{"id":7296,"date":"2026-10-17T23:32:42","date_gmt":"2026-10-17T15:32:42","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7296"},"modified":"2026-10-17T23:36:58","modified_gmt":"2026-10-17T15:36:58","slug":"uberhitzung-und-unterkuhlung","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/de\/superheat-and-subcooling\/","title":{"rendered":"Superheat und Subcooling: Berechnungen, Messungen und Coil-Diagnose"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7296\" class=\"elementor elementor-7296\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b9 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt0000a8 e-con-full e-flex e-con e-parent\" data-id=\"rt0000a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000002 e-con-full e-flex e-con e-parent\" data-id=\"rt000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000001 elementor-widget elementor-widget-text-editor\" data-id=\"rt000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die \u00dcberhitzung ist die gemessene Dampftemperatur abz\u00fcglich der S\u00e4ttigungstemperatur bei gleichem Druck. Die Unterk\u00fchlung ist die S\u00e4ttigungstemperatur abz\u00fcglich der gemessenen Fl\u00fcssigkeitstemperatur bei gleichem Druck. Bei K\u00e4ltemittelgemischen mit Temperaturgleit ist f\u00fcr die \u00dcberhitzung der Taupunktwert und f\u00fcr die Unterk\u00fchlung der Siedepunktwert zu verwenden. Vergleichen Sie beide Messwerte mit den Vorgaben des Ger\u00e4teherstellers, bevor Sie eine St\u00f6rung diagnostizieren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000003 elementor-widget elementor-widget-text-editor\" data-id=\"rt000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>OEM-Ingenieure und K\u00e4ltetechnik-Serviceteams m\u00fcssen entscheiden, welche Pr\u00fcfung als N\u00e4chstes durchgef\u00fchrt werden soll. Ein unerwarteter Messwert kann eine \u00dcberpr\u00fcfung des Messf\u00fchlers oder eine genauere Kontrolle der K\u00e4ltemittelversorgung erforderlich machen. Das Nachf\u00fcllen von K\u00e4ltemittel oder der Austausch des Verdampfers erfordern weitere Nachweise.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000004 elementor-widget elementor-widget-text-editor\" data-id=\"rt000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dieser Leitfaden behandelt konventionelle subkritische K\u00e4lte- und K\u00fchlsysteme mit Direktverdampfung. Die herk\u00f6mmlichen Berechnungen der Kondensator-Unterk\u00fchlung sind nicht auf einen transkritischen CO2-Gask\u00fchler anwendbar. Der Umgang mit K\u00e4ltemitteln und Serviceanschl\u00fcsse d\u00fcrfen nur von qualifiziertem Fachpersonal gem\u00e4\u00df den Verfahren des Ger\u00e4teherstellers durchgef\u00fchrt werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000005 elementor-widget elementor-widget-text-editor\" data-id=\"rt000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Springen zu: <a href=\"#how-do-you-calculate-superheat-and-subcooling\"><u>Berechnungen<\/u><\/a>, <a href=\"#where-should-pressure-and-temperature-be-measured\"><u>Messpunkte<\/u><\/a>, <a href=\"#dew-or-bubble-which-p-t-value-should-you-use\"><u>Taupunkt und Siedepunkt<\/u><\/a>, <a href=\"#what-do-high-and-low-readings-suggest\"><u>Diagnostische Kombinationen<\/u><\/a>, <a href=\"#worked-oem-example-check-the-probe-before-changing-the-coil\"><u>Durchgerechnetes OEM-Beispiel<\/u><\/a>, oder <a href=\"#build-a-coil-review-packet-from-the-measurements\"><u>Eingabedaten f\u00fcr die \u00dcberpr\u00fcfung des W\u00e4rmetauschers<\/u><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000006 elementor-widget elementor-widget-text-editor\" data-id=\"rt000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die originalen KI-generierten Illustrationen erl\u00e4utern die Konzepte. Sie sind weder Werksaufnahmen von Domi noch gemessene Pr\u00fcfergebnisse oder Installationszeichnungen. Die Zahlenbeispiele sind hypothetisch.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000a9 e-con-full e-flex e-con e-parent\" data-id=\"rt0000a9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000007 elementor-widget elementor-widget-heading\" data-id=\"rt000007\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-do-superheat-and-subcooling-measure\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was messen \u00dcberhitzung und Unterk\u00fchlung?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000008 elementor-widget elementor-widget-text-editor\" data-id=\"rt000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beide Gr\u00f6\u00dfen sind Temperaturdifferenzen, die sich auf den S\u00e4ttigungszustand eines K\u00e4ltemittels beziehen. Sie entsprechen weder der Rohrtemperatur selbst noch der Temperaturdifferenz der Luft \u00fcber einem W\u00e4rmetauscher.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000009 elementor-widget elementor-widget-text-editor\" data-id=\"rt000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die \u00dcberhitzung beschreibt den Temperaturbereich des Dampfes oberhalb der Sattdampfgrenze. Die Unterk\u00fchlung beschreibt den Temperaturbereich der Fl\u00fcssigkeit unterhalb der Siedelinie. Bei einem Einstoff-K\u00e4ltemittel gibt es f\u00fcr einen bestimmten Druck eine einzige S\u00e4ttigungstemperatur. Bei einem Gemisch mit Temperaturgleit muss der jeweils geeignete Dampf- oder Fl\u00fcssigkeitsreferenzwert verwendet werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000a elementor-widget elementor-widget-image\" data-id=\"rt00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states.webp\" class=\"attachment-full size-full wp-image-7284\" alt=\"Kupferrohre mit Dampf- und Fl\u00fcssigkeitszust\u00e4nden in einer K\u00e4lteanlage.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000020 e-con-full e-flex e-con e-parent\" data-id=\"rt000020\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000011 e-con-full elementor-hidden-mobile e-flex e-con e-parent\" data-id=\"rt000011\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00000c e-con-full e-flex e-con e-parent\" data-id=\"rt00000c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000b elementor-widget elementor-widget-text-editor\" data-id=\"rt00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Menge<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00000e e-con-full e-flex e-con e-parent\" data-id=\"rt00000e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000d elementor-widget elementor-widget-text-editor\" data-id=\"rt00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Zu bewertender K\u00e4ltemittelzustand<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000010 e-con-full e-flex e-con e-parent\" data-id=\"rt000010\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000f elementor-widget elementor-widget-text-editor\" data-id=\"rt00000f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Praktische Fragestellung<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000018 e-con-full e-flex e-con e-parent\" data-id=\"rt000018\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000013 e-con-full e-flex e-con e-parent\" data-id=\"rt000013\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000012 elementor-widget elementor-widget-text-editor\" data-id=\"rt000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gr\u00f6\u00dfe:<\/strong> \u00dcberhitzung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000015 e-con-full e-flex e-con e-parent\" data-id=\"rt000015\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000014 elementor-widget elementor-widget-text-editor\" data-id=\"rt000014\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Zu bewertender K\u00e4ltemittelzustand:<\/strong> Dampf im Verh\u00e4ltnis zum lokalen Sattdampfzustand<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000017 e-con-full e-flex e-con e-parent\" data-id=\"rt000017\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000016 elementor-widget elementor-widget-text-editor\" data-id=\"rt000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Praktische Fragestellung:<\/strong> Entspricht der gemessene Zustand am Verdampferaustritt den Anforderungen des Verdampfers und des Verdichters?<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001f e-con-full e-flex e-con e-parent\" data-id=\"rt00001f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00001a e-con-full e-flex e-con e-parent\" data-id=\"rt00001a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000019 elementor-widget elementor-widget-text-editor\" data-id=\"rt000019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gr\u00f6\u00dfe:<\/strong> Unterk\u00fchlung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001c e-con-full e-flex e-con e-parent\" data-id=\"rt00001c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001b elementor-widget elementor-widget-text-editor\" data-id=\"rt00001b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Zu bewertender K\u00e4ltemittelzustand:<\/strong> Fl\u00fcssigkeit im Verh\u00e4ltnis zur lokalen S\u00e4ttigungstemperatur der Fl\u00fcssigkeit<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001e e-con-full e-flex e-con e-parent\" data-id=\"rt00001e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001d elementor-widget elementor-widget-text-editor\" data-id=\"rt00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Praktische Fragestellung:<\/strong> Ist an der Stelle, an der es ben\u00f6tigt wird, ein ausreichender Fl\u00fcssigkeitsspielraum vorhanden?<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000021 elementor-widget elementor-widget-text-editor\" data-id=\"rt000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der <a href=\"https:\/\/domirefrigeration.com\/de\/kaltekreislauf\/\"><u>Leitfaden f\u00fcr den K\u00e4ltemittelkreislauf<\/u><\/a> erl\u00e4utert den gesamten Kreislauf. Hier liegt der Schwerpunkt auf dem Messprotokoll und den darauf basierenden Entscheidungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000aa e-con-full e-flex e-con e-parent\" data-id=\"rt0000aa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000022 elementor-widget elementor-widget-heading\" data-id=\"rt000022\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-calculate-superheat-and-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie berechnet man \u00dcberhitzung und Unterk\u00fchlung?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000023 elementor-widget elementor-widget-text-editor\" data-id=\"rt000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwenden Sie die K\u00e4ltemittelbezeichnung, den lokal gemessenen Druck und die korrekten Druck-Temperatur-Daten, um den S\u00e4ttigungsreferenzwert zu ermitteln. F\u00fchren Sie anschlie\u00dfend die Subtraktion in der richtigen Reihenfolge durch:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000024 elementor-widget elementor-widget-text-editor\" data-id=\"rt000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><strong>\u00dcberhitzung = gemessene Temperatur der Dampfleitung \u2212 Taupunkts\u00e4ttigungstemperatur.<\/strong><\/li>\n<li><strong>Unterk\u00fchlung = Blasenpunkts\u00e4ttigungstemperatur \u2212 gemessene Temperatur der Fl\u00fcssigkeitsleitung.<\/strong><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000025 elementor-widget elementor-widget-text-editor\" data-id=\"rt000025\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei einem reinen K\u00e4ltemittel verwenden Sie dessen einzigen S\u00e4ttigungswert. Das Copeland- <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEB&amp;PDF=95-14\" target=\"_blank\" rel=\"noopener\"><u>Informationsschreiben zum K\u00e4ltemittelwechsel 95-14<\/u><\/a> veranschaulicht die Berechnung anhand separater Dampf- und Fl\u00fcssigkeitsreferenzwerte f\u00fcr R-407C. Ersetzen Sie keines der beiden K\u00e4ltemitteltemperatur-Messwerte durch einen Lufttemperatur-Messwert.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000026 elementor-widget elementor-widget-heading\" data-id=\"rt000026\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"superheat-calculation-example\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beispiel f\u00fcr die Berechnung der \u00dcberhitzung<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000027 elementor-widget elementor-widget-text-editor\" data-id=\"rt000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Angenommen, die gemessene Rohrtemperatur am Verdampferausgang betr\u00e4gt 16 \u00b0C. Die korrekte P-T-Abfrage f\u00fcr denselben Messpunkt ergibt eine Taupunkttemperatur von 4 \u00b0C.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000028 elementor-widget elementor-widget-text-editor\" data-id=\"rt000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00dcberhitzung = 16 \u2212 4 = 12 K.<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000029 elementor-widget elementor-widget-image\" data-id=\"rt000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example.webp\" class=\"attachment-full size-full wp-image-7288\" alt=\"Industrierohr mit Temperaturmesswerten f\u00fcr Rohrtemperatur, Taupunkttemperatur und \u00dcberhitzung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002a elementor-widget elementor-widget-text-editor\" data-id=\"rt00002a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Ergebnis ist eine Temperaturdifferenz von 12 K. Es handelt sich weder um eine Rohrtemperatur von 12 \u00b0C noch um einen allgemeing\u00fcltigen Sollwert oder einen Nachweis f\u00fcr K\u00e4ltemittelmangel. Dieses Lehrbeispiel setzt kein tats\u00e4chliches Druck-Temperatur-Wertepaar voraus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002b elementor-widget elementor-widget-heading\" data-id=\"rt00002b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"subcooling-calculation-example\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beispiel f\u00fcr die Berechnung der Unterk\u00fchlung<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002c elementor-widget elementor-widget-text-editor\" data-id=\"rt00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Angenommen, die Temperatur der Fl\u00fcssigkeitsleitung betr\u00e4gt 35 \u00b0C. Die anhand des Drucks an genau diesem Messpunkt ermittelte Blasenpunkttemperatur betr\u00e4gt 43 \u00b0C.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002d elementor-widget elementor-widget-text-editor\" data-id=\"rt00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Unterk\u00fchlung = 43 \u2212 35 = 8 K.<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002e elementor-widget elementor-widget-image\" data-id=\"rt00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example.webp\" class=\"attachment-full size-full wp-image-7289\" alt=\"Temperaturdiagramm einer K\u00e4lteanlage mit Blasenpunkttemperatur bei 43 \u00b0C, Rohrtemperatur bei 35 \u00b0C und Unterk\u00fchlung von 8 K.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002f elementor-widget elementor-widget-text-editor\" data-id=\"rt00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine Temperaturdifferenz von 1 K entspricht einer Differenz von 1 \u00b0C oder 1,8 \u00b0F. Somit entsprechen 12 K einer \u00dcberhitzung von 21,6 \u00b0F und 8 K einer Unterk\u00fchlung von 14,4 \u00b0F. Bei der Umrechnung von Temperaturdifferenzen multiplizieren oder dividieren Sie mit 1,8; addieren oder subtrahieren Sie nicht 32.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ab e-con-full e-flex e-con e-parent\" data-id=\"rt0000ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000030 elementor-widget elementor-widget-heading\" data-id=\"rt000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"where-should-pressure-and-temperature-be-measured\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wo sollten Druck und Temperatur gemessen werden?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000031 elementor-widget elementor-widget-text-editor\" data-id=\"rt000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Druck und Temperatur m\u00fcssen dieselbe K\u00e4ltemittelstelle mit ausreichender Genauigkeit beschreiben, damit die vorgesehene Berechnung korrekt durchgef\u00fchrt werden kann. Ein leicht zug\u00e4nglicher Serviceanschluss kann ein schlechter Ersatz sein, wenn sich zwischen dem Anschluss und dem Temperaturf\u00fchler ein Regler, eine lange Rohrleitung oder ein erheblicher Druckabfall befindet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000032 elementor-widget elementor-widget-text-editor\" data-id=\"rt000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zur Bestimmung der \u00dcberhitzung am Verdampfer identifizieren Sie den Messpunkt am Ausgang in der N\u00e4he des F\u00fchlers oder den vom Reglerhersteller angegebenen Punkt. F\u00fcr die \u00dcberhitzung am Verdichtereintritt verwenden Sie die vom Verdichterhersteller festgelegte Saugdruck-Messstelle. Copelands <a href=\"https:\/\/copeland.custhelp.com\/app\/answers\/detail\/a_id\/955\/~\/operating-superheat%2C-subcooling-and-net-oil-pressure\" target=\"_blank\" rel=\"noopener\"><u>Richtlinien f\u00fcr Betriebsmessungen<\/u><\/a> unterscheiden ausdr\u00fccklich zwischen diesen beiden Messstellen und legen den Fl\u00fcssigkeitsmesspunkt in der N\u00e4he des Eingangs der Dosiereinrichtung fest, wenn dieser Betriebszustand \u00fcberpr\u00fcft wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000033 elementor-widget elementor-widget-image\" data-id=\"rt000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet.webp\" class=\"attachment-full size-full wp-image-7285\" alt=\"Nahaufnahme eines K\u00e4ltemittel-W\u00e4rmetauschers und eines isolierten Kupferrohrs in einer industriellen Umgebung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000034 elementor-widget elementor-widget-text-editor\" data-id=\"rt000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Kennzeichnen Sie das Ergebnis mit der jeweiligen Messstelle: \u201c\u00dcberhitzung am Verdampferaustritt\u201d oder \u201c\u00dcberhitzung am Verdichtereintritt\u201d. Ein Eintrag, der lediglich mit \u201cSH\u201d gekennzeichnet ist, l\u00e4sst den n\u00e4chsten Pr\u00fcfer im Unklaren dar\u00fcber, wo die Messung durchgef\u00fchrt wurde.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000035 elementor-widget elementor-widget-image\" data-id=\"rt000035\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet.webp\" class=\"attachment-full size-full wp-image-7286\" alt=\"K\u00e4ltesystem mit gekennzeichnetem Verdampferausgang und Kompressoreingang.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000036 elementor-widget elementor-widget-text-editor\" data-id=\"rt000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>W\u00e4rmeaufnahme und Druckverlust in der Saugleitung k\u00f6nnen den S\u00e4ttigungsabstand zwischen diesen Messpunkten ver\u00e4ndern. Ein h\u00f6herer Messwert am Verdichtereintritt bedeutet f\u00fcr sich genommen nicht, dass der Verdampfer unterversorgt ist. Wenn ein Druckregler die beiden Messstellen voneinander trennt, dokumentieren Sie, auf welcher Seite des Reglers der Druck gemessen wurde. Verwenden Sie die <a href=\"https:\/\/domirefrigeration.com\/de\/planungsleitfaden-fur-kaltemittelleitungen\/\"><u>Planungsleitfaden f\u00fcr K\u00e4ltemittelleitungen<\/u><\/a> f\u00fcr die separate Frage zur Leitungsdimensionierung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ac e-con-full e-flex e-con e-parent\" data-id=\"rt0000ac\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000037 elementor-widget elementor-widget-heading\" data-id=\"rt000037\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"dew-or-bubble-which-p-t-value-should-you-use\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Taupunkt oder Blasenpunkt: Welchen P-T-Wert sollten Sie verwenden?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000038 elementor-widget elementor-widget-text-editor\" data-id=\"rt000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwendung <strong>Taupunkt \/ ges\u00e4ttigter Dampf f\u00fcr die \u00dcberhitzung<\/strong> und <strong>Blasenpunkt \/ ges\u00e4ttigte Fl\u00fcssigkeit f\u00fcr die Unterk\u00fchlung<\/strong>. Eine mittlere Temperatur, die f\u00fcr die Leistungsbewertung einer K\u00fchlschlange verwendet wird, ist ein anderer Referenzwert. Sie sollte bei einer Serviceberechnung nicht stillschweigend an die Stelle des Taupunkt- oder Blasenpunktwerts treten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000039 elementor-widget elementor-widget-image\" data-id=\"rt000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble.webp\" class=\"attachment-full size-full wp-image-7287\" alt=\"K\u00e4ltemittelkennzeichnungen und Werkzeuge f\u00fcr die Wartung von K\u00e4lteanlagen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003a elementor-widget elementor-widget-text-editor\" data-id=\"rt00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nehmen wir beispielsweise an, ein hypothetisches K\u00e4ltemittelgemisch hat bei dem gemessenen Ausgangsdruck einen Blasenpunkt von 2 \u00b0C und einen Taupunkt von 6 \u00b0C. Wenn die Dampfleitung eine Temperatur von 10 \u00b0C aufweist, betr\u00e4gt die \u00dcberhitzung 10 \u2212 6 = 4 K. Bei Verwendung des Blasenpunkts erg\u00e4ben sich stattdessen 8 K, also ein Fehler von 4 K. Dieses Beispiel veranschaulicht die Auswahl des Referenzwerts und stellt keine P-T-Tabelle f\u00fcr ein bestimmtes K\u00e4ltemittel dar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003b elementor-widget elementor-widget-text-editor\" data-id=\"rt00003b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dokumentieren Sie das K\u00e4ltemittel und geben Sie an, ob es sich beim Druck um \u00dcberdruck oder Absolutdruck handelt. Eine korrekte Subtraktion mit einer falschen K\u00e4ltemitteleinstellung kann dennoch ein plausibel erscheinendes Ergebnis liefern. Bewahren Sie die Ger\u00e4tekonfiguration oder die verwendete P-T-Referenz zusammen mit dem Pr\u00fcfprotokoll auf, damit ein anderer Ingenieur das Ergebnis nachvollziehen kann.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ad e-con-full e-flex e-con e-parent\" data-id=\"rt0000ad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003c elementor-widget elementor-widget-heading\" data-id=\"rt00003c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-normal-superheat-and-subcooling-be\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Welche Werte sollten f\u00fcr die normale \u00dcberhitzung und Unterk\u00fchlung gelten?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003d elementor-widget elementor-widget-text-editor\" data-id=\"rt00003d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Sollwerte h\u00e4ngen von der Anlage und ihren Betriebsbedingungen ab, einschlie\u00dflich K\u00e4ltemittel, Dosiereinrichtung, Last, Messstelle und Verdichteranforderungen. Verwenden Sie die Betriebs- und Bef\u00fcllungsanweisungen des Herstellers f\u00fcr das genaue Modell und die jeweiligen Pr\u00fcfbedingungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003e elementor-widget elementor-widget-text-editor\" data-id=\"rt00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Regelungs-Sollwert f\u00fcr den Verdampfer und ein Schutzgrenzwert f\u00fcr den Verdichter beantworten unterschiedliche Fragen. Beispielsweise schreiben die Richtlinien von Copeland f\u00fcr die Verdichter <a href=\"https:\/\/copeland.custhelp.com\/app\/answers\/detail\/a_id\/2269\/~\/superheat-requirement-of-copeland-rft%2C-rrt%2C-rst-compressors\" target=\"_blank\" rel=\"noopener\"><u>RFT, RRT und RST<\/u><\/a> an der angegebenen Verdichtermessstelle eine Mindest\u00fcberhitzung von 20 \u00b0F bzw. etwa 11 K vor. Diese modellspezifische Anforderung ist kein Sollwert f\u00fcr jeden Verdampferaustritt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003f elementor-widget elementor-widget-text-editor\" data-id=\"rt00003f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Festdrosselorgan, ein TXV und ein EEV reagieren bei einer Last\u00e4nderung ebenfalls nicht identisch. Einige kompakte Klimager\u00e4te verwenden eine herstellerspezifische Bef\u00fcllungstabelle auf Grundlage der \u00dcberhitzung oder Unterk\u00fchlung; bei anderen Anlagen ist eine genau abgewogene K\u00e4ltemittelf\u00fcllmenge oder ein anderes Verfahren erforderlich. Ein allgemeiner Richtwert aus dem Internet kann die entsprechenden Herstellervorgaben nicht ersetzen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000040 elementor-widget elementor-widget-text-editor\" data-id=\"rt000040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn der urspr\u00fcngliche Sollwert fehlt, fordern Sie ihn an, bevor Sie die Stichprobe als akzeptabel einstufen. Die Beschaffung sollte einen an einem Prototyp beobachteten Wert nicht ohne Genehmigung durch die Entwicklungsabteilung in einen Produktionsgrenzwert umwandeln.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ae e-con-full e-flex e-con e-parent\" data-id=\"rt0000ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000041 elementor-widget elementor-widget-heading\" data-id=\"rt000041\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"check-the-measurement-before-diagnosing-a-component\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00dcberpr\u00fcfen Sie die Messung, bevor Sie eine Komponente diagnostizieren.<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000042 elementor-widget elementor-widget-text-editor\" data-id=\"rt000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Temperaturf\u00fchler ben\u00f6tigt einen ordnungsgem\u00e4\u00dfen Kontakt, eine geeignete Positionierung und die gem\u00e4\u00df seiner Anleitung erforderliche Isolierung. Vergleichen Sie seinen Messwert mit dem eines unabh\u00e4ngigen Messger\u00e4ts, wenn bereits eine geringe Abweichung die Diagnose ver\u00e4ndern w\u00fcrde. \u00dcberpr\u00fcfen Sie den Messbereich des Drucksensors und ob seine konfigurierte Referenz mit dem installierten Ger\u00e4t \u00fcbereinstimmt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000043 elementor-widget elementor-widget-image\" data-id=\"rt000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact.webp\" class=\"attachment-full size-full wp-image-7290\" alt=\"Vergleich zwischen gutem Kontakt und erneut zu \u00fcberpr\u00fcfendem Kontakt bei der Pr\u00fcfung von K\u00e4ltesensoren.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000044 elementor-widget elementor-widget-text-editor\" data-id=\"rt000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/419557\/BC457625021427en-000103.pdf\" target=\"_blank\" rel=\"noopener\"><u>Leitfaden f\u00fcr den Danfoss EKE 100-Regler<\/u><\/a> enth\u00e4lt Diagnoseeintr\u00e4ge f\u00fcr eine fehlende Temperaturf\u00fchlerkonfiguration, Signalfehler des Druckmessumformers und Verdrahtungsfehler des Saugleitungsf\u00fchlers. \u00dcberpr\u00fcfen Sie diese Eing\u00e4nge, bevor Sie ein Ventil austauschen oder die Spulengeometrie \u00e4ndern. Verwenden Sie den Leitfaden nur f\u00fcr die darin aufgef\u00fchrten Reglermodelle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000045 elementor-widget elementor-widget-text-editor\" data-id=\"rt000045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Betrachten wir ein hypothetisches Fehlerbudget. Wenn ein Rohrtemperaturmesswert um \u00b10,5 K und die aus dem Druck abgeleitete S\u00e4ttigungstemperatur um \u00b10,7 K fehlerhaft sein k\u00f6nnen, ergibt die konservative Addition dieser beiden Grenzwerte \u00b11,2 K. Dies ist keine formale Unsicherheitsberechnung, zeigt jedoch, warum eine Abweichung von 0,5 K gegen\u00fcber einem Sollwert nicht beurteilt werden kann, ohne die Messger\u00e4te zu \u00fcberpr\u00fcfen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000046 elementor-widget elementor-widget-text-editor\" data-id=\"rt000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn ein Ergebnis negativ oder nahe null ist, \u00fcberpr\u00fcfen Sie unverz\u00fcglich die Messung und den tats\u00e4chlichen Betriebszustand. Eine berechnete negative \u00dcberhitzung beschreibt keinen stabilen \u00fcberhitzten Dampf. Sie kann auf eine ungeeignete Referenz, eine fehlerhafte Messung oder einen Zustand hinweisen, der im Hinblick auf einen m\u00f6glichen Fl\u00fcssigkeitsr\u00fccklauf untersucht werden muss.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000af e-con-full e-flex e-con e-parent\" data-id=\"rt0000af\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000047 elementor-widget elementor-widget-heading\" data-id=\"rt000047\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-do-high-and-low-readings-suggest\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Worauf weisen hohe und niedrige Messwerte hin?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000048 elementor-widget elementor-widget-text-editor\" data-id=\"rt000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cHoch\u201d und \u201cniedrig\u201d beziehen sich auf den korrekten Sollwert der Anlage unter vergleichbaren Bedingungen. Die folgenden Messwertkombinationen dienen als Ans\u00e4tze f\u00fcr weitere Untersuchungen bei herk\u00f6mmlichen DX-Anlagen und sind keine universell g\u00fcltigen Fehlercodes. Systeme mit Fl\u00fcssigkeitssammler, Leistungsregelung, mehreren Kreisl\u00e4ufen und vor\u00fcbergehenden Betriebszust\u00e4nden k\u00f6nnen das Muster ver\u00e4ndern.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00006c e-con-full e-flex e-con e-parent\" data-id=\"rt00006c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00004f e-con-full elementor-hidden-mobile e-flex e-con e-parent\" data-id=\"rt00004f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00004a e-con-full e-flex e-con e-parent\" data-id=\"rt00004a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000049 elementor-widget elementor-widget-text-editor\" data-id=\"rt000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gekoppelte Beobachtung<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00004c e-con-full e-flex e-con e-parent\" data-id=\"rt00004c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004b elementor-widget elementor-widget-text-editor\" data-id=\"rt00004b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Sinnvolle n\u00e4chste \u00dcberpr\u00fcfung<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00004e e-con-full e-flex e-con e-parent\" data-id=\"rt00004e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004d elementor-widget elementor-widget-text-editor\" data-id=\"rt00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Noch ben\u00f6tigte Nachweise<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000056 e-con-full e-flex e-con e-parent\" data-id=\"rt000056\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000051 e-con-full e-flex e-con e-parent\" data-id=\"rt000051\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000050 elementor-widget elementor-widget-text-editor\" data-id=\"rt000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gekoppelte Beobachtung:<\/strong> Hohe \u00dcberhitzung, geringe Unterk\u00fchlung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000053 e-con-full e-flex e-con e-parent\" data-id=\"rt000053\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000052 elementor-widget elementor-widget-text-editor\" data-id=\"rt000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Sinnvolle n\u00e4chste \u00dcberpr\u00fcfung:<\/strong> Pr\u00fcfen Sie, ob das Expansionsorgan ausreichend mit Fl\u00fcssigkeit versorgt wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000055 e-con-full e-flex e-con e-parent\" data-id=\"rt000055\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000054 elementor-widget elementor-widget-text-editor\" data-id=\"rt000054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Noch ben\u00f6tigte Nachweise:<\/strong> Korrekte lokale Messwerte, \u00dcberpr\u00fcfung der K\u00e4ltemittelf\u00fcllmenge nach der zugelassenen Methode sowie Nachweise zu Leckagen oder zur Fl\u00fcssigkeitszufuhr.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00005d e-con-full e-flex e-con e-parent\" data-id=\"rt00005d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000058 e-con-full e-flex e-con e-parent\" data-id=\"rt000058\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000057 elementor-widget elementor-widget-text-editor\" data-id=\"rt000057\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gekoppelte Beobachtung:<\/strong> Hohe \u00dcberhitzung, hohe Unterk\u00fchlung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00005a e-con-full e-flex e-con e-parent\" data-id=\"rt00005a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000059 elementor-widget elementor-widget-text-editor\" data-id=\"rt000059\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Sinnvolle n\u00e4chste \u00dcberpr\u00fcfung:<\/strong> Untersuchen, ob der K\u00e4ltemittelstrom eingeschr\u00e4nkt oder unzureichend ist, obwohl fl\u00fcssiges K\u00e4ltemittel im vorgelagerten Bereich verf\u00fcgbar ist<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00005c e-con-full e-flex e-con e-parent\" data-id=\"rt00005c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005b elementor-widget elementor-widget-text-editor\" data-id=\"rt00005b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Noch ben\u00f6tigte Nachweise:<\/strong> Druckverluste, Zustand des Filtertrockners, Eignung des Ventils\/Verteilers und Messstellen<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000064 e-con-full e-flex e-con e-parent\" data-id=\"rt000064\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00005f e-con-full e-flex e-con e-parent\" data-id=\"rt00005f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005e elementor-widget elementor-widget-text-editor\" data-id=\"rt00005e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gekoppelte Beobachtung:<\/strong> Geringe \u00dcberhitzung, hohe Unterk\u00fchlung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000061 e-con-full e-flex e-con e-parent\" data-id=\"rt000061\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000060 elementor-widget elementor-widget-text-editor\" data-id=\"rt000060\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Sinnvolle n\u00e4chste \u00dcberpr\u00fcfung:<\/strong> Vor der Annahme einer \u00dcberf\u00fcllung die Last, den Luftstrom durch den Verdampfer und das Regelverhalten der Dosiereinrichtung \u00fcberpr\u00fcfen<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000063 e-con-full e-flex e-con e-parent\" data-id=\"rt000063\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000062 elementor-widget elementor-widget-text-editor\" data-id=\"rt000062\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Noch ben\u00f6tigte Nachweise:<\/strong> Stabiler Lastaufzeichnungswert, Ventilreaktion, Zustand am Verdichtereintritt und das Bef\u00fcllungsverfahren der Anlage<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00006b e-con-full e-flex e-con e-parent\" data-id=\"rt00006b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000066 e-con-full e-flex e-con e-parent\" data-id=\"rt000066\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000065 elementor-widget elementor-widget-text-editor\" data-id=\"rt000065\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gekoppelte Beobachtung:<\/strong> Geringe \u00dcberhitzung, geringe Unterk\u00fchlung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000068 e-con-full e-flex e-con e-parent\" data-id=\"rt000068\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000067 elementor-widget elementor-widget-text-editor\" data-id=\"rt000067\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Sinnvolle n\u00e4chste \u00dcberpr\u00fcfung:<\/strong> \u00dcberpr\u00fcfen Sie den Anlagenzustand und die G\u00fcltigkeit der Messungen, bevor Sie eine Ursache zuordnen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00006a e-con-full e-flex e-con e-parent\" data-id=\"rt00006a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000069 elementor-widget elementor-widget-text-editor\" data-id=\"rt000069\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Noch ben\u00f6tigte Nachweise:<\/strong> Anlauf-\/Abtaustatus, K\u00e4ltemittelreferenz, Last, Regelung und wiederholte Messwerte<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006d elementor-widget elementor-widget-text-editor\" data-id=\"rt00006d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine hohe \u00dcberhitzung bei gleichzeitig geringer Unterk\u00fchlung kann auf eine Unterf\u00fcllung hindeuten, doch diese Kombination allein reicht nicht aus, um dies zu best\u00e4tigen. Eine hohe \u00dcberhitzung bei gleichzeitig hoher Unterk\u00fchlung kann auf eine Drosselung in der K\u00e4ltemittelzufuhr hindeuten, allerdings nur, wenn die Unterk\u00fchlung an einer aussagekr\u00e4ftigen Stelle stromaufw\u00e4rts gemessen wurde und die Anlagenarchitektur diese Interpretation unterst\u00fctzt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006e elementor-widget elementor-widget-text-editor\" data-id=\"rt00006e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Copelands <a href=\"https:\/\/copeland.custhelp.com\/app\/answers\/detail\/a_id\/4108\/~\/bubbles-in-the-sight-glass\" target=\"_blank\" rel=\"noopener\"><u>Hinweise zum Schauglas<\/u><\/a> erkl\u00e4rt, warum Blasen durch Druckverluste entstehen k\u00f6nnen, wenn sich die Fl\u00fcssigkeit nahe dem S\u00e4ttigungszustand befindet, einschlie\u00dflich Druckverlusten an Drosselstellen. Es wird davor gewarnt, Blasen ausschlie\u00dflich mit einer zu geringen K\u00e4ltemittelf\u00fcllung gleichzusetzen. Blasen sind keine Aufforderung, K\u00e4ltemittel nachzuf\u00fcllen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006f elementor-widget elementor-widget-text-editor\" data-id=\"rt00006f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dokumentieren Sie die n\u00e4chste Pr\u00fcfung im Bericht. Bei einer m\u00f6glichen Einschr\u00e4nkung der K\u00e4ltemittelzufuhr geben Sie das vermutete Bauteil und die erforderlichen Druckmessungen auf beiden Seiten an. Der Techniker kann diese Erkl\u00e4rung anschlie\u00dfend \u00fcberpr\u00fcfen, bevor Teile ausgetauscht werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b0 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000070 elementor-widget elementor-widget-heading\" data-id=\"rt000070\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"why-can-condenser-subcooling-differ-from-valve-inlet-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum kann sich die Unterk\u00fchlung am Verfl\u00fcssiger von der Unterk\u00fchlung am Ventileintritt unterscheiden?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000071 elementor-widget elementor-widget-text-editor\" data-id=\"rt000071\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Fl\u00fcssigkeit kann zwischen dem Verfl\u00fcssiger und dem Dosierventil W\u00e4rme aufnehmen oder Druck verlieren. Beide Ver\u00e4nderungen k\u00f6nnen die lokale Unterk\u00fchlungsreserve verringern. Ein Wert am Verfl\u00fcssigeraustritt beweist daher nicht, dass dieselbe Reserve nach einer langen Leitung, einem vertikalen H\u00f6henunterschied, einem Filtertrockner oder einem Regelger\u00e4t noch vorhanden ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000072 elementor-widget elementor-widget-image\" data-id=\"rt000072\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed.webp\" class=\"attachment-full size-full wp-image-7291\" alt=\"Komponenten einer K\u00e4lteanlage mit Kupferrohren und Ventilen f\u00fcr HLK-Anwendungen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000073 elementor-widget elementor-widget-text-editor\" data-id=\"rt000073\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Copelands <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEB&amp;PDF=1212\" target=\"_blank\" rel=\"noopener\"><u>Technisches Merkblatt zur Receiver-Auslegung AE17-1212<\/u><\/a> beschreibt Fl\u00fcssigkeit nahe dem S\u00e4ttigungszustand in einem teilweise gef\u00fcllten Fl\u00fcssigkeitssammler sowie das Risiko einer Flashgasbildung nach einem Druckverlust. Bewerten Sie die Reserve an der relevanten Stelle anhand des dortigen Drucks und der dortigen Temperatur, anstatt einen Wert vom Verfl\u00fcssigeraustritt auf die gesamte Anlage zu \u00fcbertragen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000074 elementor-widget elementor-widget-text-editor\" data-id=\"rt000074\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn ein Fl\u00fcssigkeitssammler oder ein separater Unterk\u00fchler installiert ist, stellen Sie ihn in der Messskizze dar. Befolgen Sie das Bef\u00fcllungs- und F\u00fcllstandverfahren des Herstellers, anstatt die Unterk\u00fchlung am Verfl\u00fcssiger als universellen Indikator f\u00fcr den K\u00e4ltemittelbestand zu betrachten. Vergleichen Sie bei der Bewertung der Pr\u00fcfberichte zweier Lieferanten jeweils Messwerte von vergleichbaren Stellen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000075 elementor-widget elementor-widget-text-editor\" data-id=\"rt000075\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Unterscheidung wirkt sich auch auf die Angebotsanfrage (RFQ) aus. Fragen Sie, ob die angegebene Verfl\u00fcssigerleistung einen spezifizierten Unterk\u00fchlungsabschnitt umfasst und an welcher Stelle der Zustand des gelieferten Fl\u00fcssigk\u00e4ltemittels definiert ist. Gehen Sie nicht davon aus, dass eine Vergr\u00f6\u00dferung der Verfl\u00fcssigerfl\u00e4che ein nachgelagertes Rohrleitungsproblem behebt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b1 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000076 elementor-widget elementor-widget-heading\" data-id=\"rt000076\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"could-airflow-or-frosting-be-causing-the-complaint\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">K\u00f6nnten Luftstrom oder Vereisung die Beanstandung verursachen?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000077 elementor-widget elementor-widget-text-editor\" data-id=\"rt000077\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine Verdampferregistereinheit ist sowohl auf die Luftseite als auch auf die K\u00e4ltemittelversorgung angewiesen. \u00dcberpr\u00fcfen Sie den Ventilatorbetrieb, den R\u00fcckluftweg, die Produktbeladung, den Zustand der Lamellen und den Vereisungszustand, bevor Sie entscheiden, dass das Register eine h\u00f6here Leistung ben\u00f6tigt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000078 elementor-widget elementor-widget-image\" data-id=\"rt000078\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check.webp\" class=\"attachment-full size-full wp-image-7292\" alt=\"Vergleich von sauberen und vereisten Verdampferregistern hinsichtlich ihrer Effizienz.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000079 elementor-widget elementor-widget-text-editor\" data-id=\"rt000079\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine blockierte Verdampferfl\u00e4che ver\u00e4ndert die auf das K\u00e4ltemittel \u00fcbertragene Last. Die daraus resultierende \u00dcberhitzungsreaktion h\u00e4ngt vom Dosierventil und der Regelung ab. Ein TXV kann dies teilweise ausgleichen. Daher beweist ein scheinbar akzeptabler \u00dcberhitzungswert weder einen ausreichenden Luftstrom noch eine ausreichende nutzbare K\u00fchlleistung des Schranks.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007a elementor-widget elementor-widget-text-editor\" data-id=\"rt00007a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Untersuchen Sie ebenso den Luftstrom am Verfl\u00fcssiger und die Eintrittsbedingungen, wenn die W\u00e4rmeabgabe unzureichend ist. Halten Sie die Beobachtungen getrennt: Eine verschmutzte Registeroberfl\u00e4che ist ein sichtbarer Befund; ihre gemessene Auswirkung auf die Leistung muss anhand von Betriebsdaten ermittelt werden. Der <a href=\"https:\/\/domirefrigeration.com\/de\/verflussigerwendel\/\"><u>Leitfaden f\u00fcr Kondensatorspulen<\/u><\/a> behandelt die getrennten Fragen zu Wartung und Konstruktion.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007b elementor-widget elementor-widget-text-editor\" data-id=\"rt00007b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei einer Anfrage zum Austausch stellen Sie bitte Fotos des installierten Luftstr\u00f6mungswegs sowie der ausgebauten Verdampferschlange bereit. Eine neue Verdampferschlange mit denselben Abmessungen wie die alte kann denselben Bypass-Spalt oder denselben blockierten R\u00fcckluftweg aufweisen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b2 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007c elementor-widget elementor-widget-heading\" data-id=\"rt00007c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"record-a-stable-operating-condition\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Einen stabilen Betriebszustand aufzeichnen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007d elementor-widget elementor-widget-text-editor\" data-id=\"rt00007d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Messwerte, die w\u00e4hrend des Anlaufs, des Herunterk\u00fchlens, der Abtau-Erholung, des zyklischen L\u00fcfterbetriebs oder einer Leistungs\u00e4nderung erfasst werden, sollten mit dem jeweiligen Betriebszustand gekennzeichnet werden. Vergleichen Sie diese nicht mit einem Sollwert f\u00fcr den station\u00e4ren Betrieb, es sei denn, das Verfahren des Herstellers sieht dies ausdr\u00fccklich vor.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007e elementor-widget elementor-widget-image\" data-id=\"rt00007e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test.webp\" class=\"attachment-full size-full wp-image-7293\" alt=\"Labork\u00fchlschrank zur Aufbewahrung bunter Glasflaschen in einer modernen Laborumgebung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007f elementor-widget elementor-widget-text-editor\" data-id=\"rt00007f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr einen OEM-Vergleich w\u00e4hlen Sie ein klar definiertes Testzeitfenster und protokollieren Sie die zusammengeh\u00f6rigen Messwerte gemeinsam mit der Umgebungstemperatur, dem Zustand des Schranks oder Raums, dem L\u00fcfterzustand, dem Kompressorzustand und, sofern verf\u00fcgbar, dem Verhalten des Ventils. Verwenden Sie das Ger\u00e4teverfahren, um die Stabilisierung zu bestimmen. Eine allgemeing\u00fcltige Wartezeit ist nicht f\u00fcr jedes System geeignet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000080 elementor-widget elementor-widget-text-editor\" data-id=\"rt000080\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein stabiler Durchschnittswert kann gro\u00dfe Schwankungen verbergen. Bewahren Sie bei der Untersuchung von Regelungsschwankungen oder zeitweise niedriger \u00dcberhitzung den Wertebereich oder den zeitlichen Messverlauf auf. Tritt das Ereignis nur nach dem \u00d6ffnen einer T\u00fcr oder nach dem Abtauen auf, behalten Sie dieses Ereignis in der Testdokumentation bei, anstatt es durch Mittelwertbildung zu eliminieren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b3 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000081 elementor-widget elementor-widget-heading\" data-id=\"rt000081\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"worked-oem-example-check-the-probe-before-changing-the-coil\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Praktisches OEM-Beispiel: Pr\u00fcfen Sie den Messf\u00fchler, bevor Sie die Verdampferschlange austauschen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000082 elementor-widget elementor-widget-text-editor\" data-id=\"rt000082\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Angenommen, ein Entwicklungsschrank verf\u00fcgt \u00fcber einen <strong>hypothetischen genehmigten Pr\u00fcfzielwert<\/strong> f\u00fcr eine \u00dcberhitzung am Verdampferausgang von 6 \u00b1 1 K und eine Unterk\u00fchlung am Ventileingang von 6 bis 10 K bei einem definierten Betriebspunkt. Diese Grenzwerte sind f\u00fcr dieses Beispiel frei erfunden und d\u00fcrfen nicht als Sollwerte f\u00fcr den praktischen Einsatz verwendet werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000083 elementor-widget elementor-widget-text-editor\" data-id=\"rt000083\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der erste Datensatz zeigt die zuvor erl\u00e4uterten Lehrwerte: 16 \u00b0C Austrittstemperatur, 4 \u00b0C Taupunkt-Referenztemperatur und somit 12 K \u00dcberhitzung. Die Unterk\u00fchlung am Ventileingang betr\u00e4gt 8 K. Das Team schl\u00e4gt einen gr\u00f6\u00dferen Verdampfer vor, da die gemessene \u00dcberhitzung zu hoch ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000084 elementor-widget elementor-widget-text-editor\" data-id=\"rt000084\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Pr\u00fcfschritte sind:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000085 elementor-widget elementor-widget-text-editor\" data-id=\"rt000085\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li>Best\u00e4tigen Sie, dass sich Druck- und Temperaturmessung auf dieselbe Austrittsposition beziehen.<\/li>\n<li>\u00dcberpr\u00fcfen Sie das K\u00e4ltemittel und die Taupunkteinstellung.<\/li>\n<li>Vergleichen Sie den Anlegef\u00fchler unter demselben Betriebszustand mit einer unabh\u00e4ngigen Messung.<\/li>\n<li>\u00dcberpr\u00fcfen Sie das Ergebnis erneut, nachdem die Messf\u00fchlerinstallation korrigiert wurde.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000086 elementor-widget elementor-widget-text-editor\" data-id=\"rt000086\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Angenommen, diese Untersuchung ergibt einen schlechten Kontakt des Messf\u00fchlers. Beim hypothetischen Wiederholungstest zeigt der korrekt installierte Messf\u00fchler 10 \u00b0C an, w\u00e4hrend die lokale Taupunkt-Referenztemperatur weiterhin 4 \u00b0C betr\u00e4gt. Die berechnete \u00dcberhitzung liegt nun bei 6 K und damit innerhalb des f\u00fcr dieses Beispiel genehmigten Bereichs, ohne dass eine \u00c4nderung an der Verdampferschlange vorgenommen wurde.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000087 elementor-widget elementor-widget-text-editor\" data-id=\"rt000087\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die \u00c4nderung von 12 K auf 6 K hat ein Messproblem behoben. Sie hat keine Verbesserung der Verdampferleistung nachgewiesen. Wenn der Schrank seine Temperaturanforderungen weiterhin nicht erf\u00fcllt, untersuchen Sie die verbleibende W\u00e4rmelast, den Luftstrom, die Regelung und die Systemleistung anhand des korrigierten Datensatzes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b4 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000088 elementor-widget elementor-widget-heading\" data-id=\"rt000088\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"build-a-coil-review-packet-from-the-measurements\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Erstellen Sie anhand der Messwerte eine Pr\u00fcfunterlage f\u00fcr die Verdampferschlange<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000089 elementor-widget elementor-widget-text-editor\" data-id=\"rt000089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Sobald die vorliegenden Nachweise weiterhin auf ein Problem mit einer Komponente hindeuten, verkn\u00fcpfen Sie das Betriebsprotokoll mit der tats\u00e4chlich verwendeten Verdampferschlange. Geben Sie auch den Revisionsstand der Zeichnung an, damit der Lieferant die thermische Beanstandung dem zu pr\u00fcfenden Bauteil zuordnen kann.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008a elementor-widget elementor-widget-image\" data-id=\"rt00008a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release.webp\" class=\"attachment-full size-full wp-image-7294\" alt=\"Industrielle K\u00e4ltekomponente mit technischen Zeichnungen und Messwerkzeugen.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008b elementor-widget elementor-widget-text-editor\" data-id=\"rt00008b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Enthalten Sie:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008c elementor-widget elementor-widget-text-editor\" data-id=\"rt00008c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Ger\u00e4temodell, vorgesehener Anwendungsbereich, K\u00e4ltemittel und Dosiereinrichtung.<\/li>\n<li>Messskizze, lokale Dr\u00fccke, Rohrtemperaturen, P-T-Referenz, berechnete Ergebnisse und geltende Sollwerte.<\/li>\n<li>Betriebszustand, Umgebungstemperatur, Last, L\u00fcfterleistung, Vereisungs-\/Abtauzustand und gegebenenfalls der Trend der Reglerdaten.<\/li>\n<li>Registerzeichnung und Revisionsstand, Abmessungen, Rohr- und Lamellenanordnung, Kreisl\u00e4ufe, Anschl\u00fcsse und Montageanschl\u00fcsse.<\/li>\n<li>Erforderliche K\u00fchl- oder W\u00e4rmeabfuhrleistung, zul\u00e4ssige Druckverluste und der Abnahmetest des Musters.<\/li>\n<li>Mustermenge, gesch\u00e4tzte Produktionsmenge, Bestimmungsort und erforderliche Pr\u00fcfdokumente.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008d elementor-widget elementor-widget-text-editor\" data-id=\"rt00008d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Geben Sie an, welche Werte gemessen, welche berechnet und welche als Sollwerte vorgegeben werden. Wenn eine gr\u00f6\u00dfere Stirnfl\u00e4che oder eine andere Kreislaufkonfiguration vorgeschlagen wird, bitten Sie den Lieferanten, die Auswirkungen auf Luftstrom, Druckverlust, Passgenauigkeit und den vereinbarten Nennbetriebspunkt anzugeben. Das neue Design muss weiterhin entsprechend validiert werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b5 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008e elementor-widget elementor-widget-heading\" data-id=\"rt00008e\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufig gestellte Fragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008f elementor-widget elementor-widget-heading\" data-id=\"rt00008f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-is-the-difference-between-superheat-and-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was ist der Unterschied zwischen \u00dcberhitzung und Unterk\u00fchlung?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000090 elementor-widget elementor-widget-text-editor\" data-id=\"rt000090\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die \u00dcberhitzung gibt an, um wie viel die Dampftemperatur \u00fcber der lokalen S\u00e4ttigungstemperatur liegt. Die Unterk\u00fchlung gibt an, um wie viel die Fl\u00fcssigkeitstemperatur unter der lokalen S\u00e4ttigungstemperatur liegt. Beide Gr\u00f6\u00dfen beziehen sich auf unterschiedliche Bereiche des K\u00e4ltekreislaufs und verwenden entgegengesetzte Subtraktionsreihenfolgen. F\u00fcr beide werden das richtige K\u00e4ltemittel und der lokale Druck ben\u00f6tigt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000091 elementor-widget elementor-widget-heading\" data-id=\"rt000091\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-i-calculate-superheat-from-a-pressure-reading\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wie berechne ich die \u00dcberhitzung anhand eines Druckmesswerts?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000092 elementor-widget elementor-widget-text-editor\" data-id=\"rt000092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wandeln Sie den Druck mithilfe der S\u00e4ttigungsdampftemperatur des K\u00e4ltemittels in einen Temperaturwert um. Bei K\u00e4ltemittelgemischen verwenden Sie daf\u00fcr die Taupunktdaten. Ziehen Sie diesen Wert von der gemessenen Dampfleitungstemperatur an der entsprechenden Stelle ab. Der Druck allein reicht zur Bestimmung der \u00dcberhitzung nicht aus, da zus\u00e4tzlich die tats\u00e4chliche Rohrtemperatur ben\u00f6tigt wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000093 elementor-widget elementor-widget-heading\" data-id=\"rt000093\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"do-i-use-dew-or-bubble-for-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Verwende ich f\u00fcr die Unterk\u00fchlung den Taupunkt oder den Blasenpunkt?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000094 elementor-widget elementor-widget-text-editor\" data-id=\"rt000094\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Verwenden Sie die Referenztemperatur der ges\u00e4ttigten Fl\u00fcssigkeit beziehungsweise den Blasenpunkt beim gemessenen Fl\u00fcssigkeitsdruck. Ziehen Sie davon die gemessene Fl\u00fcssigkeitsleitungstemperatur ab. F\u00fcr die \u00dcberhitzung verwenden Sie den Taupunkt. Ein Mittelwert, der f\u00fcr Leistungsbewertungen vorgesehen ist, ist nicht automatisch ein geeigneter Ersatz f\u00fcr eine dieser Berechnungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000095 elementor-widget elementor-widget-heading\" data-id=\"rt000095\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-high-superheat-and-low-subcooling-always-mean-low-refrigerant-charge\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bedeuten eine hohe \u00dcberhitzung und eine niedrige Unterk\u00fchlung immer eine zu geringe K\u00e4ltemittelf\u00fcllmenge?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000096 elementor-widget elementor-widget-text-editor\" data-id=\"rt000096\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Diese Beobachtung kann bei einigen Anlagen auf eine unzureichende Fl\u00fcssigkeitsversorgung hindeuten, ist jedoch keine eindeutige Diagnose. \u00dcberpr\u00fcfen Sie die Messqualit\u00e4t, den Betriebszustand, die Systemarchitektur, die Bedingungen der Fl\u00fcssigkeitszufuhr und das vom Hersteller vorgeschriebene Verfahren zur \u00dcberpr\u00fcfung der K\u00e4ltemittelf\u00fcllmenge, bevor Sie entscheiden, welche Ma\u00dfnahme gerechtfertigt ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000097 elementor-widget elementor-widget-heading\" data-id=\"rt000097\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-high-subcooling-prove-a-liquid-line-restriction\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kann eine hohe Unterk\u00fchlung eine Verengung der Fl\u00fcssigkeitsleitung beweisen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000098 elementor-widget elementor-widget-text-editor\" data-id=\"rt000098\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Ihre Bedeutung h\u00e4ngt von der Messstelle und der Systemanordnung ab. \u00dcberpr\u00fcfen Sie die Druckverluste und den Fl\u00fcssigkeitszustand im Bereich der vermuteten Verengung sowie die Ventilfunktion und die Angaben zur K\u00e4ltemittelf\u00fcllmenge. Ein hoher Wert vor der vermuteten Verengung beschreibt nicht den Zustand der gesamten Fl\u00fcssigkeitsleitung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000099 elementor-widget elementor-widget-heading\" data-id=\"rt000099\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-evaporator-superheat-the-same-as-compressor-superheat\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ist die Verdampfer\u00fcberhitzung dasselbe wie die Verdichter\u00fcberhitzung?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009a elementor-widget elementor-widget-text-editor\" data-id=\"rt00009a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Sie werden an unterschiedlichen Stellen gemessen. W\u00e4rmeaufnahme und Druckverluste in der Saugleitung k\u00f6nnen die S\u00e4ttigungsreserve zwischen dem Verdampferaustritt und dem Verdichtereintritt ver\u00e4ndern. Dokumentieren Sie die jeweilige Messstelle und vergleichen Sie jeden Wert mit den geltenden Anforderungen f\u00fcr die Verdampferregelung beziehungsweise den Verdichter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009b elementor-widget elementor-widget-heading\" data-id=\"rt00009b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-use-the-same-targets-for-r-410a-r-32-and-r-454b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kann ich dieselben Sollwerte f\u00fcr R-410A, R-32 und R-454B verwenden?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009c elementor-widget elementor-widget-text-editor\" data-id=\"rt00009c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Gehen Sie nicht automatisch davon aus. Verwenden Sie die Druck-Temperatur-Daten des jeweiligen K\u00e4ltemittels sowie die Betriebsvorgaben des Ger\u00e4teherstellers. Die korrekte Druck-Temperatur-Umrechnung ist nur ein Teil der \u00dcberpr\u00fcfung. Die Sollwerte h\u00e4ngen au\u00dferdem vom Ger\u00e4temodell, dem Messort und den Betriebsbedingungen ab.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009d elementor-widget elementor-widget-heading\" data-id=\"rt00009d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"when-do-the-readings-justify-replacing-a-coil\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wann rechtfertigen die Messwerte den Austausch eines W\u00e4rmetauschers?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009e elementor-widget elementor-widget-text-editor\" data-id=\"rt00009e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn die verbleibenden Nachweise auf ein Problem mit dem W\u00e4rmetauscher hindeuten und der geplante Austausch dieses Problem behebt. \u00dcberpr\u00fcfen Sie zun\u00e4chst die Messqualit\u00e4t, den Luftstrom, die K\u00e4ltemittelversorgung und die Regelung. Vergleichen Sie anschlie\u00dfend die Bauweise und Nennleistung des W\u00e4rmetauschers mit den erforderlichen Betriebsanforderungen und legen Sie einen Test fest, mit dem sich die Funktion des Ersatzteils \u00fcberpr\u00fcfen l\u00e4sst.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b6 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009f elementor-widget elementor-widget-heading\" data-id=\"rt00009f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"make-the-next-decision-from-a-reproducible-record\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Treffen Sie die n\u00e4chste Entscheidung auf Grundlage einer nachvollziehbaren Dokumentation<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a0 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dokumentieren Sie den \u00f6rtlichen Druck, die Rohrtemperatur, das verwendete K\u00e4ltemittel, den Betriebszustand und die Sollwerte gemeinsam. \u00dcberpr\u00fcfen Sie die Messung erneut, bevor Sie ein Ventil, einen Verfl\u00fcssiger oder einen Verdampfer als Fehlerquelle einstufen. Diese Dokumentation ist f\u00fcr Service, Entwicklung und Beschaffung hilfreich, da jedes Team nachvollziehen kann, was die Messwerte belegen und welche Pr\u00fcfungen noch erforderlich sind.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b7 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a1 elementor-widget elementor-widget-heading\" data-id=\"rt0000a1\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"request-a-coil-review-with-the-operating-evidence\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fordern Sie eine Pr\u00fcfung des W\u00e4rmetauschers anhand der Betriebsdaten an<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a2 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Domis <a href=\"https:\/\/domirefrigeration.com\/de\/individuelle-registerfertigung\/\"><u>kundenspezifische W\u00e4rmetauscherfertigung<\/u><\/a> bietet eine M\u00f6glichkeit zur \u00dcberpr\u00fcfung von Zeichnungen, Mustern und Anwendungsanforderungen. Senden Sie bei einem Verdampfer- oder Verfl\u00fcssigerprojekt die aktuelle Zeichnungsrevision des W\u00e4rmetauschers zusammen mit dem Messprotokoll. Geben Sie an, ob Sie einen passgenauen Ersatz, eine erneute \u00dcberpr\u00fcfung der Auslegungsleistung oder einen Geometrievorschlag f\u00fcr ein OEM-Programm ben\u00f6tigen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a3 elementor-widget elementor-widget-image\" data-id=\"rt0000a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record.webp\" class=\"attachment-full size-full wp-image-7295\" alt=\"K\u00e4ltemittel-Servicewerkzeuge und eine Checkliste f\u00fcr die HVAC-Wartung.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a4 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Geben Sie die erforderliche Leistung, den verf\u00fcgbaren Luftstrom, die Druckverlustgrenzwerte, die K\u00e4ltemittelbedingungen und den verf\u00fcgbaren Einbauraum an. Domi kann die verf\u00fcgbaren Informationen pr\u00fcfen und die f\u00fcr eine Projektbesprechung erforderlichen Angaben ermitteln. Die endg\u00fcltige Konstruktion, Leistung, Pr\u00fcfumfang, Musterlieferzeit und kaufm\u00e4nnischen Bedingungen m\u00fcssen anhand der vereinbarten Spezifikation best\u00e4tigt werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a5 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"rt0000a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/de\/kontakt\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Senden Sie Ihre W\u00e4rmetauscherzeichnung und Ihr Pr\u00fcfprotokoll<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b8 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a6 elementor-widget elementor-widget-heading\" data-id=\"rt0000a6\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-refrigeration-resources\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Weitere Informationen zur K\u00e4ltetechnik<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a7 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/kaltekreislauf\/\"><u>K\u00e4ltemittelkreislauf: Die vier Phasen und die Funktionen der W\u00e4rmetauscher<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/leitfaden-fur-thermostatische-expansionsventile\/\"><u>Thermostatisches Expansionsventil: \u00dcberhitzung und Auswahl<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/elektronisches-expansionsventil-handbuch\/\"><u>Elektronisches Expansionsventil: Regelung und Auswahl<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/auslegung-von-gewerblichen-kaltemittelregistern\/\"><u>Dimensionierung von gewerblichen K\u00e4lteverdampfern<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/planungsleitfaden-fur-kaltemittelleitungen\/\"><u>Auslegung von K\u00e4ltemittelleitungen und OEM-Pr\u00fcfungen<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/individuelle-registerfertigung\/\"><u>Fertigung kundenspezifischer K\u00e4ltemittel-W\u00e4rmetauscher<\/u><\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A practical guide to paired pressure and temperature measurements, worked calculations, diagnostic limits, and the evidence OEM buyers need before changing a refrigeration coil.<\/p>","protected":false},"author":1,"featured_media":7283,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[54],"tags":[],"class_list":["post-7296","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oem-buyer-guides"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/comments?post=7296"}],"version-history":[{"count":6,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7296\/revisions"}],"predecessor-version":[{"id":7302,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7296\/revisions\/7302"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media\/7283"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media?parent=7296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/categories?post=7296"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/tags?post=7296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}