{"id":7070,"date":"2026-09-27T17:10:53","date_gmt":"2026-09-27T09:10:53","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7070"},"modified":"2026-09-27T17:10:53","modified_gmt":"2026-09-27T09:10:53","slug":"guia-de-valvula-de-expansion-termostatica","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/es\/thermostatic-expansion-valve-guide\/","title":{"rendered":"Gu\u00eda de la V\u00e1lvula de Expansi\u00f3n Termost\u00e1tica: Principio de funcionamiento, sobrecalentamiento, selecci\u00f3n y entradas para solicitud de presupuesto"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7070\" class=\"elementor elementor-7070\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00006b e-con-full e-flex e-con e-parent\" data-id=\"h00006b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000001 elementor-widget elementor-widget-image\" data-id=\"h000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero.webp\" class=\"attachment-full size-full wp-image-7059\" alt=\"Sistema de refrigeraci\u00f3n industrial con compresor y serpent\u00edn de enfriamiento en un entorno comercial.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: V\u00e1lvula de expansi\u00f3n termost\u00e1tica instalada en un circuito de refrigeraci\u00f3n comercial con evaporador, bulbo sensor, igualador y l\u00ednea de l\u00edquido.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000002 elementor-widget elementor-widget-text-editor\" data-id=\"h000002\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Una v\u00e1lvula de expansi\u00f3n termost\u00e1tica (TXV) dosifica el refrigerante l\u00edquido en un evaporador de expansi\u00f3n directa respondiendo al recalentamiento en la salida del evaporador.<\/strong> La v\u00e1lvula equilibra la presi\u00f3n del bulbo sensor, la presi\u00f3n del evaporador y la fuerza del muelle para que el evaporador reciba suficiente refrigerante seg\u00fan la carga actual, mientras que el vapor sale por la salida antes de llegar al compresor. Una correcta selecci\u00f3n de la TXV requiere m\u00e1s que el tama\u00f1o de la tuber\u00eda: confirme el refrigerante, la capacidad, la temperatura de evaporaci\u00f3n, la condici\u00f3n de condensaci\u00f3n, la ca\u00edda de presi\u00f3n, el m\u00e9todo de igualaci\u00f3n, la disposici\u00f3n del distribuidor, la carga del bulbo, el tipo de conexi\u00f3n y el objetivo de recalentamiento en la puesta en marcha.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000003 elementor-widget elementor-widget-text-editor\" data-id=\"h000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Esta gu\u00eda est\u00e1 escrita para ingenieros de refrigeraci\u00f3n, compradores OEM, contratistas, distribuidores y equipos de proyectos que comparan una v\u00e1lvula nueva o un reemplazo. Separa el principio de funcionamiento de las decisiones de selecci\u00f3n e instalaci\u00f3n que determinan si la v\u00e1lvula controlar\u00e1 de manera estable en el sistema terminado.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000004 elementor-widget elementor-widget-heading\" data-id=\"h000004\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-a-thermostatic-expansion-valve-does\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu\u00e9 hace una v\u00e1lvula de expansi\u00f3n termost\u00e1tica<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000005 elementor-widget elementor-widget-text-editor\" data-id=\"h000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una TXV es un dispositivo de estrangulaci\u00f3n y dosificaci\u00f3n entre la l\u00ednea de l\u00edquido y el evaporador. Crea una ca\u00edda de presi\u00f3n, reduce la temperatura de saturaci\u00f3n del refrigerante y regula el flujo m\u00e1sico hacia el evaporador. La v\u00e1lvula reacciona a la condici\u00f3n en la salida del evaporador en lugar de abrirse simplemente por un porcentaje fijo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000006 elementor-widget elementor-widget-text-editor\" data-id=\"h000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvulas de expansi\u00f3n termost\u00e1tica 1\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Pregunta del comprador<\/th>\n<th>Respuesta pr\u00e1ctica sobre la TXV<\/th>\n<th>Por qu\u00e9 es importante en una solicitud de oferta<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u00bfQu\u00e9 controla?<\/td>\n<td>El flujo m\u00e1sico de refrigerante hacia un evaporador de expansi\u00f3n directa<\/td>\n<td>La v\u00e1lvula debe coincidir con la carga, el refrigerante y las temperaturas de funcionamiento<\/td>\n<\/tr>\n<tr>\n<td>\u00bfQu\u00e9 se\u00f1al utiliza?<\/td>\n<td>Temperatura de salida y presi\u00f3n del evaporador, expresadas como recalentamiento<\/td>\n<td>La ubicaci\u00f3n del bulbo sensor y del igualador debe estar definida<\/td>\n<\/tr>\n<tr>\n<td>\u00bfContra qu\u00e9 protege?<\/td>\n<td>Contra el retorno de l\u00edquido cuando se aplica y ajusta correctamente<\/td>\n<td>Un mal contacto del bulbo, una carga incorrecta o una sobrealimentaci\u00f3n a\u00fan pueden da\u00f1ar un compresor<\/td>\n<\/tr>\n<tr>\n<td>\u00bfEs fija o modulante?<\/td>\n<td>Modula la apertura a medida que cambian la carga y el recalentamiento<\/td>\n<td>Se necesitan datos de capacidad y ca\u00edda de presi\u00f3n para un control estable<\/td>\n<\/tr>\n<tr>\n<td>\u00bfD\u00f3nde est\u00e1 instalado?<\/td>\n<td>En la alimentaci\u00f3n de l\u00edquido cerca de la entrada del evaporador<\/td>\n<td>La disposici\u00f3n del distribuidor y el acceso para el servicio afectan la instalaci\u00f3n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000007 elementor-widget elementor-widget-text-editor\" data-id=\"h000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La palabra \u201ctermost\u00e1tico\u201d se refiere al elemento sensible a la temperatura, no a un termostato de ambiente. Una v\u00e1lvula de expansi\u00f3n termost\u00e1tica (VET) no regula directamente la temperatura de la sala, la secuencia de compresores ni el tiempo de desescarche. Esas funciones pertenecen al sistema de control de refrigeraci\u00f3n m\u00e1s amplio. Para ese l\u00edmite, consulte el <a href=\"https:\/\/domirefrigeration.com\/es\/guia-de-controles-de-refrigeracion\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">gu\u00eda de controles de refrigeraci\u00f3n<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000008 elementor-widget elementor-widget-heading\" data-id=\"h000008\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-a-thermostatic-expansion-valve-works\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">C\u00f3mo funciona una v\u00e1lvula de expansi\u00f3n termost\u00e1tica<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000009 elementor-widget elementor-widget-image\" data-id=\"h000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance.webp\" class=\"attachment-full size-full wp-image-7058\" alt=\"Vista de secci\u00f3n de una v\u00e1lvula de refrigeraci\u00f3n que muestra los componentes internos y las rutas de flujo.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Corte transversal de una v\u00e1lvula de expansi\u00f3n termost\u00e1tica que muestra el diafragma, el elemento de potencia, el resorte, el orificio y el recorrido del refrigerante.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000a elementor-widget elementor-widget-text-editor\" data-id=\"h00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La v\u00e1lvula tiene un elemento de potencia, bulbo sensor, tubo capilar, diafragma, resorte, asiento de v\u00e1lvula, orificio y un paso o conexi\u00f3n igualizadora. En condiciones estables, tres fuerzas principales se equilibran:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000b elementor-widget elementor-widget-text-editor\" data-id=\"h00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvulas de expansi\u00f3n termost\u00e1tica 2\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Fuerza<\/th>\n<th>Fuente<\/th>\n<th>Direcci\u00f3n sobre el diafragma<\/th>\n<th>Efecto operativo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Presi\u00f3n del bulbo<\/td>\n<td>El fluido en el bulbo sensor responde a la temperatura de la l\u00ednea de aspiraci\u00f3n<\/td>\n<td>Abre la v\u00e1lvula<\/td>\n<td>Una temperatura detectada m\u00e1s alta generalmente aumenta la fuerza de apertura<\/td>\n<\/tr>\n<tr>\n<td>Presi\u00f3n del evaporador<\/td>\n<td>Presi\u00f3n transmitida a trav\u00e9s de un igualizador interno o externo<\/td>\n<td>Cierra la v\u00e1lvula<\/td>\n<td>Cambia con la presi\u00f3n de evaporaci\u00f3n y la ca\u00edda de presi\u00f3n a trav\u00e9s del evaporador<\/td>\n<\/tr>\n<tr>\n<td>Presi\u00f3n del resorte<\/td>\n<td>Resorte de ajuste de sobrecalentamiento<\/td>\n<td>Cierra la v\u00e1lvula<\/td>\n<td>Establece la parte est\u00e1tica de la configuraci\u00f3n de sobrecalentamiento<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000c elementor-widget elementor-widget-text-editor\" data-id=\"h00000c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El equilibrio simplificado es <strong>presi\u00f3n del bulbo = presi\u00f3n del evaporador + fuerza del resorte<\/strong>. Cuando la carga aumenta, la salida del evaporador tiende a calentarse y la presi\u00f3n del bulbo sube. El diafragma se mueve hacia la apertura, admitiendo m\u00e1s l\u00edquido. Cuando la salida se enfr\u00eda y el sobrecalentamiento disminuye, las fuerzas de cierre recuperan el equilibrio y la v\u00e1lvula reduce el flujo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000d elementor-widget elementor-widget-text-editor\" data-id=\"h00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Esta respuesta es la raz\u00f3n por la que una v\u00e1lvula TXV puede seguir los cambios de carga m\u00e1s eficazmente que un restrictor fijo. No significa que la v\u00e1lvula pueda corregir todos los problemas del sistema. Una l\u00ednea de l\u00edquido insuficiente, un filtro-secador bloqueado, subenfriamiento inadecuado, carga de refrigerante incorrecta, flujo de aire deficiente o un bulbo mal instalado pueden parecer problemas de dosificaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000e elementor-widget elementor-widget-text-editor\" data-id=\"h00000e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El <a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/R26\/SI\/r26_ch11\/r26_ch11_si.aspx\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Cap\u00edtulo de dispositivos de control de refrigeraci\u00f3n de ASHRAE<\/a> describe el mismo equilibrio de presiones y distingue entre sobrecalentamiento est\u00e1tico, de apertura y operativo. El <a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/how-thermostatic-expansion-valves-work\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Explicaci\u00f3n de TXV Danfoss<\/a> tambi\u00e9n es \u00fatil para formar equipos de instalaci\u00f3n y servicio.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000f elementor-widget elementor-widget-heading\" data-id=\"h00000f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"superheat-the-control-variable-buyers-must-define\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sobrecalentamiento: la variable de control que los compradores deben definir<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000010 elementor-widget elementor-widget-image\" data-id=\"h000010\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement.webp\" class=\"attachment-full size-full wp-image-7057\" alt=\"T\u00e9cnico inspeccionando un sistema de refrigeraci\u00f3n industrial con man\u00f3metros y herramientas.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: t\u00e9cnico de refrigeraci\u00f3n asi\u00e1tico midiendo la presi\u00f3n de succi\u00f3n y la temperatura de salida para calcular el sobrecalentamiento del evaporador.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000011 elementor-widget elementor-widget-text-editor\" data-id=\"h000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El sobrecalentamiento es la diferencia entre la temperatura real del vapor en un punto de medici\u00f3n y la temperatura de saturaci\u00f3n del refrigerante correspondiente a la presi\u00f3n medida en ese punto. En un sistema TXV, los t\u00e9cnicos normalmente eval\u00faan el sobrecalentamiento en la salida del evaporador o el sobrecalentamiento total de succi\u00f3n seg\u00fan el dise\u00f1o del equipo y el procedimiento del fabricante.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000012 elementor-widget elementor-widget-text-editor\" data-id=\"h000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvulas de expansi\u00f3n termost\u00e1tica 3\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>T\u00e9rmino<\/th>\n<th>Significado<\/th>\n<th>Uso durante la selecci\u00f3n o puesta en marcha<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Sobrecalentamiento est\u00e1tico<\/td>\n<td>Sobrecalentamiento en el que la v\u00e1lvula comienza a abrirse<\/td>\n<td>Parte del ajuste de f\u00e1brica y selecci\u00f3n del resorte<\/td>\n<\/tr>\n<tr>\n<td>Sobrecalentamiento de apertura<\/td>\n<td>Sobrecalentamiento adicional necesario para abrir la v\u00e1lvula a una posici\u00f3n \u00fatil<\/td>\n<td>Utilizado en las clasificaciones de capacidad del fabricante<\/td>\n<\/tr>\n<tr>\n<td>Sobrecalentamiento operativo<\/td>\n<td>Sobrecalentamiento est\u00e1tico m\u00e1s de apertura bajo la carga de trabajo<\/td>\n<td>El valor de campo utilizado para evaluar el riesgo de alimentaci\u00f3n y retorno de l\u00edquido<\/td>\n<\/tr>\n<tr>\n<td>Sobrecalentamiento en la salida del evaporador<\/td>\n<td>Aumento de temperatura por encima de la saturaci\u00f3n en la salida del evaporador<\/td>\n<td>Ayuda a confirmar que el evaporador est\u00e1 alimentado sin retornar l\u00edquido<\/td>\n<\/tr>\n<tr>\n<td>Sobrecalentamiento total de aspiraci\u00f3n<\/td>\n<td>Sobrecalentamiento en la salida m\u00e1s calor absorbido en la l\u00ednea de aspiraci\u00f3n<\/td>\n<td>\u00datil para la protecci\u00f3n de la entrada del compresor, pero no debe confundirse con el sobrecalentamiento en la salida del evaporador<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000013 elementor-widget elementor-widget-text-editor\" data-id=\"h000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El objetivo exacto depende del refrigerante, dise\u00f1o del evaporador, carga, distribuidor, requisitos del compresor y las instrucciones del fabricante del equipo. Evite poner un n\u00famero universal en una solicitud de oferta cuando las condiciones del sistema no se conocen. Una v\u00e1lvula seleccionada por \u201ccapacidad m\u00e1xima de reserva\u201d puede funcionar con un sobrecalentamiento indeseable y modular mal a baja carga.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000014 elementor-widget elementor-widget-heading\" data-id=\"h000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"sensing-bulb-and-equalizer-arrangement\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Disposici\u00f3n del bulbo sensor y del igualador<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000015 elementor-widget elementor-widget-image\" data-id=\"h000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation.webp\" class=\"attachment-full size-full wp-image-7060\" alt=\"Primer plano de tuber\u00edas de cobre de refrigeraci\u00f3n y aislamiento en un sistema de refrigeraci\u00f3n comercial.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Bulbo sensor de v\u00e1lvula de expansi\u00f3n termost\u00e1tica fijado a una l\u00ednea de aspiraci\u00f3n horizontal limpia con aislamiento y un igualador externo.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000016 elementor-widget elementor-widget-text-editor\" data-id=\"h000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El bulbo sensor es la entrada de temperatura de la v\u00e1lvula. Normalmente se coloca en la l\u00ednea de aspiraci\u00f3n a la salida del evaporador, donde puede detectar una temperatura representativa del vapor. La l\u00ednea debe estar limpia, el bulbo debe tener contacto t\u00e9rmico firme y la abrazadera debe adaptarse al tama\u00f1o del tubo. Puede ser necesario el aislamiento cuando el aire circundante pueda distorsionar la lectura.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000017 elementor-widget elementor-widget-text-editor\" data-id=\"h000017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La ubicaci\u00f3n del bulbo es parte del dise\u00f1o de control. Si est\u00e1 demasiado cerca de una fuente de calor, colocado donde se puede acumular l\u00edquido, montado en una secci\u00f3n poco representativa o suelto, la v\u00e1lvula de expansi\u00f3n termost\u00e1tica puede oscilar, alimentar poco o alimentar en exceso. El instalador debe seguir la orientaci\u00f3n y posici\u00f3n del bulbo permitidas por el fabricante de la v\u00e1lvula para el di\u00e1metro real de la tuber\u00eda y el refrigerante.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000018 elementor-widget elementor-widget-image\" data-id=\"h000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer.webp\" class=\"attachment-full size-full wp-image-7061\" alt=\"Trayectorias de igualador interno y externo en un circuito de v\u00e1lvula de expansi\u00f3n termost\u00e1tica con un evaporador de m\u00faltiples circuitos\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Caminos de igualador interno y externo en un circuito de v\u00e1lvula de expansi\u00f3n termost\u00e1tica con un evaporador multicircuito.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000019 elementor-widget elementor-widget-text-editor\" data-id=\"h000019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La igualaci\u00f3n interna toma la presi\u00f3n del evaporador a trav\u00e9s de un conducto en el cuerpo de la v\u00e1lvula. La igualaci\u00f3n externa utiliza una l\u00ednea separada conectada a la salida del evaporador u otro punto de presi\u00f3n especificado. La igualaci\u00f3n externa suele ser necesaria cuando el evaporador, el distribuidor o el camino de aspiraci\u00f3n generan una ca\u00edda de presi\u00f3n significativa. La selecci\u00f3n debe confirmarse seg\u00fan el dise\u00f1o del circuito del evaporador en lugar de inferirse por el tama\u00f1o de la conexi\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001a elementor-widget elementor-widget-text-editor\" data-id=\"h00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvulas de expansi\u00f3n termost\u00e1tica 4\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Disposici\u00f3n<\/th>\n<th>Punto de partida apropiado<\/th>\n<th>Preguntas para confirmar<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Igualador interno<\/td>\n<td>Evaporador compacto de un solo circuito con ca\u00edda de presi\u00f3n interna limitada<\/td>\n<td>\u00bfLa presi\u00f3n en la salida de la v\u00e1lvula es representativa de la salida del evaporador?<\/td>\n<\/tr>\n<tr>\n<td>Igualador externo<\/td>\n<td>Evaporador multicircuito, distribuidor o mayor ca\u00edda de presi\u00f3n<\/td>\n<td>\u00bfD\u00f3nde debe conectarse el igualador y se incluye un punto de toma de presi\u00f3n o accesorio?<\/td>\n<\/tr>\n<tr>\n<td>Igualador externo con distribuidor<\/td>\n<td>Sistemas donde la p\u00e9rdida de presi\u00f3n en la distribuci\u00f3n afecta el punto de control<\/td>\n<td>\u00bfLa capacidad de la v\u00e1lvula seleccionada tiene en cuenta la ca\u00edda de presi\u00f3n en el distribuidor?<\/td>\n<\/tr>\n<tr>\n<td>Ubicaci\u00f3n remota o inusual del bulbo<\/td>\n<td>Equipos con rutas de aspiraci\u00f3n especiales o intercambiadores de calor<\/td>\n<td>\u00bfAprueba el fabricante el punto de detecci\u00f3n y la carga para este arreglo?<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001b elementor-widget elementor-widget-heading\" data-id=\"h00001b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"txv-types-and-when-to-compare-them\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tipos de VET y cu\u00e1ndo compararlos<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001c elementor-widget elementor-widget-image\" data-id=\"h00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types.webp\" class=\"attachment-full size-full wp-image-7062\" alt=\"Colecci\u00f3n de v\u00e1lvulas de refrigeraci\u00f3n industrial en un banco de trabajo en Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Comparaci\u00f3n de v\u00e1lvulas de expansi\u00f3n termost\u00e1tica igualadas internamente, igualadas externamente, de puerto equilibrado y de orificio reemplazable.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001d elementor-widget elementor-widget-text-editor\" data-id=\"h00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diferentes VET pueden parecer similares pero tener comportamientos de control distintos. Compare la construcci\u00f3n interna y la clasificaci\u00f3n de aplicaci\u00f3n, no solo la conexi\u00f3n de entrada y salida.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001e elementor-widget elementor-widget-text-editor\" data-id=\"h00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvulas de expansi\u00f3n termost\u00e1tica 5\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Tipo o caracter\u00edstica de VET<\/th>\n<th>Qu\u00e9 cambia<\/th>\n<th>D\u00f3nde puede ser \u00fatil<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Igualada internamente<\/td>\n<td>La presi\u00f3n del evaporador se detecta a trav\u00e9s del cuerpo de la v\u00e1lvula<\/td>\n<td>Circuitos simples con peque\u00f1a ca\u00edda de presi\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Igualada externamente<\/td>\n<td>Un igualador dedicado detecta la presi\u00f3n en el punto aguas abajo especificado<\/td>\n<td>Evaporadores multicircuito y aplicaciones con distribuidores<\/td>\n<\/tr>\n<tr>\n<td>Puerto convencional<\/td>\n<td>Las fuerzas del puerto var\u00edan seg\u00fan las condiciones de presi\u00f3n en la v\u00e1lvula<\/td>\n<td>Aplicaciones m\u00e1s peque\u00f1as o menos exigentes cuando la clasificaci\u00f3n del fabricante lo permite<\/td>\n<\/tr>\n<tr>\n<td>Puerto equilibrado<\/td>\n<td>El dise\u00f1o del puerto reduce el efecto de la variaci\u00f3n de presi\u00f3n de entrada sobre la fuerza de apertura<\/td>\n<td>Mayor capacidad o condiciones de presi\u00f3n variable cuando se especifica<\/td>\n<\/tr>\n<tr>\n<td>Carga de bulbo universal<\/td>\n<td>Respuesta operativa amplia en un rango de temperatura definido<\/td>\n<td>Aplicaciones generales dentro del rango del fabricante de la carga<\/td>\n<\/tr>\n<tr>\n<td>Carga antihunting o selectiva<\/td>\n<td>La amortiguaci\u00f3n o una respuesta presi\u00f3n-temperatura seleccionada cambia la modulaci\u00f3n<\/td>\n<td>Sistemas donde el hunting o un rango operativo estrecho es una preocupaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Orificio intercambiable<\/td>\n<td>El cuerpo y la capacidad de dosificaci\u00f3n pueden combinarse con un inserto<\/td>\n<td>Inventario de servicio y rangos de capacidad seleccionados, si est\u00e1n aprobados por el fabricante<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001f elementor-widget elementor-widget-text-editor\" data-id=\"h00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El <a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/walk-in-coolers-thermostatic-expansion-valves-and-solenoid-valves\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Explicaci\u00f3n del enfriador de c\u00e1mara frigor\u00edfica Danfoss<\/a> explica c\u00f3mo el bulbo, el diafragma, el igualador y el resorte trabajan juntos. Para un dise\u00f1o comercial o industrial reparable, tambi\u00e9n registre si el elemento de potencia, el cuerpo, el orificio y las conexiones son reemplazables como piezas separadas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000020 elementor-widget elementor-widget-heading\" data-id=\"h000020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"txv-selection-inputs-for-a-refrigeration-project\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Entradas de selecci\u00f3n de TXV para un proyecto de refrigeraci\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000021 elementor-widget elementor-widget-image\" data-id=\"h000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs.webp\" class=\"attachment-full size-full wp-image-7063\" alt=\"Ingeniero analizando datos del sistema de refrigeraci\u00f3n en las instalaciones de Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: ingeniero de HVACR asi\u00e1tico revisando refrigerante, capacidad, temperatura de evaporaci\u00f3n, ca\u00edda de presi\u00f3n y entradas de selecci\u00f3n de TXV.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000022 elementor-widget elementor-widget-text-editor\" data-id=\"h000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un fabricante o distribuidor debe poder reproducir la selecci\u00f3n a partir de la informaci\u00f3n en la solicitud de oferta. Proporcione puntos de operaci\u00f3n en lugar de solo la potencia nominal o el di\u00e1metro de la tuber\u00eda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000023 elementor-widget elementor-widget-text-editor\" data-id=\"h000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvula de expansi\u00f3n termost\u00e1tica 6\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Entrada de selecci\u00f3n<\/th>\n<th>Informaci\u00f3n m\u00ednima a proporcionar<\/th>\n<th>Por qu\u00e9 el proveedor de v\u00e1lvulas lo necesita<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Refrigerante<\/td>\n<td>Designaci\u00f3n exacta del refrigerante y estado de mezcla o adaptaci\u00f3n<\/td>\n<td>La capacidad, el comportamiento presi\u00f3n-temperatura, la carga del bulbo y los materiales dependen de ello<\/td>\n<\/tr>\n<tr>\n<td>Capacidad de refrigeraci\u00f3n<\/td>\n<td>Capacidad requerida en la condici\u00f3n de evaporaci\u00f3n de dise\u00f1o<\/td>\n<td>La v\u00e1lvula debe alimentar la carga sin depender de una capacidad de reserva no aprobada<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de evaporaci\u00f3n<\/td>\n<td>Rango de dise\u00f1o y de operaci\u00f3n esperado<\/td>\n<td>Determina la presi\u00f3n, el comportamiento de sobrecalentamiento y la clasificaci\u00f3n de la v\u00e1lvula<\/td>\n<\/tr>\n<tr>\n<td>Condici\u00f3n de condensaci\u00f3n<\/td>\n<td>Temperatura de condensaci\u00f3n de dise\u00f1o o rango de presi\u00f3n<\/td>\n<td>Afecta la ca\u00edda de presi\u00f3n disponible y la estabilidad de la alimentaci\u00f3n de l\u00edquido<\/td>\n<\/tr>\n<tr>\n<td>Temperatura del l\u00edquido y subenfriamiento<\/td>\n<td>Temperatura en la entrada de la v\u00e1lvula y subenfriamiento de l\u00edquido disponible<\/td>\n<td>Confirma que el l\u00edquido llega al dispositivo de medici\u00f3n sin gas flash<\/td>\n<\/tr>\n<tr>\n<td>Ca\u00edda de presi\u00f3n<\/td>\n<td>Ca\u00edda de presi\u00f3n disponible a trav\u00e9s de la v\u00e1lvula en el punto de dise\u00f1o<\/td>\n<td>Las tablas de capacidad est\u00e1n vinculadas a la ca\u00edda de presi\u00f3n, no solo al di\u00e1metro de conexi\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Circuito del evaporador<\/td>\n<td>Circuito simple o m\u00faltiple, tipo de distribuidor y p\u00e9rdida de presi\u00f3n<\/td>\n<td>Determina la disposici\u00f3n del igualador y la compatibilidad del distribuidor<\/td>\n<\/tr>\n<tr>\n<td>Carga del bulbo y sobrecalentamiento<\/td>\n<td>Familia de carga requerida y ajuste inicial o de f\u00e1brica<\/td>\n<td>Controla el rango de respuesta y el comportamiento a baja carga<\/td>\n<\/tr>\n<tr>\n<td>Conexiones<\/td>\n<td>Tama\u00f1o de entrada\/salida, material del tubo, conexi\u00f3n por abocardado\/soldadura o de otro tipo<\/td>\n<td>Evita que una coincidencia dimensional oculte una discrepancia de flujo o instalaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Ambiente y servicio<\/td>\n<td>Sala, proceso, reducci\u00f3n de temperatura, carga de mantenimiento y rango de modulaci\u00f3n<\/td>\n<td>Revela si la v\u00e1lvula debe modular a trav\u00e9s de un amplio rango de carga<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000024 elementor-widget elementor-widget-text-editor\" data-id=\"h000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No dimensione una v\u00e1lvula TXV solo por el desplazamiento del compresor. La v\u00e1lvula percibe la carga y las condiciones de presi\u00f3n del evaporador. Si el equipo opera en varios modos, enumere cada modo y solicite al proveedor que verifique el orificio y la capacidad seleccionados en todo el rango operativo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000025 elementor-widget elementor-widget-heading\" data-id=\"h000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"matching-txv-capacity-to-pressure-drop-and-load\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Coincidencia de la capacidad del TXV con la ca\u00edda de presi\u00f3n y la carga<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000026 elementor-widget elementor-widget-image\" data-id=\"h000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications.webp\" class=\"attachment-full size-full wp-image-7064\" alt=\"Sistema de refrigeraci\u00f3n industrial con compresores, intercambiadores de calor y tuber\u00edas.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Aplicaci\u00f3n de refrigeraci\u00f3n mostrando l\u00ednea de l\u00edquido, TXV, distribuidor, evaporador, l\u00ednea de aspiraci\u00f3n, compresor y condensador.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000027 elementor-widget elementor-widget-text-editor\" data-id=\"h000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las tablas de capacidad suelen variar seg\u00fan el refrigerante, la temperatura de evaporaci\u00f3n, la condici\u00f3n de condensaci\u00f3n o entrada y la ca\u00edda de presi\u00f3n. Una v\u00e1lvula que parece suficientemente grande en un punto de operaci\u00f3n puede ser inestable en otro. Una v\u00e1lvula demasiado peque\u00f1a puede dejar el evaporador sin suficiente refrigerante en carga m\u00e1xima; una v\u00e1lvula demasiado grande puede perder resoluci\u00f3n y oscilar en carga parcial.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000028 elementor-widget elementor-widget-text-editor\" data-id=\"h000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilice esta secuencia al comparar selecciones de cat\u00e1logo:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000029 elementor-widget elementor-widget-text-editor\" data-id=\"h000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li>Indique la capacidad de dise\u00f1o y el rango de capacidad, incluyendo reducci\u00f3n de temperatura y carga m\u00ednima de mantenimiento.<\/li>\n<li>Determine la temperatura y presi\u00f3n del l\u00edquido disponible en la entrada de la v\u00e1lvula.<\/li>\n<li>Calcule u obtenga la ca\u00edda de presi\u00f3n disponible a trav\u00e9s de la v\u00e1lvula despu\u00e9s de considerar p\u00e9rdidas en la l\u00ednea, solenoide, distribuidor y accesorios.<\/li>\n<li>Utilice la tabla de capacidad o herramienta de selecci\u00f3n del fabricante para el refrigerante exacto y la condici\u00f3n de evaporaci\u00f3n.<\/li>\n<li>Verifique la v\u00e1lvula seleccionada en los puntos de operaci\u00f3n bajos y altos, incluyendo el rango de modulaci\u00f3n.<\/li>\n<li>Confirme que la v\u00e1lvula, el orificio, la carga, el igualador y el distribuidor sean un conjunto compatible.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002a elementor-widget elementor-widget-text-editor\" data-id=\"h00002a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El <a href=\"https:\/\/virtualengineer.parker.com\/myprojects\/Sizing\/Sizing?WFID=3f133247-cf7d-f011-b481-000d3a7abe26\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Herramienta de selecci\u00f3n Virtual Engineer de Parker Sporlan<\/a> ilustra por qu\u00e9 la selecci\u00f3n requiere datos de aplicaci\u00f3n. Considere cualquier resultado de cat\u00e1logo como una selecci\u00f3n inicial hasta que el proveedor confirme el rango operativo final.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002b elementor-widget elementor-widget-heading\" data-id=\"h00002b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"refrigerant-bulb-charge-and-material-compatibility\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Refrigerante, carga del bulbo y compatibilidad de materiales<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002c elementor-widget elementor-widget-text-editor\" data-id=\"h00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El refrigerante afecta el comportamiento presi\u00f3n-temperatura, la capacidad, los materiales requeridos y la respuesta del elemento termost\u00e1tico. Una v\u00e1lvula de reemplazo debe comprobarse con el refrigerante real en el circuito, incluyendo un cambio de retrofit o mezcla. \u201cMisma conexi\u00f3n\u201d no es prueba de compatibilidad.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002d elementor-widget elementor-widget-text-editor\" data-id=\"h00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Confirme estos puntos en la documentaci\u00f3n t\u00e9cnica:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002e elementor-widget elementor-widget-text-editor\" data-id=\"h00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Designaci\u00f3n del refrigerante y si el sistema ha sido convertido desde otro refrigerante.<\/li>\n<li>Carga de bulbo aprobada o elemento de potencia para el rango de temperatura de evaporaci\u00f3n.<\/li>\n<li>Compatibilidad del cuerpo de la v\u00e1lvula, asiento, diafragma, juntas y empaquetaduras.<\/li>\n<li>Clasificaci\u00f3n de presi\u00f3n y presi\u00f3n de trabajo permitida para los lados de alta y baja.<\/li>\n<li>Condiciones de aceite y contaminaci\u00f3n, especialmente despu\u00e9s de una aver\u00eda o quemado del compresor.<\/li>\n<li>Si la v\u00e1lvula necesita un filtro-secador, colador de entrada o procedimiento de limpieza aguas arriba.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002f elementor-widget elementor-widget-text-editor\" data-id=\"h00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/50825\/AX266348279899en-000101.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Notas del instalador Danfoss<\/a> describa el equilibrio de presi\u00f3n y el papel del muelle en el ajuste del recalentamiento. Para la selecci\u00f3n final, controlan el cat\u00e1logo actual del fabricante de v\u00e1lvulas y los datos de aplicaci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000030 elementor-widget elementor-widget-heading\" data-id=\"h000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"common-txv-symptoms-and-diagnostic-order\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">S\u00edntomas comunes de la v\u00e1lvula de expansi\u00f3n termost\u00e1tica (TXV) y orden de diagn\u00f3stico<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000031 elementor-widget elementor-widget-image\" data-id=\"h000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms.webp\" class=\"attachment-full size-full wp-image-7065\" alt=\"T\u00e9cnico inspeccionando una unidad de refrigeraci\u00f3n comercial con herramientas de diagn\u00f3stico.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: T\u00e9cnico de servicio asi\u00e1tico diagnosticando un sistema de refrigeraci\u00f3n con man\u00f3metros, sondas, escarcha en el evaporador, filtro-secador y TXV.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000032 elementor-widget elementor-widget-text-editor\" data-id=\"h000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un s\u00edntoma del sistema rara vez prueba que la TXV est\u00e9 defectuosa. Utilice un orden de diagn\u00f3stico fijo para que una l\u00ednea de l\u00edquido bloqueada o una carga incorrecta no se confunda con una v\u00e1lvula defectuosa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000033 elementor-widget elementor-widget-text-editor\" data-id=\"h000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvula de expansi\u00f3n termost\u00e1tica 7\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>S\u00edntoma observado<\/th>\n<th>Posibles causas de la TXV o del sistema<\/th>\n<th>Comprobaciones antes del reemplazo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Baja capacidad del evaporador y alto recalentamiento de salida<\/td>\n<td>V\u00e1lvula estrangulada, baja presi\u00f3n de l\u00edquido, gas flash, secador bloqueado, baja carga, bulbo sin sensar<\/td>\n<td>Compruebe el subenfriamiento del l\u00edquido, el visor donde est\u00e9 instalado, la ca\u00edda de presi\u00f3n, el contacto del bulbo y el igualador<\/td>\n<\/tr>\n<tr>\n<td>Bajo recalentamiento o riesgo de retorno de l\u00edquido<\/td>\n<td>Sobrealimentaci\u00f3n, carga de bulbo incorrecta, bulbo flojo, ajuste incorrecto, baja carga, problema en el distribuidor<\/td>\n<td>Verifique el punto de medici\u00f3n, la instalaci\u00f3n del bulbo, la carga, la carga de refrigerante y la protecci\u00f3n del compresor<\/td>\n<\/tr>\n<tr>\n<td>Sobrecalentamiento oscilante<\/td>\n<td>V\u00e1lvula sobredimensionada, ca\u00edda de presi\u00f3n inestable, mala ubicaci\u00f3n del bulbo, carga incompatible, alimentaci\u00f3n de l\u00edquido intermitente<\/td>\n<td>Registre el sobrecalentamiento a lo largo del tiempo e inspeccione el estado de la entrada y los cambios de carga<\/td>\n<\/tr>\n<tr>\n<td>Escarcha en la v\u00e1lvula o en la entrada<\/td>\n<td>Ca\u00edda de presi\u00f3n y formaci\u00f3n de gas, humedad, restricci\u00f3n o condici\u00f3n anormal en el lado de baja presi\u00f3n<\/td>\n<td>Compruebe el filtro-secador, la temperatura del l\u00edquido, las lecturas de presi\u00f3n y el estado del refrigerante<\/td>\n<\/tr>\n<tr>\n<td>Sin respuesta al ajuste<\/td>\n<td>Elemento de potencia da\u00f1ado, aguja trabada, igualador bloqueado, direcci\u00f3n de ajuste incorrecta o una falla diferente en el sistema<\/td>\n<td>Siga el procedimiento del fabricante y verifique los instrumentos de presi\u00f3n y temperatura<\/td>\n<\/tr>\n<tr>\n<td>Funciona con una carga pero falla con otra<\/td>\n<td>Desajuste de capacidad, carga o ca\u00edda de presi\u00f3n en el rango de operaci\u00f3n<\/td>\n<td>Vuelva a comprobar los puntos de selecci\u00f3n de carga baja y carga m\u00e1xima<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000034 elementor-widget elementor-widget-text-editor\" data-id=\"h000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No gire el v\u00e1stago de ajuste repetidamente sin registrar la posici\u00f3n original y esperar a que el sistema se estabilice. Una lectura de presi\u00f3n-temperatura tomada en un instante puede ocultar una condici\u00f3n oscilante o intermitente. Si un compresor ha experimentado retorno de l\u00edquido o quemado, incluya comprobaciones de limpieza del aceite y del sistema en el plan de servicio.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000035 elementor-widget elementor-widget-heading\" data-id=\"h000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"installation-details-that-affect-txv-performance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Detalles de instalaci\u00f3n que afectan el rendimiento del TXV<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000036 elementor-widget elementor-widget-image\" data-id=\"h000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation.webp\" class=\"attachment-full size-full wp-image-7066\" alt=\"Sistema de refrigeraci\u00f3n industrial con tuber\u00edas de cobre y unidades de enfriamiento en Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Instalaci\u00f3n limpia de v\u00e1lvula de expansi\u00f3n termost\u00e1tica cerca de un evaporador con alimentaci\u00f3n de l\u00edquido corta, distribuidor y tuber\u00eda soportada.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000037 elementor-widget elementor-widget-text-editor\" data-id=\"h000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Siga el bolet\u00edn de instalaci\u00f3n del fabricante de la v\u00e1lvula y el plano del equipo. <a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Sporlan\/Sporlan-pdf-files\/Sporlan-pdf-010\/10-11.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Bolet\u00edn de instalaci\u00f3n de Sporlan<\/a> destaca la ubicaci\u00f3n de la v\u00e1lvula, la proximidad al distribuidor, el soporte y la correcta instalaci\u00f3n del igualador y del bulbo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000038 elementor-widget elementor-widget-text-editor\" data-id=\"h000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las comprobaciones de instalaci\u00f3n deben incluir:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000039 elementor-widget elementor-widget-text-editor\" data-id=\"h000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Monte la v\u00e1lvula lo m\u00e1s cerca posible del evaporador seg\u00fan lo permita el dise\u00f1o del circuito.<\/li>\n<li>Mantenga la l\u00ednea entre la v\u00e1lvula y el distribuidor corta y libre de codos o restricciones innecesarias.<\/li>\n<li>Proteja el cuerpo de la v\u00e1lvula y el elemento de potencia del calor excesivo de la soldadura.<\/li>\n<li>Instale el bulbo en una superficie limpia y representativa de la l\u00ednea de aspiraci\u00f3n, con la abrazadera y orientaci\u00f3n especificadas.<\/li>\n<li>Fije e aisle el bulbo donde lo requiera el fabricante o el dise\u00f1o del equipo.<\/li>\n<li>Conduzca el igualador externo al punto de presi\u00f3n especificado, sin restricciones no deseadas ni bolsas de aceite atrapadas.<\/li>\n<li>Soporte las v\u00e1lvulas y tuber\u00edas de mayor tama\u00f1o para que la vibraci\u00f3n no cargue las uniones.<\/li>\n<li>Evite que la humedad, los residuos, la escoria de soldadura y la exposici\u00f3n al aire libre entren en el circuito.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003a elementor-widget elementor-widget-text-editor\" data-id=\"h00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si se coloca una v\u00e1lvula solenoide, v\u00e1lvula manual, distribuidor, acumulador de aspiraci\u00f3n o intercambiador de calor alrededor de la VET, mu\u00e9strelo en el diagrama de tuber\u00edas e incluya su ca\u00edda de presi\u00f3n en la revisi\u00f3n de selecci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003b elementor-widget elementor-widget-heading\" data-id=\"h00003b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"commissioning-and-superheat-verification\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Puesta en marcha y verificaci\u00f3n de sobrecalentamiento<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003c elementor-widget elementor-widget-image\" data-id=\"h00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning.webp\" class=\"attachment-full size-full wp-image-7067\" alt=\"Ingeniero de puesta en marcha asi\u00e1tico registrando presi\u00f3n de succi\u00f3n, temperatura de tuber\u00eda, sobrecalentamiento y condiciones de carga en una hoja de prueba de refrigeraci\u00f3n\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: ingeniero de puesta en marcha asi\u00e1tico registrando presi\u00f3n de aspiraci\u00f3n, temperatura de tuber\u00eda, sobrecalentamiento y condiciones de carga en una hoja de prueba de refrigeraci\u00f3n.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003d elementor-widget elementor-widget-text-editor\" data-id=\"h00003d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La puesta en marcha debe establecer una base estable antes de ajustar la VET. Registre el refrigerante, la condici\u00f3n exterior o de planta, la carga de sala o proceso, las presiones de evaporador y aspiraci\u00f3n, las temperaturas relevantes, el estado de la l\u00ednea de l\u00edquido, el estado del compresor y el estado de desescarche.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003e elementor-widget elementor-widget-text-editor\" data-id=\"h00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvula de expansi\u00f3n termost\u00e1tica 8\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Paso de puesta en marcha<\/th>\n<th>Registro<\/th>\n<th>Decision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Confirme el circuito<\/td>\n<td>Refrigerante, modelo de v\u00e1lvula, orificio, carga del bulbo, igualador y orientaci\u00f3n de tuber\u00edas<\/td>\n<td>Rechace una incompatibilidad antes del ajuste<\/td>\n<\/tr>\n<tr>\n<td>Confirme la alimentaci\u00f3n de l\u00edquido<\/td>\n<td>Temperatura del l\u00edquido, subenfriamiento, presi\u00f3n en la entrada de la v\u00e1lvula y estado del filtro-secador<\/td>\n<td>Corrija primero el gas flash o la restricci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Mida la salida del evaporador<\/td>\n<td>Presi\u00f3n y temperatura en el punto de medici\u00f3n especificado<\/td>\n<td>Calcular el valor de sobrecalentamiento previsto<\/td>\n<\/tr>\n<tr>\n<td>Observar la estabilidad<\/td>\n<td>Lecturas durante el descenso de temperatura, mantenimiento y carga m\u00ednima<\/td>\n<td>Identificar caza o mala modulaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td>Comprobar la entrada del compresor<\/td>\n<td>Temperatura de aspiraci\u00f3n, presi\u00f3n y l\u00edmites del fabricante<\/td>\n<td>Confirmar que el compresor est\u00e1 protegido<\/td>\n<\/tr>\n<tr>\n<td>Ajustar solo si es necesario<\/td>\n<td>Direcci\u00f3n, cantidad, tiempo permitido para la estabilizaci\u00f3n y lecturas finales<\/td>\n<td>Conservar un ajuste final trazable<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003f elementor-widget elementor-widget-text-editor\" data-id=\"h00003f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La medici\u00f3n de sobrecalentamiento requiere una lectura de presi\u00f3n convertida con la relaci\u00f3n correcta presi\u00f3n-temperatura del refrigerante y una medici\u00f3n de temperatura en la ubicaci\u00f3n correcta de la tuber\u00eda. No compare la temperatura de la l\u00ednea de aspiraci\u00f3n a varios metros del evaporador con un objetivo de salida del evaporador sin tener en cuenta la ganancia de calor en la l\u00ednea.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000040 elementor-widget elementor-widget-heading\" data-id=\"h000040\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-to-include-in-a-txv-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Qu\u00e9 incluir en una solicitud de oferta de v\u00e1lvula de expansi\u00f3n termost\u00e1tica (TXV)<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000041 elementor-widget elementor-widget-image\" data-id=\"h000041\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq.webp\" class=\"attachment-full size-full wp-image-7068\" alt=\"Dos ingenieros revisando planos t\u00e9cnicos en un entorno industrial moderno.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: Comprador e ingeniero revisando una solicitud de oferta de v\u00e1lvula de expansi\u00f3n termost\u00e1tica con plano de tuber\u00edas, placa de caracter\u00edsticas y muestra de componente.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000042 elementor-widget elementor-widget-text-editor\" data-id=\"h000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una solicitud de oferta s\u00f3lida permite a los proveedores comparar v\u00e1lvulas equivalentes y revela la falta de datos de ingenier\u00eda desde el principio. Adjunte el diagrama P&amp;ID o el croquis de tuber\u00edas y marque los puntos de medici\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000043 elementor-widget elementor-widget-text-editor\" data-id=\"h000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tabla desplazable de v\u00e1lvula de expansi\u00f3n termost\u00e1tica 9\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Campo RFQ<\/th>\n<th>Ejemplo de una entrada \u00fatil<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Aplicaci\u00f3n<\/td>\n<td>C\u00e1mara frigor\u00edfica de temperatura media, congelador de baja temperatura, enfriador de proceso o circuito de bomba de calor<\/td>\n<\/tr>\n<tr>\n<td>Refrigerante<\/td>\n<td>Denominaci\u00f3n exacta, mezcla o nota de sustituci\u00f3n y tipo de aceite si corresponde<\/td>\n<\/tr>\n<tr>\n<td>Capacidad<\/td>\n<td>Capacidad de dise\u00f1o con unidades y rango de funcionamiento requerido<\/td>\n<\/tr>\n<tr>\n<td>Condici\u00f3n de evaporaci\u00f3n<\/td>\n<td>Temperatura de evaporaci\u00f3n de dise\u00f1o y rango esperado<\/td>\n<\/tr>\n<tr>\n<td>Condici\u00f3n de condensaci\u00f3n<\/td>\n<td>Temperatura o presi\u00f3n de condensaci\u00f3n de dise\u00f1o y rango ambiental<\/td>\n<\/tr>\n<tr>\n<td>Condici\u00f3n de l\u00edquido<\/td>\n<td>Temperatura del l\u00edquido, subenfriamiento y presi\u00f3n en la entrada de la v\u00e1lvula TXV<\/td>\n<\/tr>\n<tr>\n<td>Ca\u00edda de presi\u00f3n en la v\u00e1lvula<\/td>\n<td>Ca\u00edda de presi\u00f3n disponible despu\u00e9s de las p\u00e9rdidas aguas arriba y aguas abajo<\/td>\n<\/tr>\n<tr>\n<td>Circuito del evaporador<\/td>\n<td>Cantidad de circuitos, distribuidor, ca\u00edda de presi\u00f3n en el circuito y necesidad de igualador externo<\/td>\n<\/tr>\n<tr>\n<td>Construcci\u00f3n de la v\u00e1lvula<\/td>\n<td>Material del cuerpo, puerto equilibrado o convencional, orificio reemplazable y piezas de servicio<\/td>\n<\/tr>\n<tr>\n<td>Conexiones<\/td>\n<td>Tama\u00f1o de entrada\/salida, tipo de conexi\u00f3n, orientaci\u00f3n y material del tubo<\/td>\n<\/tr>\n<tr>\n<td>Documentaci\u00f3n<\/td>\n<td>Tabla de capacidades, declaraci\u00f3n de compatibilidad, instrucciones de instalaci\u00f3n, repuestos y registros de pruebas<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000044 elementor-widget elementor-widget-text-editor\" data-id=\"h000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Solicite el modelo seleccionado por el proveedor, orificio, carga, disposici\u00f3n del igualador, capacidad nominal en sus condiciones y cualquier l\u00edmite m\u00ednimo o m\u00e1ximo de funcionamiento. \u201cTXV, 7\/8 pulgada\u201d no es una especificaci\u00f3n de compra completa.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000045 elementor-widget elementor-widget-heading\" data-id=\"h000045\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"quality-and-incoming-inspection-checklist\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Lista de verificaci\u00f3n de calidad e inspecci\u00f3n de recepci\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000046 elementor-widget elementor-widget-image\" data-id=\"h000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection.webp\" class=\"attachment-full size-full wp-image-7069\" alt=\"Inspector de calidad asi\u00e1tico comprobando marcas en el cuerpo de la v\u00e1lvula de expansi\u00f3n termost\u00e1tica, bulbo sensor, tubo capilar, conexiones y embalaje\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual: inspector de calidad asi\u00e1tico revisando las marcas del cuerpo de la TXV, bulbo sensor, tubo capilar, conexiones y embalaje.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000047 elementor-widget elementor-widget-text-editor\" data-id=\"h000047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Antes de la instalaci\u00f3n, inspeccione la v\u00e1lvula entregada compar\u00e1ndola con la presentaci\u00f3n aprobada y la lista de embalaje. La verificaci\u00f3n debe ser rastreable al proyecto o n\u00famero de serie del equipo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000048 elementor-widget elementor-widget-text-editor\" data-id=\"h000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Confirme el modelo, orificio, c\u00f3digo de carga, compatibilidad con el refrigerante y tama\u00f1os de conexi\u00f3n.<\/li>\n<li>Revise las marcas del cuerpo, sellos, tapas, bulbo, tubo capilar, accesorio del igualador y accesorios incluidos.<\/li>\n<li>Verifique que las tapas protectoras permanezcan en su lugar hasta que el circuito est\u00e9 listo para el montaje.<\/li>\n<li>Compare las dimensiones recibidas y la direcci\u00f3n del flujo con el plano.<\/li>\n<li>Registre cualquier da\u00f1o, corrosi\u00f3n, contaminaci\u00f3n o tubo capilar doblado antes de la aceptaci\u00f3n.<\/li>\n<li>Conserve la hoja de datos del fabricante y las instrucciones de instalaci\u00f3n en el archivo del equipo.<\/li>\n<li>Despu\u00e9s de la instalaci\u00f3n, registre las lecturas de presi\u00f3n y temperatura como referencia inicial de puesta en marcha.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000049 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"h000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/es\/contacto\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">p\u00e1gina de contacto de Domi<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004a elementor-widget elementor-widget-heading\" data-id=\"h00004a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preguntas frecuentes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004b elementor-widget elementor-widget-heading\" data-id=\"h00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-is-the-main-function-of-a-thermostatic-expansion-valve\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfCu\u00e1l es la funci\u00f3n principal de una v\u00e1lvula de expansi\u00f3n termost\u00e1tica?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004c elementor-widget elementor-widget-text-editor\" data-id=\"h00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una v\u00e1lvula de expansi\u00f3n termost\u00e1tica controla el flujo de refrigerante l\u00edquido hacia un evaporador de expansi\u00f3n directa en respuesta al recalentamiento de salida. Ayuda a mantener el evaporador activo mientras limita la posibilidad de que el l\u00edquido regrese por la l\u00ednea de aspiraci\u00f3n cuando la v\u00e1lvula se selecciona, instala y pone en marcha correctamente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004d elementor-widget elementor-widget-heading\" data-id=\"h00004d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-does-a-txv-maintain-superheat\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo mantiene un VET el sobrecalentamiento?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004e elementor-widget elementor-widget-text-editor\" data-id=\"h00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El bulbo sensor genera una fuerza de apertura a partir de la temperatura de la l\u00ednea de aspiraci\u00f3n. La presi\u00f3n del evaporador y el resorte generan fuerzas de cierre. Su equilibrio mueve el diafragma y modifica la apertura de dosificaci\u00f3n a medida que cambian la carga y el recalentamiento de salida.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004f elementor-widget elementor-widget-heading\" data-id=\"h00004f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"should-i-use-an-internal-or-external-equalizer\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfDebo usar un igualador interno o externo?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000050 elementor-widget elementor-widget-text-editor\" data-id=\"h000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilice el dise\u00f1o de ca\u00edda de presi\u00f3n del evaporador y del distribuidor para decidir. Una v\u00e1lvula igualada internamente puede ser adecuada para un circuito compacto con ca\u00edda de presi\u00f3n limitada. Una v\u00e1lvula igualada externamente se considera com\u00fanmente cuando la p\u00e9rdida de presi\u00f3n a trav\u00e9s de un distribuidor o un evaporador multicircuito significa que la presi\u00f3n del cuerpo de la v\u00e1lvula no representa la salida del evaporador.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000051 elementor-widget elementor-widget-heading\" data-id=\"h000051\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-select-a-txv-from-pipe-size-alone\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfPuedo seleccionar una v\u00e1lvula de expansi\u00f3n termost\u00e1tica solo por el tama\u00f1o de la tuber\u00eda?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000052 elementor-widget elementor-widget-text-editor\" data-id=\"h000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No. El tama\u00f1o de la tuber\u00eda confirma una restricci\u00f3n de conexi\u00f3n, no la capacidad de dosificaci\u00f3n requerida ni la respuesta de control. Seleccione seg\u00fan el refrigerante, carga, condiciones de evaporaci\u00f3n y condensaci\u00f3n, condici\u00f3n del l\u00edquido, ca\u00edda de presi\u00f3n, disposici\u00f3n del igualador, carga del bulbo y los datos de capacidad del fabricante.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000053 elementor-widget elementor-widget-heading\" data-id=\"h000053\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-causes-a-txv-to-hunt\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 causa que una v\u00e1lvula de expansi\u00f3n termost\u00e1tica (VET) oscile?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000054 elementor-widget elementor-widget-text-editor\" data-id=\"h000054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La oscilaci\u00f3n puede resultar de una v\u00e1lvula sobredimensionada, l\u00edquido de entrada inestable, mal contacto o ubicaci\u00f3n del bulbo, una carga inadecuada, cambios en la ca\u00edda de presi\u00f3n, baja carga o una falla del sistema. Registre el recalentamiento a lo largo del tiempo y verifique la alimentaci\u00f3n de l\u00edquido y la instalaci\u00f3n antes de cambiar el ajuste o reemplazar la v\u00e1lvula.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000055 elementor-widget elementor-widget-heading\" data-id=\"h000055\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-a-txv-replacement-rfq-include\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 debe incluir una solicitud de presupuesto para el reemplazo de una v\u00e1lvula de expansi\u00f3n termost\u00e1tica (TXV)?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000056 elementor-widget elementor-widget-text-editor\" data-id=\"h000056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Incluya el modelo y el orificio existentes si se conocen, refrigerante, capacidad, condiciones de evaporaci\u00f3n y condensaci\u00f3n, temperatura del l\u00edquido o subenfriamiento, ca\u00edda de presi\u00f3n disponible, detalles del circuito del evaporador y del distribuidor, m\u00e9todo de igualaci\u00f3n, conexiones, carga del bulbo, rango de aplicaci\u00f3n y documentaci\u00f3n requerida. A\u00f1ada un dibujo de tuber\u00edas cuando el circuito tenga m\u00faltiples ramificaciones o accesorios.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000057 elementor-widget elementor-widget-heading\" data-id=\"h000057\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"primary-technical-references\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Referencias t\u00e9cnicas principales<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000058 elementor-widget elementor-widget-text-editor\" data-id=\"h000058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/R26\/SI\/r26_ch11\/r26_ch11_si.aspx\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">ASHRAE Manual: Dispositivos de control de refrigerante<\/a><\/li>\n<li><a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/how-thermostatic-expansion-valves-work\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss: C\u00f3mo funcionan las v\u00e1lvulas de expansi\u00f3n termost\u00e1tica<\/a><\/li>\n<li><a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/50825\/AX266348279899en-000101.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss: Notas para instaladores: V\u00e1lvulas de expansi\u00f3n termost\u00e1tica<\/a><\/li>\n<li><a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Sporlan\/Sporlan-pdf-files\/Sporlan-pdf-010\/10-11.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan: Bolet\u00edn de instalaci\u00f3n de v\u00e1lvula de expansi\u00f3n termost\u00e1tica<\/a><\/li>\n<li><a href=\"https:\/\/virtualengineer.parker.com\/myprojects\/Sizing\/Sizing?WFID=3f133247-cf7d-f011-b481-000d3a7abe26\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan: Selecci\u00f3n de v\u00e1lvula de expansi\u00f3n con Ingeniero Virtual<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000059 elementor-widget elementor-widget-heading\" data-id=\"h000059\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-articles\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Art\u00edculos Relacionados<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000069 e-con-full e-flex e-con e-parent\" data-id=\"h000069\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h00005e e-con-full e-flex e-con e-parent\" data-id=\"h00005e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h00005b e-con-full e-flex e-con e-parent\" data-id=\"h00005b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005a elementor-widget elementor-widget-text-editor\" data-id=\"h00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/es\/partes-del-sistema-de-refrigeracion\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Partes de un sistema de refrigeraci\u00f3n: nombres de componentes, funciones y aplicaciones<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h00005d e-con-full e-flex e-con e-parent\" data-id=\"h00005d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005c elementor-widget elementor-widget-text-editor\" data-id=\"h00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/es\/ciclo-de-refrigerante\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Ciclo de refrigerante explicado: las 4 etapas y roles del serpent\u00edn<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000063 e-con-full e-flex e-con e-parent\" data-id=\"h000063\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h000060 e-con-full e-flex e-con e-parent\" data-id=\"h000060\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005f elementor-widget elementor-widget-text-editor\" data-id=\"h00005f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/es\/compresor-de-refrigeracion\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Compresor de refrigeraci\u00f3n: Tipos, dimensionamiento y gu\u00eda de selecci\u00f3n OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000062 e-con-full e-flex e-con e-parent\" data-id=\"h000062\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000061 elementor-widget elementor-widget-text-editor\" data-id=\"h000061\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/es\/guia-de-controles-de-refrigeracion\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Gu\u00eda de controles de refrigeraci\u00f3n: tipos, funciones y datos para solicitudes de cotizaci\u00f3n (RFQ)<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000068 e-con-full e-flex e-con e-parent\" data-id=\"h000068\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h000065 e-con-full e-flex e-con e-parent\" data-id=\"h000065\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000064 elementor-widget elementor-widget-text-editor\" data-id=\"h000064\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/es\/controlador-de-refrigeracion\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Controlador de refrigeraci\u00f3n: Gu\u00eda de selecci\u00f3n de temperatura, desescarche y alarma<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000067 e-con-full e-flex e-con e-parent\" data-id=\"h000067\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000066 elementor-widget elementor-widget-text-editor\" data-id=\"h000066\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/es\/guia-de-seleccion-de-unidades-de-refrigeracion\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Gu\u00eda de selecci\u00f3n de unidades de refrigeraci\u00f3n para sistemas comerciales y OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00006a elementor-align-left elementor-widget elementor-widget-button\" data-id=\"h00006a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/es\/contacto\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Env\u00ede su dibujo de refrigeraci\u00f3n para revisi\u00f3n<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Aprenda c\u00f3mo una v\u00e1lvula de expansi\u00f3n termost\u00e1tica controla el sobrecalentamiento, c\u00f3mo dimensionar una VET y qu\u00e9 refrigerante, carga, presi\u00f3n y entradas para solicitud de presupuesto deben confirmar los compradores.<\/p>","protected":false},"author":1,"featured_media":7059,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7070","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts\/7070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/comments?post=7070"}],"version-history":[{"count":4,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts\/7070\/revisions"}],"predecessor-version":[{"id":7096,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts\/7070\/revisions\/7096"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/media\/7059"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/media?parent=7070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/categories?post=7070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/tags?post=7070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}