{"id":7451,"date":"2026-10-30T00:31:05","date_gmt":"2026-10-29T16:31:05","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7451"},"modified":"2026-10-30T00:31:05","modified_gmt":"2026-10-29T16:31:05","slug":"kuhlmittelregeln-fur-eismaschinen-2026","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/de\/ice-machine-refrigerant-rules-2026\/","title":{"rendered":"K\u00e4ltemittelregeln f\u00fcr Eismaschinen im Jahr 2026: EPA-Grenzwerte und R-290 OEM-\u00dcberpr\u00fcfung"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7451\" class=\"elementor elementor-7451\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000c5 e-con-full e-flex e-con e-parent\" data-id=\"rt0000c5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt0000b7 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000002 e-con-full e-flex e-con e-parent\" data-id=\"rt000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000001 elementor-widget elementor-widget-text-editor\" data-id=\"rt000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die EPA verlangt im Jahr 2026 nicht, dass jede kommerzielle Eismaschine R-290 verwendet. Ihre Herstellungs- und Importbeschr\u00e4nkung ab dem 1. Januar 2026 betrifft selbstenthaltene Chargenmaschinen mit 1.000 lb\/24 h oder weniger und selbstenthaltene kontinuierliche Maschinen mit 1.200 lb\/24 h oder weniger, mit einem GWP-Grenzwert von 150. Andere Kategorien haben unterschiedliche Beschr\u00e4nkungen. R-290 ist eine Option mit Endverbrauchs- und Sicherheitsbedingungen. Siehe die <a href=\"https:\/\/www.epa.gov\/hfcs\/technology-transitions-hfc-restrictions-sector\" target=\"_blank\" rel=\"noopener\"><u>EPA-Sektorbeschr\u00e4nkungen<\/u><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000003 elementor-widget elementor-widget-text-editor\" data-id=\"rt000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Produktmanager eines OEM muss wissen, welche Regel auf die Maschine zutrifft und welche Nachweise eine Konstruktions\u00e4nderung unterst\u00fctzen. Ein K\u00e4ltemittelname auf einem Angebot kann keine der beiden Fragen beantworten. Bestimmen Sie zuerst die Maschinenarchitektur, das Eisherstellungsverfahren, die t\u00e4gliche Erntkategorie und den vorgesehenen Markt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000004 elementor-widget elementor-widget-text-editor\" data-id=\"rt000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dieser Leitfaden deckt Programme f\u00fcr kommerzielle Eismaschinen in Deutschland ab. Er trennt regulatorische Anforderungen von vorgeschlagenen technischen \u00dcberpr\u00fcfungsschritten. Ger\u00e4teabbildungen erkl\u00e4ren Konzepte; sie sind keine Fotos eines zertifizierten Produkts oder Aufzeichnungen von Domi-Tests.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000005 elementor-widget elementor-widget-text-editor\" data-id=\"rt000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Springen zu <a href=\"#which-ice-machines-fall-under-the-2026-epa-limits\"><u>Ger\u00e4tekategorien<\/u><\/a>, <a href=\"#is-r-290-mandatory-for-every-ice-machine\"><u>R-290-Bedingungen<\/u><\/a>, <a href=\"#what-should-change-in-the-coil-brief\"><u>Spulen\u00e4nderungen<\/u><\/a>, <a href=\"#does-every-coil-need-recertification\"><u>Zertifizierungsumfang<\/u><\/a>, <a href=\"#use-four-release-gates-before-approving-the-change\"><u>Freigabetore<\/u><\/a> oder <a href=\"#what-belongs-in-an-ice-machine-coil-rfq\"><u>Anforderungen an die Angebotsanfrage (RFQ)<\/u><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b8 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000006 elementor-widget elementor-widget-heading\" data-id=\"rt000006\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"which-ice-machines-fall-under-the-2026-epa-limits\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Welche Eismaschinen fallen unter die EPA-Grenzwerte von 2026?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000007 elementor-widget elementor-widget-text-editor\" data-id=\"rt000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beginnen Sie damit, wie die Ausr\u00fcstung zu einem funktionierenden K\u00fchlschrankger\u00e4t wird. Eine werkseitig vollst\u00e4ndige selbstenthaltene Maschine unterscheidet sich von Ausr\u00fcstung, die vor Ort zusammengebaut oder mit K\u00e4ltemittel bef\u00fcllt wird. Die EPA erkl\u00e4rt diesen Unterschied in ihren <a href=\"https:\/\/www.epa.gov\/hfcs\/frequent-questions-phasedown-hydrofluorocarbons\" target=\"_blank\" rel=\"noopener\"><u>Produkt- versus Systemfragen<\/u><\/a>. Eine Ferninstallation sollte die Kategorie selbstenthalten nicht nur deshalb erben, weil ihre Eisherstellung unter einem bekannten Schwellenwert liegt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000008 elementor-widget elementor-widget-image\" data-id=\"rt000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture.webp\" class=\"attachment-full size-full wp-image-7441\" alt=\"Domi K\u00e4ltetechnik selbstenthaltendes und Fernsystem mit industrieller K\u00fchlanlage aus Kupfer, Silber.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-architecture-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000009 elementor-widget elementor-widget-text-editor\" data-id=\"rt000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Architekturdarstellung: Bestimmen Sie die Grenzen der Fabrik- und Feldmontage, bevor Sie eine regulatorische Kategorie zuweisen.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000a elementor-widget elementor-widget-text-editor\" data-id=\"rt00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Folgende ist eine kurze Klassifikationshilfe. F\u00fcr Kategorien mit verbotenen Substanzen pr\u00fcfen Sie die vollst\u00e4ndige K\u00e4ltemittelliste, anstatt die GWP-Grenze f\u00fcr kleinere Maschinen anzuwenden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000041 e-con-full e-flex e-con e-parent\" data-id=\"rt000041\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000013 e-con-full elementor-hidden-mobile e-flex e-con e-parent\" data-id=\"rt000013\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00000c e-con-full e-flex e-con e-parent\" data-id=\"rt00000c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000b elementor-widget elementor-widget-text-editor\" data-id=\"rt00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ger\u00e4tekategorie<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00000e e-con-full e-flex e-con e-parent\" data-id=\"rt00000e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000d elementor-widget elementor-widget-text-editor\" data-id=\"rt00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>T\u00e4gliche Eisherstellung<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000010 e-con-full e-flex e-con e-parent\" data-id=\"rt000010\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000f elementor-widget elementor-widget-text-editor\" data-id=\"rt00000f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Beschr\u00e4nkungsgrundlage<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000012 e-con-full e-flex e-con e-parent\" data-id=\"rt000012\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000011 elementor-widget elementor-widget-text-editor\" data-id=\"rt000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Einhaltungsereignis und Datum<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001c e-con-full e-flex e-con e-parent\" data-id=\"rt00001c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000015 e-con-full e-flex e-con e-parent\" data-id=\"rt000015\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000014 elementor-widget elementor-widget-text-editor\" data-id=\"rt000014\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ger\u00e4tekategorie:<\/strong> Eigenst\u00e4ndig, Batch<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000017 e-con-full e-flex e-con e-parent\" data-id=\"rt000017\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000016 elementor-widget elementor-widget-text-editor\" data-id=\"rt000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>T\u00e4gliche Eisherstellung:<\/strong> Bis zu 1.000 lb\/24 h<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000019 e-con-full e-flex e-con e-parent\" data-id=\"rt000019\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000018 elementor-widget elementor-widget-text-editor\" data-id=\"rt000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Restriktionsgrundlage:<\/strong> GWP-Grenzwert 150<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001b e-con-full e-flex e-con e-parent\" data-id=\"rt00001b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001a elementor-widget elementor-widget-text-editor\" data-id=\"rt00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Einhaltungsereignis und Datum:<\/strong> Herstellung\/Import: 1. Januar 2026<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000025 e-con-full e-flex e-con e-parent\" data-id=\"rt000025\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00001e e-con-full e-flex e-con e-parent\" data-id=\"rt00001e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001d elementor-widget elementor-widget-text-editor\" data-id=\"rt00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ger\u00e4tekategorie:<\/strong> Eigenst\u00e4ndig, kontinuierlich<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000020 e-con-full e-flex e-con e-parent\" data-id=\"rt000020\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001f elementor-widget elementor-widget-text-editor\" data-id=\"rt00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>T\u00e4gliche Eisherstellung:<\/strong> Bis zu 1.200 lb\/24 h<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000022 e-con-full e-flex e-con e-parent\" data-id=\"rt000022\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000021 elementor-widget elementor-widget-text-editor\" data-id=\"rt000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Restriktionsgrundlage:<\/strong> GWP-Grenzwert 150<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000024 e-con-full e-flex e-con e-parent\" data-id=\"rt000024\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000023 elementor-widget elementor-widget-text-editor\" data-id=\"rt000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Einhaltungsereignis und Datum:<\/strong> Herstellung\/Import: 1. Januar 2026<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00002e e-con-full e-flex e-con e-parent\" data-id=\"rt00002e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000027 e-con-full e-flex e-con e-parent\" data-id=\"rt000027\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000026 elementor-widget elementor-widget-text-editor\" data-id=\"rt000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ger\u00e4tekategorie:<\/strong> Eigenst\u00e4ndig, Batch<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000029 e-con-full e-flex e-con e-parent\" data-id=\"rt000029\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000028 elementor-widget elementor-widget-text-editor\" data-id=\"rt000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>T\u00e4gliche Eisherstellung:<\/strong> \u00dcber 1.000 lb\/24 h<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00002b e-con-full e-flex e-con e-parent\" data-id=\"rt00002b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002a elementor-widget elementor-widget-text-editor\" data-id=\"rt00002a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Restriktionsgrundlage:<\/strong> Benannte K\u00e4ltemittel verboten<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00002d e-con-full e-flex e-con e-parent\" data-id=\"rt00002d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002c elementor-widget elementor-widget-text-editor\" data-id=\"rt00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Einhaltungsereignis und Datum:<\/strong> Herstellung\/Import: 1. Januar 2027<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000037 e-con-full e-flex e-con e-parent\" data-id=\"rt000037\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000030 e-con-full e-flex e-con e-parent\" data-id=\"rt000030\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002f elementor-widget elementor-widget-text-editor\" data-id=\"rt00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ger\u00e4tekategorie:<\/strong> Eigenst\u00e4ndig, kontinuierlich<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000032 e-con-full e-flex e-con e-parent\" data-id=\"rt000032\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000031 elementor-widget elementor-widget-text-editor\" data-id=\"rt000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>T\u00e4gliche Eisherstellung:<\/strong> \u00dcber 1.200 lb\/24 h<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000034 e-con-full e-flex e-con e-parent\" data-id=\"rt000034\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000033 elementor-widget elementor-widget-text-editor\" data-id=\"rt000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Restriktionsgrundlage:<\/strong> Benannte K\u00e4ltemittel verboten<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000036 e-con-full e-flex e-con e-parent\" data-id=\"rt000036\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000035 elementor-widget elementor-widget-text-editor\" data-id=\"rt000035\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Einhaltungsereignis und Datum:<\/strong> Herstellung\/Import: 1. Januar 2027<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000040 e-con-full e-flex e-con e-parent\" data-id=\"rt000040\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000039 e-con-full e-flex e-con e-parent\" data-id=\"rt000039\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000038 elementor-widget elementor-widget-text-editor\" data-id=\"rt000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ger\u00e4tekategorie:<\/strong> Fernbedientes gewerbliches Eismaschinensystem<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00003b e-con-full e-flex e-con e-parent\" data-id=\"rt00003b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003a elementor-widget elementor-widget-text-editor\" data-id=\"rt00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>T\u00e4gliche Eisherstellung:<\/strong> Alle Erntes\u00e4tze<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00003d e-con-full e-flex e-con e-parent\" data-id=\"rt00003d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003c elementor-widget elementor-widget-text-editor\" data-id=\"rt00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Restriktionsgrundlage:<\/strong> Separates Verbotene-K\u00e4ltemittel-Liste<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00003f e-con-full e-flex e-con e-parent\" data-id=\"rt00003f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003e elementor-widget elementor-widget-text-editor\" data-id=\"rt00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Einhaltungsereignis und Datum:<\/strong> Installation: 1. Januar 2027<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000042 elementor-widget elementor-widget-text-editor\" data-id=\"rt000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Kategorien und ihre unterschiedlichen Beschr\u00e4nkungsformate werden ebenfalls im <a href=\"https:\/\/www.govinfo.gov\/content\/pkg\/FR-2023-10-24\/pdf\/2023-22529.pdf\" target=\"_blank\" rel=\"noopener\"><u>Endg\u00fcltigen Regelwerk der Technologie\u00fcberg\u00e4nge 2023<\/u><\/a>. erkl\u00e4rt. Verwenden Sie die aktuelle EPA-Sektorseite, wenn Sie nachfolgenden \u00c4nderungen nachgehen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000043 elementor-widget elementor-widget-text-editor\" data-id=\"rt000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei den kleineren, eigenst\u00e4ndigen Kategorien umfasst das Verbot regulierte HFCs und Mischungen, die sie enthalten, bei GWP 150 oder h\u00f6her. Der Schwellenwert von 150 bedeutet nicht die Erlaubnis, eine abgedeckte Mischung mit genau GWP 150 zu verwenden. Siehe <a href=\"https:\/\/www.ecfr.gov\/current\/title-40\/chapter-I\/subchapter-C\/part-84\/subpart-B\/section-84.54\" target=\"_blank\" rel=\"noopener\"><u>40 CFR 84.54<\/u><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000044 elementor-widget elementor-widget-image\" data-id=\"rt000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds.webp\" class=\"attachment-full size-full wp-image-7442\" alt=\"Industrielle Eismaschine im Betrieb f\u00fcr Batch- und Dauerbetrieb mit schnee\u00e4hnlichen Eisw\u00fcrfeln.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-thresholds-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000045 elementor-widget elementor-widget-text-editor\" data-id=\"rt000045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Illustration der Produktionskategorie: Batch- und Kontinuierliche Maschinen haben unterschiedliche Erntegrenzwerte.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000046 elementor-widget elementor-widget-text-editor\" data-id=\"rt000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Betrachten Sie drei hypothetische Programme. Eine vollst\u00e4ndig in der Fabrik montierte Batch-Maschine mit einer Bewertung von 900 lb\/Tag geh\u00f6rt in die kleinere Batch-\u00dcberpr\u00fcfung. Eine eigenst\u00e4ndige kontinuierliche Maschine mit 1.100 lb\/Tag geh\u00f6rt trotz \u00dcberschreitung von 1.000 lb\/Tag weiterhin in die kleinere kontinuierliche \u00dcberpr\u00fcfung. Ein ferngesteuertes System, das vor Ort zusammengebaut wurde, mit 900 lb\/Tag ben\u00f6tigt die Systemklassifizierung. Diese Beispiele erkl\u00e4ren die Klassifizierungslogik; sie sind keine Modellgenehmigungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b9 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000047 elementor-widget elementor-widget-heading\" data-id=\"rt000047\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-r-290-mandatory-for-every-ice-machine\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ist R-290 f\u00fcr jede Eismaschine verpflichtend?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000048 elementor-widget elementor-widget-text-editor\" data-id=\"rt000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Eine Begrenzung des K\u00e4ltemittel-GWP schreibt nicht vor, dass f\u00fcr jedes Design ein bestimmtes K\u00e4ltemittel verwendet werden muss. EPA\u2019s <a href=\"https:\/\/www.epa.gov\/snap\/substitutes-commercial-ice-machines\" target=\"_blank\" rel=\"noopener\"><u>Kommerzielle Eismaschinen SNAP-Liste<\/u><\/a> kennzeichnet R-290, oder Propan, f\u00fcr neue eigenst\u00e4ndige Ger\u00e4te, die Nutzungsbedingungen unterliegen, und listet seine Sicherheitsgruppe als A3. Entflammbarkeit geh\u00f6rt in die Ger\u00e4tepr\u00fcfung. Die Endverbraucherauflistung muss zusammen mit den geltenden Technologie\u00fcbergangs-Beschr\u00e4nkungen gelesen werden; ein SNAP-Eintrag allein regelt nicht alle regulatorischen Anforderungen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000049 elementor-widget elementor-widget-text-editor\" data-id=\"rt000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Marktbeispiele zeigen, warum die Unterscheidung wichtig ist. Im Fall der <a href=\"https:\/\/www.secop.com\/solutions\/case-stories\/manitowoc-ice\" target=\"_blank\" rel=\"noopener\"><u>Manitowoc-Eismaschinenentwicklung<\/u><\/a>, beschreibt Secop einen speziell entwickelten R-290-Kompressor, eine Expansionsventil\u00e4nderung und einen Mikrokanal-Kondensator. Dies ist ein Beweis f\u00fcr einen Entwicklungsweg. Es legt nicht fest, dass jede Eismaschine dieses K\u00e4ltemittel verwenden oder diese Komponentenanordnung kopieren muss.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004a elementor-widget elementor-widget-text-editor\" data-id=\"rt00004a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein OEM, der Vorschl\u00e4ge vergleicht, sollte daher die Grundlage der K\u00e4ltemittelwahl und die entsprechenden Ger\u00e4teeinstellungen anfordern. Ein Anbieter, der eine R-290-kompatible Spule anbietet, ben\u00f6tigt noch das Betriebsumfeld und die Schnittstellenspezifikation der Maschine, bevor er einen n\u00fctzlichen Vorschlag machen kann.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ba e-con-full e-flex e-con e-parent\" data-id=\"rt0000ba\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004b elementor-widget elementor-widget-heading\" data-id=\"rt00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"which-approvals-belong-in-an-oem-review\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Welche Genehmigungen geh\u00f6ren in eine OEM-\u00dcberpr\u00fcfung?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004c elementor-widget elementor-widget-text-editor\" data-id=\"rt00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Halten Sie vier Aufzeichnungen getrennt: die geltende K\u00e4ltemittelbeschr\u00e4nkung, die Endverbraucherauflistung und -bedingungen, die Sicherheitsbewertung des Ger\u00e4ts und die Konstruktionsfreigabe des OEM. Jede Aufzeichnung beantwortet eine andere Frage. Ein Eintrag in der ersten Datei sollte nicht als Ersatz f\u00fcr die anderen drei verwendet werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004d elementor-widget elementor-widget-image\" data-id=\"rt00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers.webp\" class=\"attachment-full size-full wp-image-7443\" alt=\"Domi K\u00fchlschrankkomponenten und technische Schaltpl\u00e4ne auf einer Werkbank f\u00fcr HLK-Systeme.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rule-layers-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004e elementor-widget elementor-widget-text-editor\" data-id=\"rt00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>\u00dcberwachungsillustration: Die vier Dokumente unterst\u00fctzen unterschiedliche Entscheidungen und k\u00f6nnen unterschiedliche verantwortliche Parteien betreffen.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004f elementor-widget elementor-widget-text-editor\" data-id=\"rt00004f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zum Beispiel stellt eine zufriedenstellende thermische Probe keine Akzeptanz f\u00fcr Z\u00fcndquellen dar. UL Solutions beschreibt <a href=\"https:\/\/www.ul.com\/insights\/electrical-controls-use-refrigeration-and-air-conditioning-equipment-employing-flammable-refrigerants\" target=\"_blank\" rel=\"noopener\"><u>Elektrische Steuerungsbewertungen f\u00fcr brennbare K\u00e4ltemittel<\/u><\/a>, einschlie\u00dflich potenzieller Lichtb\u00f6gen und hei\u00dfer Oberfl\u00e4chen unter normalen und abnormalen Bedingungen. Diese Arbeit geht \u00fcber die Dimensionen einer Kondensatorspule hinaus.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000050 elementor-widget elementor-widget-text-editor\" data-id=\"rt000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Weisen Sie jedem Entscheid einen Verantwortlichen zu. Der K\u00e4lteanlageningenieur legt die Betriebsgrundlage fest, der Ger\u00e4tehersteller koordiniert das vollst\u00e4ndige Design, die relevante Zertifizierungsstelle bestimmt den Bewertungsumfang, und die Beschaffung bestellt die freigegebene Revision. Dokumentieren Sie diese Verantwortlichkeiten im Projektprotokoll, damit der Umfang eines Komponentenangebots klar ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000bb e-con-full e-flex e-con e-parent\" data-id=\"rt0000bb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000051 elementor-widget elementor-widget-heading\" data-id=\"rt000051\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-changes-for-existing-machines-and-spare-coils\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was \u00e4ndert sich bei bestehenden Maschinen und Ersatzspulen?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000052 elementor-widget elementor-widget-text-editor\" data-id=\"rt000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Termin f\u00fcr die Konformit\u00e4t neuer Ger\u00e4te ist keine Anweisung, jede bereits in Betrieb befindliche Maschine zu entleeren. EPA\u2019s <a href=\"https:\/\/www.epa.gov\/hfcs\/frequent-questions-phasedown-hydrofluorocarbons\" target=\"_blank\" rel=\"noopener\"><u>Fragen zum HFC-Reduktion<\/u><\/a> unterscheiden zwischen fortgesetzter Ger\u00e4teverwendung und Beschr\u00e4nkungen f\u00fcr neue Produkte und Systeme. Ein K\u00e4ltemittelwechsel allein berechtigt auch nicht zur Umr\u00fcstung bestehender Ger\u00e4te auf Propan.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000053 elementor-widget elementor-widget-image\" data-id=\"rt000053\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary.webp\" class=\"attachment-full size-full wp-image-7444\" alt=\"Domi K\u00fchlschrank-Gewerbeanzeigen und Au\u00dfenfernsteuerungssysteminstallation.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-date-boundary-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000054 elementor-widget elementor-widget-text-editor\" data-id=\"rt000054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Datumsabbildung: Die beiden Meilensteine beschreiben unterschiedliche Ger\u00e4tekategorien und Konformit\u00e4tsereignisse, nicht eine universelle Austauschfrist.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000055 elementor-widget elementor-widget-text-editor\" data-id=\"rt000055\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bei einer Ersatzspulenbestellung dokumentieren Sie zun\u00e4chst, ob die Arbeit eine bestimmte bestehende Maschine repariert oder ein neues Ger\u00e4teprogramm unterst\u00fctzt. Einschlie\u00dflich des Originalmodells, K\u00e4ltemittel, Konstruktionsrevision, Anschlussdetails und Servicezweck. Wenn die Arbeit das K\u00e4ltemittel \u00e4ndert oder die Ger\u00e4te wesentlich modifiziert, bitten Sie den Ger\u00e4tehersteller und den relevanten Pr\u00fcfer, das Projekt vor dem Teilekauf zu definieren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000056 elementor-widget elementor-widget-text-editor\" data-id=\"rt000056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine Spule, die physisch in den Schrank passt, kann dennoch unterschiedliche Schaltkreise, Volumen oder Druckcharakteristika auf der K\u00e4ltemittelseite aufweisen. Passen Sie den Ersatz an die dokumentierten Ger\u00e4teanforderungen an. Verwenden Sie die <a href=\"https:\/\/domirefrigeration.com\/de\/eismaschinen-verdampferspule\/\"><u>Leitfaden f\u00fcr Eisw\u00fcrfelmaschinen-Verdampfer<\/u><\/a> f\u00fcr die Komponenteninformationen, die in eine Ersatz\u00fcberpr\u00fcfung geh\u00f6ren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000bc e-con-full e-flex e-con e-parent\" data-id=\"rt0000bc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000057 elementor-widget elementor-widget-heading\" data-id=\"rt000057\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-change-in-the-coil-brief\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was sollte sich im Spulen-Expos\u00e9 \u00e4ndern?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000058 elementor-widget elementor-widget-text-editor\" data-id=\"rt000058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Behandeln Sie das vorgeschlagene K\u00e4ltemittel als eine technische Eingabe, nicht als eine Anweisung, die alte Zeichnung mit einem neuen Label wiederzuverwenden. Fixieren Sie den vorgesehenen Kompressor und das \u00d6l, Verdampfungs- und Kondensationsbedingungen, zul\u00e4ssige Betriebsdr\u00fccke, Luft- oder Wasserschutzraum, Steuerstrategie und Installationsumfeld. Identifizieren Sie, welche Werte festgelegt, berechnet oder noch validiert werden m\u00fcssen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000059 elementor-widget elementor-widget-image\" data-id=\"rt000059\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary.webp\" class=\"attachment-full size-full wp-image-7445\" alt=\"Domi K\u00fchlschrank-Gesamtbestandsliste: Verdampfer-, Kondensator- und Kompressorkomponenten.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-charge-boundary-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005a elementor-widget elementor-widget-text-editor\" data-id=\"rt00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Komponenteninventar-Illustration: Eine Spule ist ein Teil der Gesamtmaschinenbewertung. Dies ist kein K\u00e4ltemittelleitungsschema.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005b elementor-widget elementor-widget-text-editor\" data-id=\"rt00005b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fordern Sie das interne Volumen auf der K\u00e4ltemittelseite als separates Zeichnungsfeld an. Kopfbahnen, R\u00fcckbiegungen und verbundene Komponenten sind ebenso wichtig wie die gerade Rohrl\u00e4nge. Ein kleineres Kondensatorvolumen kann f\u00fcr das Projekt n\u00fctzlich sein, aber der Lieferant sollte die thermischen und Druckverlustkonsequenzen der vorgeschlagenen Geometrie erkl\u00e4ren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005c elementor-widget elementor-widget-text-editor\" data-id=\"rt00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Geben Sie die Frostzyklus-W\u00e4rmeabfuhrleistung des Kondensators an und alle anderen Bedingungen, die die Auswahl steuern. Definieren Sie die Eisschichtbildung auf der Verdampferfl\u00e4che, Wasserverteilung und Freigabebedingungen. Verwenden Sie die <a href=\"https:\/\/domirefrigeration.com\/de\/auswahl-des-kondensatorspulen-fur-eismaschinen\/\"><u>Kondensator-Auswahlliste f\u00fcr Eismaschinen<\/u><\/a> f\u00fcr die detaillierten Komponenten-Auswahlparameter neben dieser regulatorischen \u00dcberpr\u00fcfung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000bd e-con-full e-flex e-con e-parent\" data-id=\"rt0000bd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005d elementor-widget elementor-widget-heading\" data-id=\"rt00005d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"a-tube-volume-example-geometry-is-not-a-charge-allowance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ein Beispiel f\u00fcr das Volumen einer R\u00f6hre: Geometrie ist keine Ladungszulage<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005e elementor-widget elementor-widget-text-editor\" data-id=\"rt00005e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Betrachten Sie eine hypothetische geometrische \u00dcberpr\u00fcfung. Zwei gerade kreisf\u00f6rmige Rohre enthalten jeweils 4 m internen Durchgang. Eines hat einen Innendurchmesser von 6,0 mm; das andere einen Innendurchmesser von 4,5 mm. Das Beispiel schlie\u00dft Biegungen, Verteiler und Fertigungstoleranzen aus. Es w\u00e4hlt keine Spule aus und berechnet keine K\u00e4ltemittelladung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005f elementor-widget elementor-widget-text-editor\" data-id=\"rt00005f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr einen kreisf\u00f6rmigen Durchgang ist das Volumen V = \u03c0 \u00d7 Innendurchmesser\u00b2 \u00d7 L\u00e4nge \/ 4. Mit Durchmesser und L\u00e4nge in Metern ausgedr\u00fcckt:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000060 elementor-widget elementor-widget-text-editor\" data-id=\"rt000060\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Der Durchgang mit 6,0 mm enth\u00e4lt etwa 0,0001131 m\u00b3, oder 113,1 mL.<\/li>\n<li>Der Durchgang mit 4,5 mm enth\u00e4lt etwa 0,00006362 m\u00b3, oder 63,6 mL.<\/li>\n<li>Der kleinere Durchmesser reduziert dieses angenommene Durchflussvolumen um 43.75%.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000061 elementor-widget elementor-widget-image\" data-id=\"rt000061\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume.webp\" class=\"attachment-full size-full wp-image-7446\" alt=\"Kupferk\u00fchlrohre mit 6,0 mm Innendurchmesser und 4,5 mm Innendurchmesser, dargestellt auf der Website von Domi K\u00fchlschrank.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-tube-volume-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000062 elementor-widget elementor-widget-text-editor\" data-id=\"rt000062\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Geometrische Darstellung: gleicher Durchflussl\u00e4nge isoliert den Effekt des Innendurchmessers.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000063 elementor-widget elementor-widget-text-editor\" data-id=\"rt000063\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dieser Prozentsatz stellt keine entsprechende Reduktion der Systemladung dar. Zustand des K\u00e4ltemittels, Verteilung und der Rest des Kreislaufs sind in der Berechnung nicht enthalten. Es sagt auch nichts \u00fcber akzeptablen Druckverlust oder W\u00e4rme\u00fcbertragung aus. Verwenden Sie das Beispiel, um eine Volumenaufstellung anzufordern, und bewerten Sie dann den tats\u00e4chlichen Kreislauf mit dem verantwortlichen Ingenieur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000be e-con-full e-flex e-con e-parent\" data-id=\"rt0000be\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000064 elementor-widget elementor-widget-heading\" data-id=\"rt000064\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"freeze-and-harvest-need-separate-acceptance-limits\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Einfrieren und Ernten ben\u00f6tigen separate Abnahmelimits<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000065 elementor-widget elementor-widget-text-editor\" data-id=\"rt000065\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine Chargenmaschine muss zuverl\u00e4ssig Eis bilden und freigeben. Ein Spulenvorschlag, der an einem stabilen Betriebspunkt zufriedenstellend erscheint, kann dennoch eine ungel\u00f6ste \u00dcbergangsphase zwischen diesen Zust\u00e4nden hinterlassen. Der Musterplan sollte beides beschreiben, unter Verwendung der Steuersequenz und Betriebslimits des Herstellers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000066 elementor-widget elementor-widget-image\" data-id=\"rt000066\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest.webp\" class=\"attachment-full size-full wp-image-7447\" alt=\"Gefrier- und Erntesystem mit Eis gef\u00fclltem Gitter und Kupferrohren.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-freeze-harvest-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000067 elementor-widget elementor-widget-text-editor\" data-id=\"rt000067\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Betriebszustandsillustration: Die gleiche Eisschicht hat w\u00e4hrend des Einfrierens und Freigebens unterschiedliche Aufgaben.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000068 elementor-widget elementor-widget-text-editor\" data-id=\"rt000068\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Als vorgeschlagenes OEM-\u00dcberpr\u00fcfungsverfahren dokumentieren Sie die Testbedingungen, bevor Sie Muster vergleichen: Umgebungs- und Zulaufwasserbedingungen, Wasserverteilung, beabsichtigte Eiform, Startbedingungen und Steuerungsrevision. Definieren Sie die Akzeptanz f\u00fcr Produktionsrate, Zyklusverhalten und Freigabequalit\u00e4t. Kontinuierliche Maschinen ben\u00f6tigen ihren eigenen Betriebszustandsplan, anstatt eine Chargen-Erntefolge in die Spezifikation zu kopieren.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000069 elementor-widget elementor-widget-text-editor\" data-id=\"rt000069\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn zwei Lieferanten unter unterschiedlichen Bedingungen testen, fordern Sie eine gemeinsame Testgrundlage, bevor Sie ihre Ergebnisse vergleichen. Halten Sie gemessene Ergebnisse getrennt von Vorhersagen. Ein Angebot kann eine n\u00fctzliche Entwurfsabsch\u00e4tzung enthalten, erfordert jedoch eine vollst\u00e4ndige Maschinen\u00fcberpr\u00fcfung vor der Produktionsfreigabe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000bf e-con-full e-flex e-con e-parent\" data-id=\"rt0000bf\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006a elementor-widget elementor-widget-heading\" data-id=\"rt00006a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-every-coil-need-recertification\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Muss jede Spule neu zertifiziert werden?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006b elementor-widget elementor-widget-text-editor\" data-id=\"rt00006b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ein Kalendertag allein sagt einem OEM nicht, jede Spule oder Produktionslinie neu zu zertifizieren. Der <a href=\"https:\/\/www.govinfo.gov\/content\/pkg\/FR-2024-06-13\/pdf\/2024-11690.pdf\" target=\"_blank\" rel=\"noopener\"><u>2024 SNAP Endg\u00fcltige Regel<\/u><\/a> beinhaltet eine spezielle Behandlung von zuvor zertifizierten R-290-Designs, die unver\u00e4ndert bleiben, abgesehen von kosmetischen \u00c4nderungen. Die Bestimmung hat einen definierten Umfang; eine technische \u00c4nderung ben\u00f6tigt dennoch eine eigene \u00dcberpr\u00fcfung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006c elementor-widget elementor-widget-image\" data-id=\"rt00006c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control.webp\" class=\"attachment-full size-full wp-image-7448\" alt=\"Domi K\u00fchlschrank W\u00e4rmetauscher mit technischen Blaupausen und Messschiebern auf einer Holzwerkbank.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-revision-control-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006d elementor-widget elementor-widget-text-editor\" data-id=\"rt00006d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Revisionen-Illustration: Die \u00dcberpr\u00fcfung ben\u00f6tigt den tats\u00e4chlichen Unterschied zwischen dem genehmigten und dem vorgeschlagenen Design.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006e elementor-widget elementor-widget-text-editor\" data-id=\"rt00006e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>F\u00fcr ein konkretes Projekt erstellen Sie eine \u00c4nderungs\u00fcbersicht gegen\u00fcber dem bestehenden Bauaufzeichnungs. Identifizieren Sie K\u00e4ltemittel, Kompressor, Dosierger\u00e4t, Spulenschaltung, Material, Verbindungen, Innenvolumen, Steuerungen, Geh\u00e4use und Installations\u00e4nderungen. Fragen Sie die zust\u00e4ndige Zertifizierungsorganisation, welche \u00c4nderungen eine Bewertung oder Pr\u00fcfung erfordern, und erhalten Sie den Umfang schriftlich.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006f elementor-widget elementor-widget-text-editor\" data-id=\"rt00006f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>UL Solutions Listen <a href=\"https:\/\/www.ul.com\/services\/flammable-refrigerants-testing-air-conditioning-and-refrigeration\" target=\"_blank\" rel=\"noopener\"><u>Niedrig-GWP-Ger\u00e4te- und Komponentenbewertungsdienste<\/u><\/a>, einschlie\u00dflich Normen f\u00fcr gewerbliche K\u00fchlung und Eismaschinen. Die relevante Normausgabe, die Bedingungen und vorgeschlagene Konstruktion bestimmen die \u00dcberpr\u00fcfung. Ein Komponentenpr\u00fcfbericht sollte genau angeben, was er abdeckt; er sollte nicht als Genehmigung f\u00fcr die gesamte Maschine pr\u00e4sentiert werden.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000c0 e-con-full e-flex e-con e-parent\" data-id=\"rt0000c0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000070 elementor-widget elementor-widget-heading\" data-id=\"rt000070\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"use-four-release-gates-before-approving-the-change\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Verwenden Sie vier Freigabetore, bevor Sie die \u00c4nderung genehmigen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000071 elementor-widget elementor-widget-text-editor\" data-id=\"rt000071\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Folgende ist ein vorgeschlagener Beschaffungsablauf, kein von der EPA vorgeschriebenes Zertifizierungsverfahren. Es gibt dem OEM eine M\u00f6glichkeit, eine ungel\u00f6ste Frage zwischen Engineering, Einkauf und Produktion nicht verschwinden zu lassen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000095 e-con-full e-flex e-con e-parent\" data-id=\"rt000095\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000078 e-con-full elementor-hidden-mobile e-flex e-con e-parent\" data-id=\"rt000078\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000073 e-con-full e-flex e-con e-parent\" data-id=\"rt000073\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000072 elementor-widget elementor-widget-text-editor\" data-id=\"rt000072\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Freigabeschritt<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000075 e-con-full e-flex e-con e-parent\" data-id=\"rt000075\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000074 elementor-widget elementor-widget-text-editor\" data-id=\"rt000074\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Aufzeichnung erforderlich<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000077 e-con-full e-flex e-con e-parent\" data-id=\"rt000077\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000076 elementor-widget elementor-widget-text-editor\" data-id=\"rt000076\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Entscheidung vor dem Fortfahren<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00007f e-con-full e-flex e-con e-parent\" data-id=\"rt00007f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00007a e-con-full e-flex e-con e-parent\" data-id=\"rt00007a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000079 elementor-widget elementor-widget-text-editor\" data-id=\"rt000079\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Freigabet\u00fcr:<\/strong> Ausr\u00fcstungsklassifizierung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00007c e-con-full e-flex e-con e-parent\" data-id=\"rt00007c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007b elementor-widget elementor-widget-text-editor\" data-id=\"rt00007b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Aufzeichnung erforderlich:<\/strong> Architektur, Eisherstellungsverfahren, Erntekategorie und Zielmarkt<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00007e e-con-full e-flex e-con e-parent\" data-id=\"rt00007e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007d elementor-widget elementor-widget-text-editor\" data-id=\"rt00007d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Entscheidung vor dem Fortfahren:<\/strong> Das Team hat die anwendbare Einschr\u00e4nkung und das Compliance-Ereignis identifiziert<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000086 e-con-full e-flex e-con e-parent\" data-id=\"rt000086\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000081 e-con-full e-flex e-con e-parent\" data-id=\"rt000081\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000080 elementor-widget elementor-widget-text-editor\" data-id=\"rt000080\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Freigabet\u00fcr:<\/strong> Konstruktionsgrundlage<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000083 e-con-full e-flex e-con e-parent\" data-id=\"rt000083\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000082 elementor-widget elementor-widget-text-editor\" data-id=\"rt000082\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Aufzeichnung erforderlich:<\/strong> K\u00e4ltemittelwahl, Betriebsbereich und vorgeschlagene Konstruktions\u00e4nderung<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000085 e-con-full e-flex e-con e-parent\" data-id=\"rt000085\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000084 elementor-widget elementor-widget-text-editor\" data-id=\"rt000084\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Entscheidung vor dem Fortfahren:<\/strong> Der Lieferant bietet ein definiertes technisches Anforderungsprofil an<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00008d e-con-full e-flex e-con e-parent\" data-id=\"rt00008d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000088 e-con-full e-flex e-con e-parent\" data-id=\"rt000088\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000087 elementor-widget elementor-widget-text-editor\" data-id=\"rt000087\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Freigabet\u00fcr:<\/strong> Probenannahme<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00008a e-con-full e-flex e-con e-parent\" data-id=\"rt00008a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000089 elementor-widget elementor-widget-text-editor\" data-id=\"rt000089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Aufzeichnung erforderlich:<\/strong> Vereinbarter Inspektionsplan, relevante Komponentenbelege und Maschinenvalidierungsergebnisse<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00008c e-con-full e-flex e-con e-parent\" data-id=\"rt00008c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008b elementor-widget elementor-widget-text-editor\" data-id=\"rt00008b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Entscheidung vor dem Fortfahren:<\/strong> Die verantwortlichen Pr\u00fcfer akzeptieren die getestete Konfiguration<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000094 e-con-full e-flex e-con e-parent\" data-id=\"rt000094\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00008f e-con-full e-flex e-con e-parent\" data-id=\"rt00008f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008e elementor-widget elementor-widget-text-editor\" data-id=\"rt00008e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Freigabet\u00fcr:<\/strong> Produktionsfreigabe<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000091 e-con-full e-flex e-con e-parent\" data-id=\"rt000091\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000090 elementor-widget elementor-widget-text-editor\" data-id=\"rt000090\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Aufzeichnung erforderlich:<\/strong> Genehmigte Zeichnung, St\u00fcckliste, \u00c4nderungsprotokoll und Auftragsreferenz<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000093 e-con-full e-flex e-con e-parent\" data-id=\"rt000093\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000092 elementor-widget elementor-widget-text-editor\" data-id=\"rt000092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Entscheidung vor dem Fortfahren:<\/strong> Einkauf und Produktion verwenden die gleiche freigegebene Revision<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000096 elementor-widget elementor-widget-image\" data-id=\"rt000096\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation.webp\" class=\"attachment-full size-full wp-image-7449\" alt=\"Domi K\u00fchlschrank Spulenpr\u00fcfger\u00e4te und Maschinenvalidierungsger\u00e4te in einem professionellen Laborumfeld.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-validation-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000097 elementor-widget elementor-widget-text-editor\" data-id=\"rt000097\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>Validierungsabbildung: Komponentenpr\u00fcfungen und Validierung der Gesammaschine ben\u00f6tigen separat definierte Umfang.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000098 elementor-widget elementor-widget-text-editor\" data-id=\"rt000098\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn eine T\u00fcr offen bleibt, nennen Sie die fehlenden Belege und deren Eigent\u00fcmer. Eine Anfrage f\u00fcr eine \u00fcberarbeitete Probe kann spezifisch sein: Best\u00e4tigen Sie die Anschlussorientierung gegen\u00fcber Revision B, berichten Sie das \u00fcberarbeitete Schaltkreisvolumen oder wiederholen Sie die vereinbarten Betriebsbedingungen. Das ist umsetzbarer als eine allgemeine Zusicherung, dass eine Spule f\u00fcr R-290 geeignet ist.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000099 elementor-widget elementor-widget-text-editor\" data-id=\"rt000099\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Behalten Sie die akzeptierte Probenidentit\u00e4t mit der freigegebenen Zeichnung bei. Sp\u00e4tere \u00c4nderungen an einem Header, einer Verbindung, Beschichtung oder Rohrleitung sollten den dokumentierten \u00c4nderungsprozess durchlaufen. Dies macht eine zuk\u00fcnftige Diskrepanz nachverfolgbar auf eine Revision anstatt auf ein Produktfoto oder eine informelle Nachricht.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000c1 e-con-full e-flex e-con e-parent\" data-id=\"rt0000c1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009a elementor-widget elementor-widget-heading\" data-id=\"rt00009a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-belongs-in-an-ice-machine-coil-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was geh\u00f6rt in eine Angebotsanfrage f\u00fcr die Spule einer Eismaschine?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009b elementor-widget elementor-widget-text-editor\" data-id=\"rt00009b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beschreiben Sie die Komponente und teilen Sie dem Lieferanten mit, was er entscheiden soll. Stellen Sie das Angebotsanfrage-Paket um diese Eingaben zusammen:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009c elementor-widget elementor-widget-text-editor\" data-id=\"rt00009c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Zielmarkt, Ger\u00e4tearchitektur und Eisherstellungsverfahren.<\/li>\n<li>Angestrebtes K\u00e4ltemittel und die relevanten Ger\u00e4te- oder Listungsbedingungen, die vom OEM bereitgestellt werden.<\/li>\n<li>Kapazit\u00e4tsziel und die Betriebsbedingungen, die zu seiner Definition verwendet werden.<\/li>\n<li>Spulenskizze, Abmessungen, Befestigungspunkte, Anschl\u00fcsse und Revisionshistorie.<\/li>\n<li>Materialien, Anforderungen an den K\u00e4ltemittelkreislauf und jegliche interne Volumenbegrenzung.<\/li>\n<li>Gefrier-, Ernte- oder Dauerbetriebsanforderungen, soweit zutreffend.<\/li>\n<li>Inspektionsdokumente und angeforderte Stichprobentests mit Akzeptanzkriterien und verantwortlichen Pr\u00fcfern.<\/li>\n<li>Prototypenmenge, Produktionsprognose, Verpackungsanforderungen und gew\u00fcnschter Zeitplan.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009d elementor-widget elementor-widget-image\" data-id=\"rt00009d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq.webp\" class=\"attachment-full size-full wp-image-7450\" alt=\"Domi K\u00fchlschrank Ger\u00e4teschaltpl\u00e4ne und Komponentenhandbuch auf einer Holzwerkbank.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/ice-machine-refrigerant-rules-2026-rfq-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009e elementor-widget elementor-widget-text-editor\" data-id=\"rt00009e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>RFQ-Abbildung: Zeichnung, K\u00e4ltemittel, Einsatzbereich und Revisionsinformationen sollten die gleiche vorgeschlagene Konfiguration beschreiben.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009f elementor-widget elementor-widget-text-editor\" data-id=\"rt00009f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Unbekannte Punkte ausdr\u00fccklich auflisten. Falls die zul\u00e4ssige Ladung oder der Zertifizierungsumfang ungekl\u00e4rt ist, identifizieren Sie, wer dies kl\u00e4ren wird und wann der Lieferant mit der best\u00e4tigten Eingabe rechnen kann. Bitten Sie den Lieferanten, Annahmen mit seinem Vorschlag zur\u00fcckzugeben. Dies verhindert, dass eine vorl\u00e4ufige Angebotserstellung mit einem freigegebenen Produktionsdesign verwechselt wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000c2 e-con-full e-flex e-con e-parent\" data-id=\"rt0000c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a0 elementor-widget elementor-widget-heading\" data-id=\"rt0000a0\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">H\u00e4ufig gestellte Fragen<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a1 elementor-widget elementor-widget-heading\" data-id=\"rt0000a1\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-epa-require-all-ice-machines-to-use-r-290-in-2026\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Erfordert die EPA im Jahr 2026, dass alle Eismaschinen R-290 verwenden?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a2 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Die Regeln unterscheiden Ger\u00e4tekategorien und beschr\u00e4nken K\u00e4ltemittel nach GWP oder benannten Substanzen. Die Auswahl von R-290 muss auch die geltenden Endanwendungen und Sicherheitsbedingungen erf\u00fcllen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a3 elementor-widget elementor-widget-heading\" data-id=\"rt0000a3\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-the-1-000-lb-day-threshold-apply-to-continuous-machines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gilt die Schwelle von 1.000 lb\/Tag auch f\u00fcr Dauerbetriebmaschinen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a4 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die kleinere, eigenst\u00e4ndige Dauerbetriebskategorie verwendet eine Schwelle von 1.200 lb\/Tag. Best\u00e4tigen Sie zun\u00e4chst die Produktionsmethode und Architektur der Maschine; die t\u00e4gliche Ausgabe allein bestimmt nicht ihre Kategorie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a5 elementor-widget elementor-widget-heading\" data-id=\"rt0000a5\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-a-remote-ice-machine-covered-by-the-same-2026-event\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ist eine entfernte Eismaschine vom gleichen Ereignis im Jahr 2026 betroffen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a6 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Fernsysteme haben eine separate Installationsbeschr\u00e4nkung und ein Konformit\u00e4tsdatum zum 1. Januar 2027 in der aktuellen Sektortabelle der EPA. Wenden Sie das Ereignis der Eigenfertigung\/Import nur auf eine vor Ort montierte Anlage an.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a7 elementor-widget elementor-widget-heading\" data-id=\"rt0000a7\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-an-existing-hfc-machine-simply-be-recharged-with-propane\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kann eine bestehende HFC-Maschine einfach mit Propan nachgef\u00fcllt werden?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a8 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Eine \u00dcbergangsregel f\u00fcr neue Ger\u00e4teausr\u00fcstung erlaubt keine Umwandlung. Das K\u00e4ltemittel, die Ger\u00e4tebauweise, die Einsatzbedingungen und die geltenden Zulassungen erfordern eine spezifische \u00dcberpr\u00fcfung vor jeder \u00c4nderung.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a9 elementor-widget elementor-widget-heading\" data-id=\"rt0000a9\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-there-one-r-290-charge-limit-for-every-ice-machine\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gibt es eine R-290-Ladungsgrenze f\u00fcr jede Eismaschine?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000aa elementor-widget elementor-widget-text-editor\" data-id=\"rt0000aa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenden Sie nicht eine Ladungszahl auf jedes Modell an. Verwenden Sie die genauen Endverbrauchsbedingungen, den anwendbaren Standard und die Ger\u00e4teauflistung. Ein kleines Rohrvolumen stellt nicht die zul\u00e4ssige Gesamtmaschinenladung dar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000ab elementor-widget elementor-widget-heading\" data-id=\"rt0000ab\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-a-new-condenser-drawing-mean-the-whole-machine-is-approved\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bedeutet eine neue Kondensatorzeichnung, dass die ganze Maschine genehmigt ist?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000ac elementor-widget elementor-widget-text-editor\" data-id=\"rt0000ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nein. Die Zeichnung definiert die Komponentenrevision. Die Bewertung der vollst\u00e4ndigen Maschine umfasst auch die relevanten Betriebs-, Sicherheits- und Konstruktionsanforderungen, wobei der Umfang von den verantwortlichen Pr\u00fcfern festgelegt wird.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000ad elementor-widget elementor-widget-heading\" data-id=\"rt0000ad\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"should-every-new-supplier-repeat-the-same-tests\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sollte jeder neue Lieferant die gleichen Tests wiederholen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000ae elementor-widget elementor-widget-text-editor\" data-id=\"rt0000ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Definieren Sie die Nachweise, die f\u00fcr den tats\u00e4chlichen Lieferantenwechsel erforderlich sind. Bewahren Sie eine gemeinsame Akzeptanzbasis, dokumentieren Sie bestehende Nachweise, die weiterhin zutreffend sind, und ermitteln Sie den Pr\u00fcfungsumfang f\u00fcr die vorgeschlagene Konstruktion.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000af elementor-widget elementor-widget-heading\" data-id=\"rt0000af\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-can-domi-review-from-an-ice-machine-coil-drawing\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Was kann Domi aus einer K\u00e4ltemaschinen-Spulenzeichnung \u00fcberpr\u00fcfen?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b0 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Beginnen Sie mit der Komponenten-Geometrie, den Anschl\u00fcssen, Materialien, Schalt- und Betriebsanforderungen, die im Domi\u2019s kundenspezifischen Fertigungsservice beschrieben sind. Best\u00e4tigen Sie den Projektumfang, die Musteranforderungen und die angeforderten Dokumente mit dem Team. Ger\u00e4tezertifizierung und K\u00e4ltemittelzulassung bleiben separate Verantwortlichkeiten.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000c3 e-con-full e-flex e-con e-parent\" data-id=\"rt0000c3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b1 elementor-widget elementor-widget-heading\" data-id=\"rt0000b1\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"prepare-the-coil-specification-before-requesting-samples\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bereiten Sie die Spulen-Spezifikation vor, bevor Sie Muster anfordern<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b2 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Senden Sie die Maschinenklassifizierung und die vorgeschlagene Komponenten\u00e4nderung mit Ihrer Lieferantenanfrage. Verwenden Sie Domi\u2019s <a href=\"https:\/\/domirefrigeration.com\/de\/individuelle-registerfertigung\/\"><u>kundenspezifische W\u00e4rmetauscherfertigung<\/u><\/a> um eine zeichnungsbasierte Komponenten\u00fcberpr\u00fcfung anzufordern. F\u00fcgen Sie das beabsichtigte K\u00e4ltemittel, den Betriebsbereich und die Revisionsinformationen bei, und fragen Sie, welche Eingaben das Team noch f\u00fcr ein Angebot oder einen Musterentwurf ben\u00f6tigt.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b3 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn Tests Teil der Anfrage sind, geben Sie das Dokument und die Akzeptanzanforderung an, anstatt anzunehmen, dass sie aus einer Produktbeschreibung folgen. \u00dcberpr\u00fcfen Sie die verf\u00fcgbaren <a href=\"https:\/\/domirefrigeration.com\/de\/pruflabor\/\"><u>Testlaborinformationen<\/u><\/a> mit dem Team und best\u00e4tigen Sie den projektspezifischen Umfang, bevor Sie die Bestellung aufgeben.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b4 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"rt0000b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/de\/kontakt\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Senden Sie Ihre K\u00e4ltemaschinen-Spulenzeichnung zur \u00dcberpr\u00fcfung<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000c4 e-con-full e-flex e-con e-parent\" data-id=\"rt0000c4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b5 elementor-widget elementor-widget-heading\" data-id=\"rt0000b5\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-refrigeration-resources\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Weitere Informationen zur K\u00e4ltetechnik<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b6 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/eismaschinen-verdampferspule\/\"><u>Design des Verdampfers der Eismaschine und Eingaben f\u00fcr das Angebot<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/auswahl-des-kondensatorspulen-fur-eismaschinen\/\"><u>Auswahl des Kondensators der Eismaschine und Lasten im Kreislauf<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/naturliche-kaltemittel-gewerbliche-kuhlung\/\"><u>Nat\u00fcrliche K\u00e4ltemittel f\u00fcr die gewerbliche K\u00fchlung<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/refrigerant-types-guide\/\"><u>K\u00e4ltemittelarten und kommerzielle Anwendungen<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/individuelle-registerfertigung\/\"><u>Individuelle Spulenfertigung<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/de\/pruflabor\/\"><u>Informationen zum Spulen-Testen<\/u><\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Eine praktische \u00dcbersicht \u00fcber EPA-Kategorien f\u00fcr K\u00e4ltemittel in Eismaschinen, Einsatzbedingungen f\u00fcr R-290 sowie die Zeichnungen, Betriebsdaten und Validierungsaufzeichnungen, die ein OEM vor einer Spulenaustausch anfordern sollte.<\/p>","protected":false},"author":1,"featured_media":7440,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[54],"tags":[],"class_list":["post-7451","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oem-buyer-guides"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7451","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/comments?post=7451"}],"version-history":[{"count":3,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7451\/revisions"}],"predecessor-version":[{"id":7454,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/posts\/7451\/revisions\/7454"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media\/7440"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/media?parent=7451"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/categories?post=7451"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/de\/wp-json\/wp\/v2\/tags?post=7451"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}