{"id":7181,"date":"2026-10-08T18:07:49","date_gmt":"2026-10-08T10:07:49","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7181"},"modified":"2026-10-08T18:29:40","modified_gmt":"2026-10-08T10:29:40","slug":"refrigerant-types-guide","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/","title":{"rendered":"K\u00e4ltemittelarten: \u00fcber 100 Bezeichnungen, Gruppen und Anwendungen"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7181\" class=\"elementor elementor-7181\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000057 e-con-full e-flex e-con e-parent\" data-id=\"rt000057\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000002 e-con-full e-flex e-con e-parent\" data-id=\"rt000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000001 elementor-widget elementor-widget-text-editor\" data-id=\"rt000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>K\u00e4ltemittel werden \u00fcblicherweise auf drei Arten gruppiert: nach chemischer Stoffgruppe, danach, ob es sich um einen Reinstoff oder ein Gemisch handelt, und nach ihrer Sicherheitsklassifizierung. Diese Angaben beantworten unterschiedliche Fragen. F\u00fcr sich genommen belegen sie weder, dass ein K\u00e4ltemittel f\u00fcr ein bestimmtes System geeignet oder verf\u00fcgbar ist, noch dass es dort rechtlich eingesetzt werden darf. Dieser Leitfaden erl\u00e4utert die Kategorien, erfasst mehr als 100 K\u00e4ltemittelbezeichnungen aus dem ver\u00f6ffentlichten Geltungsbereich von AHRI 700 und zeigt, was K\u00e4ufer gewerblicher K\u00e4lteanlagen vor der Spezifikation von Registern oder Ger\u00e4ten pr\u00fcfen sollten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000003 elementor-widget elementor-widget-text-editor\" data-id=\"rt000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Zu einem Abschnitt springen:<\/strong> <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#refrigerant-categories-answer-different-questions\">K\u00e4ltemittelkategorien<\/a> \u00b7 <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#main-chemical-families-of-refrigerants\">Chemische Stoffgruppen<\/a> \u00b7 <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#100-refrigerant-designations-in-the-ahri-700-scope\">\u00dcber 100 Bezeichnungen<\/a> \u00b7 <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#which-refrigerants-are-used-in-commercial-refrigeration\">Gewerbliche Anwendungen<\/a> \u00b7 <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#compare-refrigerant-types-before-specifying-a-coil\">Registerkompatibilit\u00e4t<\/a> \u00b7 <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#what-to-include-in-a-refrigerant-or-coil-rfq\">Checkliste f\u00fcr Angebotsanfragen<\/a> \u00b7 <a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/#frequently-asked-questions\">H\u00e4ufige Fragen (FAQ)<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000004 elementor-widget elementor-widget-text-editor\" data-id=\"rt000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Alle Abbildungen in diesem Leitfaden wurden mit KI erstellt und veranschaulichen Konzepte. Es handelt sich weder um Domi-Produktbilder noch um Fabrikaufnahmen, Pr\u00fcfergebnisse oder freigegebene Ger\u00e4teauslegungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000005 elementor-widget elementor-widget-image\" data-id=\"rt000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups.webp\" class=\"attachment-full size-full wp-image-7170\" alt=\"Molecular models displayed in glass cases with refrigeration components in background.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-family-groups-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000006 elementor-widget elementor-widget-heading\" data-id=\"rt000006\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"refrigerant-categories-answer-different-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">K\u00e4ltemittelkategorien beantworten unterschiedliche Fragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000007 elementor-widget elementor-widget-text-editor\" data-id=\"rt000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beginnen Sie mit der Frage, die Sie beantworten m\u00f6chten. Eine chemische Stoffgruppe beschreibt, woraus ein K\u00e4ltemittel besteht. Eine K\u00e4ltemittelbezeichnung steht f\u00fcr einen bestimmten Stoff oder ein Gemisch. Eine Sicherheitsgruppe fasst eine festgelegte Gefahrenklassifizierung zusammen. Eine beh\u00f6rdliche Listung gilt f\u00fcr einen benannten Verwendungszweck und eine bestimmte Zust\u00e4ndigkeit. Werden diese Angaben gleichgesetzt, f\u00fchrt das h\u00e4ufig zu Spezifikationsfehlern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000008 elementor-widget elementor-widget-text-editor\" data-id=\"rt000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><strong>Chemische Stoffgruppe:<\/strong> CFC, HCFC, HFC, HFO, Kohlenwasserstoff oder anorganisches\/nat\u00fcrliches K\u00e4ltemittel.<\/li>\n<li><strong>Zusammensetzung:<\/strong> Reinstoff oder K\u00e4ltemittelgemisch.<\/li>\n<li><strong>Verhalten des Gemischs:<\/strong> Bezeichnung eines zeotropen oder azeotropen Gemischs.<\/li>\n<li><strong>Sicherheitskennzeichnung:<\/strong> eine Klassifizierung, die f\u00fcr ein bestimmtes K\u00e4ltemittel in der einschl\u00e4gigen Norm oder Liste angegeben ist.<\/li>\n<li><strong>Verwendungsstatus:<\/strong> das Produkt, der Systemtyp, der Markt und die Bedingungen, die von der zust\u00e4ndigen Beh\u00f6rde benannt werden.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000009 elementor-widget elementor-widget-text-editor\" data-id=\"rt000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Auf der ver\u00f6ffentlichten AHRI-700-Seite f\u00fchrt AHRI K\u00e4ltemittel nach Klassen auf und verweist auf die SI-Ausgabe 2024. Die folgende Liste ist ein Verzeichnis der Bezeichnungen innerhalb dieses ver\u00f6ffentlichten Geltungsbereichs. Sie ist weder ein vollst\u00e4ndiger weltweiter Katalog noch eine Liste zur aktuellen Marktverf\u00fcgbarkeit oder Zulassung und ersetzt weder die aktuelle Norm noch \u00f6rtliche Vorschriften. <a href=\"https:\/\/www.ahrinet.org\/search-standards\/ahri-700-si-specifications-refrigerants\" target=\"_blank\" rel=\"noopener\">AHRI\u2019s refrigerant scope and AHRI 700 downloads<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000a elementor-widget elementor-widget-image\" data-id=\"rt00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition.webp\" class=\"attachment-full size-full wp-image-7168\" alt=\"Industrial refrigeration system with copper pipes and compressors in a modern facility.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-legacy-transition-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000b elementor-widget elementor-widget-heading\" data-id=\"rt00000b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"main-chemical-families-of-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wichtige chemische Stoffgruppen von K\u00e4ltemitteln<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000c elementor-widget elementor-widget-heading\" data-id=\"rt00000c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cfc-and-hcfc-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">CFC- und HCFC-K\u00e4ltemittel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000d elementor-widget elementor-widget-text-editor\" data-id=\"rt00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Chlorfluorkohlenwasserstoffe (CFC) enthalten Chlor, Fluor und Kohlenstoff. Hydrochlorfluorkohlenwasserstoffe (HCFC) enthalten zus\u00e4tzlich Wasserstoff. Nach Angaben der EPA k\u00f6nnen diese Stoffgruppen zum Abbau des stratosph\u00e4rischen Ozons beitragen; das Ozonabbaupotenzial von HCFC ist im Allgemeinen geringer als das von CFC. Viele bekannte Bezeichnungen dieser Gruppen stehen mit \u00e4lteren Ger\u00e4ten sowie Ausstiegs- oder Nutzungsbeschr\u00e4nkungen in Verbindung. Pr\u00fcfen Sie die Regelung f\u00fcr das betreffende Ger\u00e4t und den relevanten Zeitpunkt, statt ein altes Servicehandbuch als aktuelle Einsatzfreigabe zu behandeln. <a href=\"https:\/\/www.epa.gov\/snap\/questions-and-answers-about-snap\" target=\"_blank\" rel=\"noopener\">EPA\u2019s SNAP refrigerant Q&amp;A<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000e elementor-widget elementor-widget-heading\" data-id=\"rt00000e\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"hfc-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">HFC-K\u00e4ltemittel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000f elementor-widget elementor-widget-text-editor\" data-id=\"rt00000f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fluorkohlenwasserstoffe (HFC) enthalten Wasserstoff, Fluor und Kohlenstoff. Laut EPA bauen HFC die Ozonschicht nicht in erheblichem Umfang ab, viele weisen jedoch ein hohes Treibhauspotenzial auf. R-134a und R-404A sind bekannte Beispiele f\u00fcr HFC-K\u00e4ltemittel oder K\u00e4ltemittel mit HFC-Anteil. Die Angabe der chemischen Stoffgruppe sagt nichts \u00fcber die ma\u00dfgebliche GWP-Berechnung, den Verwendungsstatus oder die Systemkompatibilit\u00e4t aus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000010 elementor-widget elementor-widget-heading\" data-id=\"rt000010\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"hfo-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">HFO-K\u00e4ltemittel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000011 elementor-widget elementor-widget-text-editor\" data-id=\"rt000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hydrofluorolefine (HFO) sind unges\u00e4ttigte fluorierte Verbindungen. HFO und HFO-haltige Gemische werden bei neueren Ger\u00e4ten und Nachr\u00fcstungen diskutiert. Leistung, Sicherheitsklassifizierung und Verwendungsbedingungen m\u00fcssen weiterhin f\u00fcr das jeweilige Produkt und den konkreten Einsatz gepr\u00fcft werden. Gehen Sie nicht davon aus, dass alle HFO-Gemische dieselben Eigenschaften oder denselben Status haben.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000012 elementor-widget elementor-widget-heading\" data-id=\"rt000012\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"hydrocarbon-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kohlenwasserstoff-K\u00e4ltemittel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000013 elementor-widget elementor-widget-text-editor\" data-id=\"rt000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zu den Kohlenwasserstoff-K\u00e4ltemitteln z\u00e4hlen beispielsweise Propan (R-290), Isobutan (R-600a) und Butan (R-600). Aus den Tabellen der EPA zu Verwendungszwecken geht hervor, dass ein Kohlenwasserstoff f\u00fcr bestimmte Ger\u00e4tetypen unter festgelegten Einsatzbedingungen gelistet sein kann. Die Brennbarkeit wirkt sich auf F\u00fcllmengenbegrenzungen, Systemaufbau, Installation, Serviceverfahren und die geltende Produktnorm aus. Der K\u00e4ltemittelname allein belegt nicht, dass eine Auslegung sicher ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000014 elementor-widget elementor-widget-heading\" data-id=\"rt000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"natural-and-inorganic-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Nat\u00fcrliche und anorganische K\u00e4ltemittel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000015 elementor-widget elementor-widget-text-editor\" data-id=\"rt000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In der K\u00e4ltetechnik z\u00e4hlen zu den nat\u00fcrlichen K\u00e4ltemitteln h\u00e4ufig Kohlenstoffdioxid (R-744), Ammoniak (R-717) und Kohlenwasserstoffe wie R-290. Diese Stoffe unterscheiden sich hinsichtlich Druck, Toxizit\u00e4t, Brennbarkeit, Effizienz und Anforderungen an die Ger\u00e4teauslegung. \u201eNat\u00fcrlich\u201c beschreibt die Herkunft und ist weder eine Sicherheitsbewertung noch eine allgemeine Auslegungsempfehlung. Die SNAP-Tabellen der EPA enthalten f\u00fcr einzelne Alternativen produktspezifische Klassifizierungen und Bedingungen f\u00fcr den jeweiligen Verwendungszweck. <a href=\"https:\/\/www.epa.gov\/snap\/substitutes-industrial-process-refrigeration\" target=\"_blank\" rel=\"noopener\">Von der EPA gelistete Ersatzstoffe f\u00fcr industrielle Prozessk\u00e4lte<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000016 elementor-widget elementor-widget-image\" data-id=\"rt000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack.webp\" class=\"attachment-full size-full wp-image-7172\" alt=\"Industrial refrigeration system with pipes, compressors, and cooling units at Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-co2-rack-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000017 elementor-widget elementor-widget-heading\" data-id=\"rt000017\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"single-component-refrigerants-and-blends\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Reinstoffe und K\u00e4ltemittelgemische<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000018 elementor-widget elementor-widget-text-editor\" data-id=\"rt000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Reinstoff besteht aus einer chemischen Verbindung. Ein Gemisch kombiniert zwei oder mehr Komponenten in einer festgelegten Zusammensetzung und unter einer bestimmten Bezeichnung. Gemische k\u00f6nnen zeotrop oder azeotrop sein. Druck-Temperatur-Verhalten, Temperaturgleit, Bef\u00fcllungshinweise und Betriebsbereich h\u00e4ngen vom jeweiligen Gemisch und System ab. Ma\u00dfgeblich sind die Angaben des Ger\u00e4teherstellers und die technischen Unterlagen des K\u00e4ltemittellieferanten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000019 elementor-widget elementor-widget-text-editor\" data-id=\"rt000019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die folgenden Beispiele nennen ausschlie\u00dflich Bezeichnungen. Aus der Bezeichnung lassen sich weder ein sicherer Betriebsdruck noch ein GWP-Wert, eine F\u00fcllmengenbegrenzung, ein Zulassungsstatus oder eine Nachr\u00fcstanweisung ableiten. Verwenden Sie f\u00fcr technische Entscheidungen aktuelle Daten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001a elementor-widget elementor-widget-image\" data-id=\"rt00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior.webp\" class=\"attachment-full size-full wp-image-7171\" alt=\"Industrial refrigeration system with copper pipes and a transparent tube containing liquid.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-blend-behavior-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001b elementor-widget elementor-widget-heading\" data-id=\"rt00001b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"100-refrigerant-designations-in-the-ahri-700-scope\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00dcber 100 K\u00e4ltemittelbezeichnungen im Geltungsbereich von AHRI 700<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001c elementor-widget elementor-widget-text-editor\" data-id=\"rt00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dieses gruppierte Verzeichnis enth\u00e4lt mehr als 100 Bezeichnungen aus dem ver\u00f6ffentlichten K\u00e4ltemittelumfang von AHRI. Es soll K\u00e4ufern helfen, K\u00e4ltemittelnamen in Zeichnungen, Serviceunterlagen, Produktdaten und Angebotsanfragen zu erkennen. Eine hier aufgef\u00fchrte Bezeichnung bedeutet nicht, dass das K\u00e4ltemittel aktuell verkauft wird, f\u00fcr einen bestimmten Verwendungszweck zul\u00e4ssig oder f\u00fcr ein bestimmtes Ger\u00e4t geeignet ist. Die SNAP-Entscheidungen der EPA beziehen sich jeweils auf einen bestimmten Ersatzstoff und Verwendungszweck. <a href=\"https:\/\/www.epa.gov\/snap\/questions-and-answers-about-snap\" target=\"_blank\" rel=\"noopener\">So pr\u00fcfen Sie den SNAP-Status laut EPA<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001d elementor-widget elementor-widget-heading\" data-id=\"rt00001d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"single-component-fluorocarbon-designations\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bezeichnungen einkomponentiger fluorierter K\u00e4ltemittel<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001e elementor-widget elementor-widget-text-editor\" data-id=\"rt00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-11, R-12, R-13, R-22, R-23, R-32, R-113, R-114, R-115, R-116, R-123, R-124, R-125, R-134a, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245fa, R-1224yd(Z), R-1233zd(E), R-1234yf, R-1234ze(E), R-1336mzz(Z), R-1336mzz(E).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001f elementor-widget elementor-widget-heading\" data-id=\"rt00001f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"single-component-hydrocarbon-designations\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bezeichnungen einkomponentiger Kohlenwasserstoffe<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000020 elementor-widget elementor-widget-text-editor\" data-id=\"rt000020\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-50, R-170, R-E170, R-290, R-600, R-600a, R-601, R-601a, R-610, R-1150, R-1270.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000021 elementor-widget elementor-widget-heading\" data-id=\"rt000021\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"carbon-dioxide\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kohlenstoffdioxid<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000022 elementor-widget elementor-widget-text-editor\" data-id=\"rt000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-744.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000023 elementor-widget elementor-widget-heading\" data-id=\"rt000023\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"zeotropic-blend-designations\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bezeichnungen zeotroper Gemische<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000024 elementor-widget elementor-widget-text-editor\" data-id=\"rt000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-401A, R-401B, R-402A, R-402B, R-403A, R-403B, R-404A, R-405A, R-406A, R-407A, R-407B, R-407C, R-407D, R-407E, R-407F, R-407G, R-407H, R-407I, R-408A, R-409A, R-409B, R-410A, R-410B, R-411A, R-411B, R-412A, R-413A, R-414A, R-414B, R-415A, R-415B, R-416A, R-417A, R-417B, R-417C, R-418A, R-419A, R-419B, R-420A, R-421A, R-421B, R-422A, R-422B, R-422C, R-422D, R-422E, R-423A, R-424A, R-425A, R-426A, R-427A, R-428A, R-429A, R-430A, R-431A, R-434A, R-435A, R-437A, R-438A, R-439A, R-440A, R-442A, R-444A, R-444B, R-445A, R-446A, R-447A, R-447B, R-448A, R-449A, R-449B, R-449C, R-450A, R-451A, R-451B, R-452A, R-452B, R-452C, R-453A, R-454A, R-454B, R-454C, R-454D, R-455A, R-455B, R-455C, R-456A, R-457A, R-457B, R-457C, R-457D, R-459B, R-460A, R-460B, R-460C, R-461A, R-462A, R-463A, R-464A, R-465A, R-466A, R-467A, R-468A, R-468B, R-468C, R-469A, R-470A, R-470B, R-471A, R-472A, R-472B, R-473A, R-475A, R-476A, R-477A, R-477B, R-478A.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000025 elementor-widget elementor-widget-heading\" data-id=\"rt000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"zeotropic-hydrocarbon-blend-designations\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bezeichnungen zeotroper Kohlenwasserstoffgemische<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000026 elementor-widget elementor-widget-text-editor\" data-id=\"rt000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-432A, R-433A, R-433B, R-433C, R-436A, R-436B, R-441A, R-443A.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000027 elementor-widget elementor-widget-heading\" data-id=\"rt000027\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"azeotropic-blend-designations\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bezeichnungen azeotroper Gemische<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000028 elementor-widget elementor-widget-text-editor\" data-id=\"rt000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-500, R-502, R-503, R-507A, R-508A, R-508B, R-509A, R-510A, R-511A, R-512A, R-513A, R-513B, R-514A, R-515A, R-515B, R-516A.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000029 elementor-widget elementor-widget-image\" data-id=\"rt000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types.webp\" class=\"attachment-full size-full wp-image-7180\" alt=\"Lamellenrohr-, kompakte Lamellen- und Rohrb\u00fcndelw\u00e4rmetauscher im Vergleich.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-heat-exchanger-types-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002a elementor-widget elementor-widget-heading\" data-id=\"rt00002a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"which-refrigerants-are-used-in-commercial-refrigeration\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Welche K\u00e4ltemittel werden in der Gewerbek\u00e4lte verwendet?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002b elementor-widget elementor-widget-text-editor\" data-id=\"rt00002b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr gewerbliche K\u00e4lteanlagen gibt es nicht das eine passende K\u00e4ltemittel. Die Auswahl h\u00e4ngt von Ger\u00e4tekategorie, Leistung, Temperaturniveau, F\u00fcllmenge, Auslegungsdruck, Betriebsumgebung, \u00f6rtlichen Vorschriften und verf\u00fcgbarer Servicekompetenz ab. H\u00e4ufige Beispiele in gewerblichen und industriellen Anwendungen sind Kohlenstoffdioxid (R-744), Ammoniak (R-717), Propan (R-290) und ausgew\u00e4hlte HFC-\/HFO-Gemische. Die aktuellen EPA-Tabellen unterscheiden unter anderem zwischen Supermarktanlagen, industrieller Prozessk\u00e4lte, K\u00fchllagern, Transportk\u00e4lte und weiteren Verwendungszwecken. Eine Listung in einer Tabelle gilt nicht automatisch f\u00fcr eine andere Kategorie. <a href=\"https:\/\/www.epa.gov\/snap\/substitutes-refrigeration-and-air-conditioning\" target=\"_blank\" rel=\"noopener\">SNAP-Ersatzstoffe der EPA nach K\u00e4lteanwendung<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002c elementor-widget elementor-widget-heading\" data-id=\"rt00002c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"commercial-food-retail-and-self-contained-equipment\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Lebensmitteleinzelhandel und eigenst\u00e4ndige Gewerbek\u00e4lteanlagen<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002d elementor-widget elementor-widget-text-editor\" data-id=\"rt00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>K\u00fchlm\u00f6bel, Verfl\u00fcssigungss\u00e4tze, Eisbereiter und eigenst\u00e4ndige K\u00fchlger\u00e4te sind unterschiedliche Anwendungskategorien. F\u00fcllmenge, Ger\u00e4teauslegung, Sicherheitsmerkmale und zul\u00e4ssige K\u00e4ltemittel k\u00f6nnen sich unterscheiden. Pr\u00fcfen Sie den genauen Ger\u00e4tetyp und ob es sich um ein Neuger\u00e4t oder eine Nachr\u00fcstung handelt, bevor Sie K\u00e4ltemittel vergleichen. Die EPA f\u00fchrt Haushaltsk\u00fchl- und Gefrierger\u00e4te <a href=\"https:\/\/www.epa.gov\/snap\/substitutes-household-refrigerators-and-freezers\" target=\"_blank\" rel=\"noopener\">Tabelle der EPA zu Haushaltsk\u00fchl- und Gefrierger\u00e4ten<\/a> als Beispiel f\u00fcr eine eng umrissene, anwendungsspezifische Listung auf; sie ist keine allgemeine Zulassungstabelle f\u00fcr gewerbliche Ger\u00e4te.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002e elementor-widget elementor-widget-image\" data-id=\"rt00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case.webp\" class=\"attachment-full size-full wp-image-7175\" alt=\"Gewerbliche Supermarkt-K\u00fchltheke mit offen dargestelltem Verdampfer und Rohrleitungen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-supermarket-case-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002f elementor-widget elementor-widget-heading\" data-id=\"rt00002f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"industrial-process-refrigeration-and-cold-storage\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Industrielle Prozessk\u00e4lte und K\u00fchllager<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000030 elementor-widget elementor-widget-text-editor\" data-id=\"rt000030\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In industriellen Anlagen k\u00f6nnen K\u00e4ltemittel eingesetzt werden, die spezielle Ger\u00e4te, Sicherheitssteuerungen, geschultes Bedienpersonal und eine Notfallplanung erfordern. Ammoniak und Kohlenstoffdioxid werden in industriellen Anwendungen verwendet, ihre Auslegungsanforderungen sind jedoch nicht austauschbar. Pr\u00fcfen Sie gemeinsam mit dem zust\u00e4ndigen Ingenieur die Systemnorm, Ger\u00e4tedaten, Betriebsbedingungen und \u00f6rtlichen Vorschriften.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000031 elementor-widget elementor-widget-image\" data-id=\"rt000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system.webp\" class=\"attachment-full size-full wp-image-7173\" alt=\"Industrial refrigeration system with large green compressors and piping.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-industrial-system-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000032 elementor-widget elementor-widget-heading\" data-id=\"rt000032\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"compact-commercial-refrigerators\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kompakte gewerbliche K\u00fchlger\u00e4te<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000033 elementor-widget elementor-widget-text-editor\" data-id=\"rt000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr kleine, eigenst\u00e4ndige Ger\u00e4te gelten andere Anforderungen an K\u00e4ltemittelf\u00fcllmenge und Aufbau als f\u00fcr eine gro\u00dfe Verbundanlage. Die EPA f\u00fchrt R-290 und R-600a f\u00fcr bestimmte Kategorien von K\u00fchl- und Gefrierger\u00e4ten auf, jeweils innerhalb des Geltungsbereichs und unter den Bedingungen der aktuellen Liste. <a href=\"https:\/\/www.epa.gov\/snap\/substitutes-household-refrigerators-and-freezers\" target=\"_blank\" rel=\"noopener\">EPA-Listungen f\u00fcr Haushaltsk\u00fchl- und Gefrierger\u00e4te<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000034 elementor-widget elementor-widget-image\" data-id=\"rt000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator.webp\" class=\"attachment-full size-full wp-image-7174\" alt=\"Commercial refrigeration unit with visible cooling components and empty interior.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-compact-refrigerator-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000035 elementor-widget elementor-widget-heading\" data-id=\"rt000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"compare-refrigerant-types-before-specifying-a-coil\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">K\u00e4ltemittel vor der Registerauslegung vergleichen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000036 elementor-widget elementor-widget-text-editor\" data-id=\"rt000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr OEMs und Ger\u00e4teeink\u00e4ufer ist zun\u00e4chst die vollst\u00e4ndige Anwendung entscheidend. Ein Register l\u00e4sst sich nicht allein anhand des K\u00e4ltemittelnamens ausw\u00e4hlen. Teilen Sie dem Registerlieferanten die Auslegungsbedingungen mit und best\u00e4tigen Sie die K\u00e4ltemittelwahl mit dem Systemingenieur, bevor Sie eine Zeichnung freigeben.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000037 elementor-widget elementor-widget-text-editor\" data-id=\"rt000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><strong>Betriebspunkte:<\/strong> Verdampfungs- und Verfl\u00fcssigungstemperaturen, Umgebungstemperaturbereich, \u00dcberhitzung, Unterk\u00fchlung und angestrebte K\u00e4lteleistung.<\/li>\n<li><strong>Druck- und Temperaturgrenzen:<\/strong> Auslegungsdruck, Pr\u00fcfdruck, maximale Betriebstemperatur und Druck- bzw. Temperaturspitzen.<\/li>\n<li><strong>W\u00e4rmetauscher:<\/strong> Kreislaufaufteilung, Rohrdurchmesser, Lamellenabstand, Anstr\u00f6mfl\u00e4che, Werkstoff, Beschichtung, Anschlussposition und zul\u00e4ssiger Druckverlust.<\/li>\n<li><strong>Systemkomponenten:<\/strong> Verdichtermodell, \u00d6l, Expansionsorgan, Ventile, Filtertrockner, Dichtungen und freigegebene Komponentenkombinationen.<\/li>\n<li><strong>Verhalten des Gemischs:<\/strong> Zusammensetzung, Temperaturgleit, Bef\u00fcllverfahren und Bewertungsbedingungen f\u00fcr den Leistungsvergleich.<\/li>\n<li><strong>Sicherheit und Konformit\u00e4t:<\/strong> F\u00fcllmenge, Raumgr\u00f6\u00dfe, L\u00fcftung, Leckageerkennung, Ger\u00e4tezulassung, Kennzeichnung, Serviceverfahren und geltende Marktanforderungen.<\/li>\n<li><strong>Verf\u00fcgbarkeit:<\/strong> K\u00e4ltemittelverf\u00fcgbarkeit, Serviceunterst\u00fctzung, Lieferung in Flaschen oder als Gro\u00dfgebinde, Lieferzeit und \u00f6rtliche Handhabungsvorschriften.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000038 elementor-widget elementor-widget-image\" data-id=\"rt000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match.webp\" class=\"attachment-full size-full wp-image-7178\" alt=\"Commercial refrigeration components including compressor, copper pipes, and heat exchanger.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-component-match-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000039 elementor-widget elementor-widget-text-editor\" data-id=\"rt000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Laut EPA bewertet das SNAP-Programm die Umwelt- und Gesundheitsvertr\u00e4glichkeit f\u00fcr einen bestimmten Verwendungszweck. Es w\u00e4hlt weder das wirksamste K\u00e4ltemittel f\u00fcr das Ger\u00e4t des K\u00e4ufers aus noch validiert es eine Registerauslegung. Best\u00e4tigen Sie Leistung und Komponentenkombination mit dem Systemhersteller und dem zust\u00e4ndigen Ingenieur. <a href=\"https:\/\/www.epa.gov\/snap\/questions-and-answers-about-snap\" target=\"_blank\" rel=\"noopener\">EPA\u2019s SNAP Q&amp;A on substitute selection<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003a elementor-widget elementor-widget-image\" data-id=\"rt00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room.webp\" class=\"attachment-full size-full wp-image-7177\" alt=\"Industrial refrigeration system with control panel and piping in a commercial setting.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-sensor-room-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003b elementor-widget elementor-widget-image\" data-id=\"rt00003b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope.webp\" class=\"attachment-full size-full wp-image-7176\" alt=\"Industrielles K\u00fchlsystem mit Kupferrohren und K\u00fchlkomponenten.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-operating-envelope-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003c elementor-widget elementor-widget-heading\" data-id=\"rt00003c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-to-include-in-a-refrigerant-or-coil-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Angaben f\u00fcr eine K\u00e4ltemittel- oder Registeranfrage<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003d elementor-widget elementor-widget-text-editor\" data-id=\"rt00003d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00dcbermitteln Sie gen\u00fcgend Angaben, damit der Lieferant die Registerschnittstellen pr\u00fcfen und die passende Ausf\u00fchrung anbieten kann. Kennzeichnen Sie unbekannte Werte als noch zu kl\u00e4ren, statt sie zu sch\u00e4tzen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003e elementor-widget elementor-widget-text-editor\" data-id=\"rt00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>K\u00e4ltemittelbezeichnung und Angabe, ob es sich um einen Reinstoff oder ein Gemisch handelt<\/li>\n<li>Anwendung und Ger\u00e4tekategorie, Installationsland sowie Neuger\u00e4t oder Nachr\u00fcstung<\/li>\n<li>Erforderliche K\u00e4lteleistung und die zugrunde gelegten Bewertungsbedingungen<\/li>\n<li>Verdampfungs- und Verfl\u00fcssigungsbedingungen, Umgebungstemperaturbereich, Luft- oder Wasservolumenstrom und Zieltemperatur<\/li>\n<li>Registerabmessungen, Anzahl der Kreisl\u00e4ufe, Rohr- und Lamellenwerkstoffe, Anschlussdetails und Beschichtungsanforderungen<\/li>\n<li>Druck- und Temperatur-Auslegungsgrenzen, Pr\u00fcfanforderungen und geltende Normen<\/li>\n<li>Menge, Bedarf an Mustern oder Prototypen, Verpackung, Lieferort und gew\u00fcnschter Liefertermin<\/li>\n<li>Erforderliche Zeichnungen, Pr\u00fcfprotokolle, Dichtheitspr\u00fcfverfahren oder weitere Qualit\u00e4tsunterlagen<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003f elementor-widget elementor-widget-image\" data-id=\"rt00003f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing.webp\" class=\"attachment-full size-full wp-image-7179\" alt=\"Technical engineering drawings of refrigeration components and tools.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-types-guide-rfq-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000040 elementor-widget elementor-widget-text-editor\" data-id=\"rt000040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei kundenspezifischen W\u00e4rmetauscheranforderungen siehe <a href=\"https:\/\/domirefrigeration.com\/de\/individuelle-registerfertigung\/\">Domi\u2019s custom coil fabrication options<\/a> und <a href=\"https:\/\/domirefrigeration.com\/de\/technische-fahigkeiten\/\">technische F\u00e4higkeiten<\/a>. Geben Sie K\u00e4ltemittel und Betriebspunkte im Zeichnungspaket an, damit sich die Auslegung f\u00fcr das vorgesehene System pr\u00fcfen l\u00e4sst.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000041 elementor-widget elementor-widget-heading\" data-id=\"rt000041\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufig gestellte Fragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000042 elementor-widget elementor-widget-heading\" data-id=\"rt000042\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-main-types-of-refrigerants\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Welche Haupttypen von K\u00e4ltemitteln gibt es?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000043 elementor-widget elementor-widget-text-editor\" data-id=\"rt000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zu den g\u00e4ngigen Gruppen z\u00e4hlen CFC, HCFC, HFC, HFO, Kohlenwasserstoffe, anorganische K\u00e4ltemittel und Gemische. Die Gruppe beschreibt die Chemie oder Zusammensetzung. Sie sagt nicht aus, ob ein K\u00e4ltemittel f\u00fcr ein bestimmtes System geeignet oder f\u00fcr einen bestimmten Verwendungszweck zul\u00e4ssig ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000044 elementor-widget elementor-widget-heading\" data-id=\"rt000044\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-refrigerant-types-are-used-in-commercial-refrigeration\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Welche K\u00e4ltemittel werden in der Gewerbek\u00e4lte eingesetzt?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000045 elementor-widget elementor-widget-text-editor\" data-id=\"rt000045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beispiele sind Kohlenstoffdioxid R-744, Ammoniak R-717, Propan R-290 sowie anwendungsspezifische HFC- oder HFO-Gemische. Die passende Option h\u00e4ngt von Systemkategorie, Temperatur, Leistung, F\u00fcllmenge, Sicherheitsauslegung, Servicekapazit\u00e4t und den aktuell geltenden Vorschriften f\u00fcr den jeweiligen Verwendungszweck ab.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000046 elementor-widget elementor-widget-heading\" data-id=\"rt000046\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-many-refrigerant-types-are-there\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wie viele K\u00e4ltemittelbezeichnungen gibt es?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000047 elementor-widget elementor-widget-text-editor\" data-id=\"rt000047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr Reinstoffe und Gemische gibt es mehr als 100 K\u00e4ltemittelbezeichnungen. Das Verzeichnis dieses Leitfadens folgt den Bezeichnungen im ver\u00f6ffentlichten Geltungsbereich von AHRI 700. Es ist keine Liste aktuell verf\u00fcgbarer oder allgemein zugelassener K\u00e4ltemittel.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000048 elementor-widget elementor-widget-heading\" data-id=\"rt000048\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-is-the-difference-between-refrigerant-family-and-safety\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Worin unterscheiden sich chemische Stoffgruppe und Sicherheitsklasse eines K\u00e4ltemittels?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000049 elementor-widget elementor-widget-text-editor\" data-id=\"rt000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine chemische Stoffgruppe beschreibt die molekulare Zusammensetzung, zum Beispiel HFC oder Kohlenwasserstoff. Die Sicherheitsklassifizierung ist ein separates Merkmal, das nach einem bestimmten Klassifizierungssystem vergeben wird. Die zul\u00e4ssigen Verwendungsbedingungen sind eine weitere, eigenst\u00e4ndige Frage. Pr\u00fcfen Sie alle drei Angaben f\u00fcr das konkrete Produkt und den jeweiligen Markt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004a elementor-widget elementor-widget-heading\" data-id=\"rt00004a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-r-410a-a-single-refrigerant-or-a-blend\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ist R-410A ein Reinstoff oder ein Gemisch?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004b elementor-widget elementor-widget-text-editor\" data-id=\"rt00004b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>R-410A ist ein bezeichnetes K\u00e4ltemittelgemisch und keine einzelne chemische Verbindung. Aus der Bezeichnung l\u00e4sst sich nicht ableiten, dass ein f\u00fcr ein anderes K\u00e4ltemittel ausgelegtes System ohne technische Pr\u00fcfung mit R-410A bef\u00fcllt oder umger\u00fcstet werden kann.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004c elementor-widget elementor-widget-heading\" data-id=\"rt00004c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-r-744-the-same-as-carbon-dioxide-refrigeration\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ist R-744 dasselbe wie Kohlenstoffdioxid in der K\u00e4ltetechnik?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004d elementor-widget elementor-widget-text-editor\" data-id=\"rt00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ja. R-744 ist die K\u00e4ltemittelbezeichnung f\u00fcr Kohlenstoffdioxid. Ein f\u00fcr R-744 ausgelegtes System muss dennoch f\u00fcr Betriebsdr\u00fccke, Temperaturbereich, Komponenten und Anwendung konstruiert werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004e elementor-widget elementor-widget-heading\" data-id=\"rt00004e\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-appearing-in-a-refrigerant-list-mean-a-type-is-approved\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bedeutet die Aufnahme in eine K\u00e4ltemittelliste, dass der Stoff f\u00fcr mein Ger\u00e4t zugelassen ist?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004f elementor-widget elementor-widget-text-editor\" data-id=\"rt00004f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Eine Bezeichnung in einer Normen- oder Reinheitsumfangsliste ist keine pauschale Zulassung. Die SNAP-Entscheidungen der EPA gelten f\u00fcr bestimmte Ersatzstoffe und Verwendungszwecke und k\u00f6nnen zus\u00e4tzlichen Bedingungen unterliegen. Pr\u00fcfen Sie die aktuelle Regelung f\u00fcr die genaue Ger\u00e4tekategorie und Zust\u00e4ndigkeit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000050 elementor-widget elementor-widget-heading\" data-id=\"rt000050\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-an-oem-replace-one-refrigerant-with-another-without-chan\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kann ein OEM ein K\u00e4ltemittel ersetzen, ohne das Register zu \u00e4ndern?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000051 elementor-widget elementor-widget-text-editor\" data-id=\"rt000051\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Gehen Sie nicht davon aus. Ein Ersatz kann Betriebsdruck, Leistung, Massenstrom, W\u00e4rme\u00fcbertragung, Anforderungen an \u00d6l und Komponenten sowie Sicherheitsma\u00dfnahmen ver\u00e4ndern. Lassen Sie den Systemaufbau vom Ger\u00e4teentwickler bewerten und die Registerspezifikation vor einer \u00c4nderung freigeben.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000052 elementor-widget elementor-widget-heading\" data-id=\"rt000052\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-refrigeration-resources\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Weitere Informationen zur K\u00e4ltetechnik<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000053 elementor-widget elementor-widget-text-editor\" data-id=\"rt000053\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/naturliche-kaltemittel-gewerbliche-kuhlung\/\">Nat\u00fcrliche K\u00e4ltemittel f\u00fcr die gewerbliche K\u00e4ltetechnik<\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/r-454b-refrigerant-guide\/\">K\u00e4ltemittel R-454B: A2L-Sicherheit, R-410A-Vergleich und Registerauslegung<\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/planungsleitfaden-fur-kaltemittelleitungen\/\">Leitfaden zur Auslegung von K\u00e4ltemittelleitungen<\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/teile-des-kuhlsystems\/\">Teile eines K\u00e4ltesystems<\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/was-ist-ein-warmetauscher\/\">Bauarten von W\u00e4rmetauschern<\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/individuelle-registerfertigung\/\">Individuelle Spulenfertigung<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000054 elementor-widget elementor-widget-heading\" data-id=\"rt000054\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"discuss-a-custom-coil-requirement\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Anforderungen an ein kundenspezifisches Register besprechen<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000055 elementor-widget elementor-widget-text-editor\" data-id=\"rt000055\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Senden Sie mit Ihrer Anfrage K\u00e4ltemittel, Anwendung, Bewertungsbedingungen, Registerabmessungen, Anschl\u00fcsse, St\u00fcckzahl und gew\u00fcnschten Liefertermin. Das Domi-Team kann die Angaben f\u00fcr ein Angebot zu einem kundenspezifischen Register pr\u00fcfen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000056 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"rt000056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/de\/kontakt\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Fordern Sie ein individuelles Angebot an<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Erfahren Sie, wie sich K\u00e4ltemittel nach chemischer Stoffgruppe, Bezeichnung, Gemisch und Anwendungsbereich unterscheiden. Pr\u00fcfen Sie anschlie\u00dfend \u00fcber 100 gelistete K\u00e4ltemittelbezeichnungen und die Angaben, die OEM-K\u00e4ufer verifizieren sollten.<\/p>","protected":false},"author":1,"featured_media":7169,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7181","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7181","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/comments?post=7181"}],"version-history":[{"count":12,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7181\/revisions"}],"predecessor-version":[{"id":7193,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7181\/revisions\/7193"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media\/7169"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media?parent=7181"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/categories?post=7181"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/tags?post=7181"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}