen und zug\u00e4nglicher Ausr\u00fcstung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptdiagramm, keine ausf\u00fchrungsreife oder bema\u00dfte Zeichnung.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002d elementor-widget elementor-widget-text-editor\" data-id=\"nr00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Str\u00f6mungsrichtung und Leitungsfunktion f\u00fcr jeden Abschnitt.<\/li>\n<li>Rohrwerkstoff, Au\u00dfendurchmesser oder Nennbezeichnung sowie Wandst\u00e4rkenspezifikation, sofern zutreffend.<\/li>\n<li>Formst\u00fccke, Abzweige, Reduzierst\u00fccke, Sammler, Steigleitungen sowie Absperr- oder Wartungskomponenten.<\/li>\n<li>Anschlussorte der Ger\u00e4te und der genehmigte Anschlussplan.<\/li>\n<li>Isolationsgrenzen, St\u00fctzpunkte, Durchdringungen und Details zur Schwingungsd\u00e4mpfung.<\/li>\n<li>Auslegungsdruck und -temperatur, sofern f\u00fcr die Material- und Komponentenauswahl erforderlich.<\/li>\n<li>Besondere Bedingungen f\u00fcr Hei\u00dfgasabtauung, W\u00e4rmepumpenumkehr, Abpumpen (Pump-Down) oder Teillastbetrieb.<\/li>\n<li>Der Revisionsstand der Zeichnung und die Quelle der Auslegungsdaten.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002e elementor-widget elementor-widget-image\" data-id=\"nr00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration.webp\" class=\"attachment-full size-full wp-image-7143\" alt=\"Isolierte und abgest\u00fctzte Kupfer-K\u00e4ltemittelleitungen neben einem Kompressor mit flexiblem Anschluss.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Generiertes Konzeptbild, kein Domi-Installationsnachweis.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002f elementor-widget elementor-widget-text-editor\" data-id=\"nr00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEM&amp;PDF=AE-105\" target=\"_blank\" rel=\"noopener\">Copelands K\u00e4ltehandbuch<\/a> behandelt Rohrunterst\u00fctzungen, \u00d6lsammler, Schwingungen und Rohrschutz. Befolgen Sie die f\u00fcr das Ger\u00e4t und das Projekt festgelegten Abst\u00e4nde der Halterungen und das Verbindungsverfahren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000030 elementor-widget elementor-widget-heading\" data-id=\"nr000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-can-commissioning-checks-confirm-the-piping-design\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie k\u00f6nnen Inbetriebnahme-Pr\u00fcfungen das Rohrleitungsdesign best\u00e4tigen?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000031 elementor-widget elementor-widget-text-editor\" data-id=\"nr000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Inbetriebnahmeprotokolle sollten das tats\u00e4chliche Systemverhalten mit dem genehmigten Design vergleichen. Ein qualifizierter K\u00e4lteanlagenbauer oder Ingenieur kann die Betriebsbedingungen und die f\u00fcr die ausgew\u00e4hlten Ger\u00e4te relevanten Punkte \u00fcberpr\u00fcfen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000032 elementor-widget elementor-widget-text-editor\" data-id=\"nr000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Erfassen Sie K\u00e4ltemittel, Umgebungsbedingungen, Lastzustand, Verdichterstufe oder -drehzahl, Saug- und Druckgasbedingungen, den Zustand der Fl\u00fcssigkeitsleitung sowie die Messorte. Vergleichen Sie den Druckverlust und die Betriebstemperaturen mit den Grenzen des Herstellers. Schlie\u00dfen Sie bei Systemen mit variabler Leistung den niedrigsten Betriebspunkt ein, den der Inbetriebnahmeplan sicher testen kann.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000033 elementor-widget elementor-widget-image\" data-id=\"nr000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning.webp\" class=\"attachment-full size-full wp-image-7145\" alt=\"Techniker beim Messen von K\u00e4ltemitteldruck und Leitungstemperatur an einer Kompressor-Servicestelle.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Generiertes Konzeptbild, kein echter Test oder Domi-Wartungsnachweis.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000034 elementor-widget elementor-widget-text-editor\" data-id=\"nr000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Symptome wie niedriger Saugdruck, schlechter \u00d6lstand, Flash-Gas, Vibrationen oder ungleichm\u00e4\u00dfige Spulenleistung k\u00f6nnen verschiedene Ursachen haben. Sie beweisen nicht, dass eine Rohrleitung unterdimensioniert ist. \u00dcberpr\u00fcfen Sie Instrumente, K\u00e4ltemittelbef\u00fcllung, Steuerungen, Drosselstellen, Luftstrom und Anlagenzustand, bevor Sie das Leitungsdesign \u00e4ndern. Handhabung des K\u00e4ltemittels, Hartl\u00f6ten, Druckpr\u00fcfung und R\u00fcckgewinnung sollten von qualifiziertem Personal unter Einhaltung der geltenden Sicherheitsvorfahren durchgef\u00fchrt werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000035 elementor-widget elementor-widget-heading\" data-id=\"nr000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-an-oem-include-in-a-refrigerant-piping-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was sollte ein OEM in einer Anfrage f\u00fcr K\u00e4ltemittelrohrleitungen (RFQ) angeben?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000036 elementor-widget elementor-widget-text-editor\" data-id=\"nr000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr eine n\u00fctzliche Rohrleitungspr\u00fcfung senden Sie die Systemgrenze und den Betriebszustand. F\u00fcgen Sie der Zeichnung eine Einzelleitungsliste bei; eine Kompressoranschlussgr\u00f6\u00dfe allein beschreibt nicht den Verlauf.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000037 elementor-widget elementor-widget-text-editor\" data-id=\"nr000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Anwendung: Ger\u00e4tetyp, Temperaturbereich, Aufstellungsort im Innen- oder Au\u00dfenbereich und Einschaltdauer.<\/li>\n<li>K\u00e4ltemittel: exaktes K\u00e4ltemittel, \u00d6l und zugelassene Alternativen.<\/li>\n<li>Leistung und Bedingungen: Auslegungsleistung, Verdampfungs- und Verfl\u00fcssigungsbedingungen, Umgebungstemperaturbereich sowie Mindest- und H\u00f6chstlast.<\/li>\n<li>Ausr\u00fcstung: Kompressor, Verfl\u00fcssiger, Verdampfer, Expansionseinrichtung und Anschlussdaten.<\/li>\n<li>Verlauf: Teilstreckenl\u00e4ngen, H\u00f6henunterschiede, Formst\u00fccke, Abzweige und Installationsbegrenzungen.<\/li>\n<li>Materialien: Rohrnorm, Material, Verbindungsmethode, Auslegungsdruck, Isolierung und Ausf\u00fchrung.<\/li>\n<li>Betriebsmodi: Teillast, Stufenschaltung, Drehzahlregelung, Abtauung, Abpumpen oder W\u00e4rmepumpenumkehr.<\/li>\n<li>Dokumente: Rohrleitungsschema, Ger\u00e4telisten, Auslegungsreferenz und Zeichnungsrevision.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000038 elementor-widget elementor-widget-image\" data-id=\"nr000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing.webp\" class=\"attachment-full size-full wp-image-7146\" alt=\"Rohrleitungsschema, Ger\u00e4teschema und Fitting-Muster, zusammengestellt f\u00fcr eine OEM-Designpr\u00fcfung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Konzeptpaket. Es enth\u00e4lt keine echten Kunden- oder Projektdaten.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000039 elementor-widget elementor-widget-text-editor\" data-id=\"nr000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn das System einen kundenspezifischen W\u00e4rmetauscher oder ein Verfl\u00fcssigungssatz-Paket enth\u00e4lt, nehmen Sie die Rohrleitungsschnittstelle in denselben Zeichnungssatz wie die Verdampferleistung, das K\u00e4ltemittel, die Anschl\u00fcsse und den Installationsraum auf. Die Ingenieurseite von Domi beschreibt die Unterst\u00fctzung f\u00fcr W\u00e4rme\u00fcbertragungsanforderungen und die Zeichnungspr\u00fcfung bei W\u00e4rmetauscherprojekten. Best\u00e4tigen Sie den angeforderten Engineering-Umfang mit dem Team, bevor Sie sich darauf f\u00fcr die komplette Systemrohrleitungsauslegung verlassen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003a elementor-widget elementor-widget-heading\" data-id=\"nr00003a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufig gestellte Fragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003b elementor-widget elementor-widget-heading\" data-id=\"nr00003b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-different-types-of-refrigerant-pipes\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was sind die verschiedenen Arten von K\u00e4ltemittelrohren?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003c elementor-widget elementor-widget-text-editor\" data-id=\"nr00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die drei g\u00e4ngigen Hauptleitungsfunktionen sind Saugleitung, Druckleitung und Fl\u00fcssigkeitsleitung. Ein gr\u00f6\u00dferes System kann auch Abzweige, Sammler, Hei\u00dfgasabtau-, Economizer- oder reversible W\u00e4rmepumpenleitungen umfassen. Das Schema und der K\u00e4ltemittelzustand bestimmen die korrekte Bezeichnung und Auslegungspr\u00fcfung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003d elementor-widget elementor-widget-heading\" data-id=\"nr00003d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-material-is-used-for-refrigerant-piping\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Welches Material wird f\u00fcr K\u00e4ltemittelrohre verwendet?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003e elementor-widget elementor-widget-text-editor\" data-id=\"nr00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kupfer-ACR-Rohre gem\u00e4\u00df ASTM B280 sind im K\u00e4lteanlagenbau \u00fcblich. Material- und Wandst\u00e4rkenspezifikationen h\u00e4ngen weiterhin von K\u00e4ltemittel, Auslegungsdruck, Temperatur, Armaturen, Ger\u00e4tezulassung und Vorschriften ab. Verwenden Sie keine allgemeine Materialbezeichnung als Ersatz f\u00fcr die Systemspezifikation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003f elementor-widget elementor-widget-heading\" data-id=\"nr00003f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-size-refrigerant-lines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wie dimensionieren Sie K\u00e4ltemittelleitungen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000040 elementor-widget elementor-widget-text-editor\" data-id=\"nr000040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwenden Sie die Tabelle oder das Auslegungstool des Herstellers der ausgew\u00e4hlten Ausr\u00fcstung mit K\u00e4ltemittel, Leistung, Verdampfungs- und Verfl\u00fcssigungsbedingungen, Leitungsl\u00e4nge, H\u00f6he, Armaturen und dem vollen Leistungsbereich. \u00dcberpr\u00fcfen Sie die \u00d6lr\u00fcckf\u00fchrung in der Saugleitung bei Mindestlast und den Druckabfall an den erforderlichen Betriebspunkten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000041 elementor-widget elementor-widget-heading\" data-id=\"nr000041\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"are-refrigerant-line-sizes-standard\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sind die K\u00e4ltemittelleitungsgr\u00f6\u00dfen genormt?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000042 elementor-widget elementor-widget-text-editor\" data-id=\"nr000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Rohrleitungen sind in Standardgr\u00f6\u00dfen erh\u00e4ltlich, aber eine Standardgr\u00f6\u00dfenliste identifiziert nicht die korrekte Gr\u00f6\u00dfe f\u00fcr ein System. Verwenden Sie K\u00e4ltemittel, Betriebsbedingungen, Leitungsweg, Leistung, Druckgrenze und Herstelleranweisungen zur Auswahl des Rohrs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000043 elementor-widget elementor-widget-heading\" data-id=\"nr000043\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-use-the-same-size-as-the-compressor-connection\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kann ich dieselbe Gr\u00f6\u00dfe wie den Kompressoranschluss verwenden?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000044 elementor-widget elementor-widget-text-editor\" data-id=\"nr000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nicht automatisch. Der Kompressoranschluss ist ein Anschlussma\u00df. Die Verbindungsleitung muss f\u00fcr den gesamten Kreislauf und Betriebsbereich ausgew\u00e4hlt werden. \u00dcberpr\u00fcfen Sie die freigegebenen Ger\u00e4tedaten und die Leitungsberechnung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000045 elementor-widget elementor-widget-heading\" data-id=\"nr000045\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-a-larger-suction-line-always-improve-performance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Verbessert eine gr\u00f6\u00dfere Sauggasleitung immer die Leistung?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000046 elementor-widget elementor-widget-text-editor\" data-id=\"nr000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Ein gr\u00f6\u00dferer Durchmesser kann die Reibung bei h\u00f6herem Durchfluss verringern, aber er kann auch die Gasgeschwindigkeit reduzieren, wenn das System mit geringer Leistung betrieben wird. Die Auswahl muss Druckverlust und \u00d6lr\u00fcckf\u00fchrung \u00fcber den gesamten tats\u00e4chlichen Lastbereich ausgleichen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000047 elementor-widget elementor-widget-heading\" data-id=\"nr000047\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-co2-use-the-same-refrigerant-piping-as-an-hfc-system\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Verwendet CO2 dieselben K\u00e4ltemittelrohrleitungen wie ein HFC-System?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000048 elementor-widget elementor-widget-text-editor\" data-id=\"nr000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Gehen Sie nicht einfach davon aus. CO2-Systeme haben andere Druckanforderungen und erfordern m\u00f6glicherweise andere Rohre, Fittings, Ventile und Sicherheitskomponenten. Befolgen Sie das freigegebene CO2-Systemdesign und die Ger\u00e4tedaten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000049 elementor-widget elementor-widget-heading\" data-id=\"nr000049\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-i-send-for-a-refrigerant-piping-review\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was sollte ich f\u00fcr eine \u00dcberpr\u00fcfung der K\u00e4ltemittelrohrleitung einreichen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004a elementor-widget elementor-widget-text-editor\" data-id=\"nr00004a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Senden Sie das Rohrleitungsschema, K\u00e4ltemittel, Leistung und Betriebsbedingungen, Komponentenmodelle, Leitungsl\u00e4ngen und -h\u00f6henunterschiede, Fitting-Layout, Materialspezifikation und Betriebsmodi. F\u00fcgen Sie die Planrevision bei und geben Sie an, welche Werte bereits best\u00e4tigt sind und welche noch \u00fcberpr\u00fcft werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004b elementor-widget elementor-widget-heading\" data-id=\"nr00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"review-the-coil-and-piping-interface-before-release\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00dcberpr\u00fcfen Sie die Schnittstelle zwischen Verdampfer\/Kondensator und Rohrleitung vor der Freigabe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004c elementor-widget elementor-widget-text-editor\" data-id=\"nr00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn Ihr Projekt einen kundenspezifischen Verdampfer, Kondensator oder eine Verfl\u00fcssigungssatz-Baugruppe umfasst, senden Sie die Zeichnung, das K\u00e4ltemittel, das Leistungsziel, die Betriebsbedingungen und den Rohrleitungsanschlussplan zusammen mit der Preisanfrage (RFQ). Domis Team beschreibt die Zeichnungspr\u00fcfung und die Unterst\u00fctzung durch die thermische Ingenieurtechnik f\u00fcr W\u00e4rmetauscherprojekte. Bitten Sie das Team zu best\u00e4tigen, ob die angeforderte Rohrleitungspr\u00fcfung in den Projektumfang f\u00e4llt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004d elementor-widget elementor-widget-text-editor\" data-id=\"nr00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/technische-fahigkeiten\/\">\u00dcberpr\u00fcfen Sie Domis Ingenieurskapazit\u00e4ten<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004e elementor-align-left elementor-widget elementor-widget-button\" data-id=\"nr00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/de\/kontakt\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Senden Sie eine Projektanfrage<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004f elementor-widget elementor-widget-heading\" data-id=\"nr00004f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-articles\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verwandte Artikel<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005f e-con-full e-flex e-con e-parent\" data-id=\"nr00005f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000054 e-con-full e-flex e-con e-parent\" data-id=\"nr000054\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000051 e-con-full e-flex e-con e-parent\" data-id=\"nr000051\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000050 elementor-widget elementor-widget-text-editor\" data-id=\"nr000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/leitfaden-zur-auswahl-von-kalteanlagen\/\">Leitfaden zur Auswahl von K\u00e4lteeinheiten f\u00fcr gewerbliche und OEM-Systeme<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000053 e-con-full e-flex e-con e-parent\" data-id=\"nr000053\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000052 elementor-widget elementor-widget-text-editor\" data-id=\"nr000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/kaltemittelverdichter\/\">K\u00e4lteverdichter: Typen, Dimensionierung und OEM-Auswahlleitfaden<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000059 e-con-full e-flex e-con e-parent\" data-id=\"nr000059\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000056 e-con-full e-flex e-con e-parent\" data-id=\"nr000056\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000055 elementor-widget elementor-widget-text-editor\" data-id=\"nr000055\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/kaltesteuerungen-leitfaden\/\">Leitfaden f\u00fcr K\u00e4lteregelung: Typen, Funktionen und RFQ-Eingaben<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000058 e-con-full e-flex e-con e-parent\" data-id=\"nr000058\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000057 elementor-widget elementor-widget-text-editor\" data-id=\"nr000057\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/kaltekreislauf\/\">K\u00e4ltemittelkreislauf erkl\u00e4rt: Die 4 Phasen und die Rolle der Register<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005e e-con-full e-flex e-con e-parent\" data-id=\"nr00005e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr00005b e-con-full e-flex e-con e-parent\" data-id=\"nr00005b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00005a elementor-widget elementor-widget-text-editor\" data-id=\"nr00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/heat-pump-system-guide\/\">Leitfaden f\u00fcr W\u00e4rmepumpensysteme f\u00fcr OEM-K\u00e4ufer<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005d e-con-full e-flex e-con e-parent\" data-id=\"nr00005d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00005c elementor-widget elementor-widget-text-editor\" data-id=\"nr00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/de\/produkt\/industrie-kaltekompressoren-verbundanlage-fur-kuhlhauser\/\">Industrielles K\u00e4ltekompressor-Rack f\u00fcr K\u00fchlh\u00e4user<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie mehr \u00fcber Eingangsparameter f\u00fcr die K\u00e4ltemittelleitungsdimensionierung, Pr\u00fcfungen der Sauggas-\u00d6lr\u00fcckf\u00fchrung, Druckverlustgrenzen, die Verlegung und dar\u00fcber, was OEM-K\u00e4ufer in eine Rohrleitungs-RFQ aufnehmen sollten.<\/p>","protected":false},"author":1,"featured_media":7135,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7147","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/comments?post=7147"}],"version-history":[{"count":3,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7147\/revisions"}],"predecessor-version":[{"id":7150,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7147\/revisions\/7150"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media\/7135"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media?parent=7147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/categories?post=7147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/tags?post=7147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}