{"id":7147,"date":"2026-10-06T00:38:24","date_gmt":"2026-10-05T16:38:24","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7147"},"modified":"2026-10-06T00:38:24","modified_gmt":"2026-10-05T16:38:24","slug":"guia-de-diseno-de-tuberias-de-refrigerante","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/es\/refrigerant-piping-design-guide\/","title":{"rendered":"Gu\u00eda de dise\u00f1o de tuber\u00edas de refrigerante: dimensionamiento de l\u00edneas, trazado y comprobaciones del fabricante original (OEM)"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7147\" class=\"elementor elementor-7147\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000060 e-con-full e-flex e-con e-parent\" data-id=\"nr000060\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000002 e-con-full e-flex e-con e-parent\" data-id=\"nr000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000001 elementor-widget elementor-widget-text-editor\" data-id=\"nr000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las tuber\u00edas de refrigerante conectan el compresor, el condensador, el dispositivo de expansi\u00f3n y el evaporador. Dimensione y trace cada segmento para el refrigerante seleccionado, las condiciones de operaci\u00f3n, el rango de capacidad, la longitud real de la l\u00ednea, la elevaci\u00f3n y el equipo conectado. La tuber\u00eda de succi\u00f3n debe retornar el aceite a la carga m\u00ednima esperada manteniendo la p\u00e9rdida de presi\u00f3n dentro de los l\u00edmites del compresor. La tuber\u00eda de l\u00edquido debe entregar l\u00edquido al dispositivo de expansi\u00f3n sin vaporizaci\u00f3n s\u00fabita (flash).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000003 elementor-widget elementor-widget-text-editor\" data-id=\"nr000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una conexi\u00f3n de equipo es un tama\u00f1o de puerto, no una especificaci\u00f3n de la l\u00ednea de campo. <a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Gu\u00eda de tuber\u00edas para c\u00e1maras frigor\u00edficas de Danfoss<\/a> trata el tama\u00f1o de la l\u00ednea en funci\u00f3n del refrigerante, la capacidad, la longitud del recorrido, la elevaci\u00f3n y las temperaturas de operaci\u00f3n. Utilice los datos del compresor seleccionado y del fabricante del equipo para el rango de operaci\u00f3n real.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000004 elementor-widget elementor-widget-image\" data-id=\"nr000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop.webp\" class=\"attachment-full size-full wp-image-7136\" alt=\"Cuarto fr\u00edo con un condensador exterior, una central de compresores, tuber\u00edas elevadas y una unidad evaporadora.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Resumen del sistema generado. No es una instalaci\u00f3n de Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000005 elementor-widget elementor-widget-heading\" data-id=\"nr000005\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-main-refrigerant-line-types\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfCu\u00e1les son los principales tipos de l\u00edneas de refrigerante?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000006 elementor-widget elementor-widget-text-editor\" data-id=\"nr000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un sistema de compresi\u00f3n de vapor suele tener tres funciones principales de l\u00ednea. Los sistemas complejos pueden a\u00f1adir ramificaciones, colectores, l\u00edneas de descongelaci\u00f3n por gas caliente, l\u00edneas de economizador o trayectos reversibles de bomba de calor. El nombre de la l\u00ednea describe su estado de refrigerante y direcci\u00f3n del flujo, as\u00ed que confirme el circuito real en el esquema del proyecto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000007 elementor-widget elementor-widget-text-editor\" data-id=\"nr000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Una l\u00ednea de succi\u00f3n transporta vapor desde la salida del evaporador hasta la entrada del compresor. Verifique el retorno de aceite a la capacidad m\u00ednima y mantenga la ca\u00edda de presi\u00f3n de succi\u00f3n dentro de los l\u00edmites del compresor.<\/li>\n<li>Una l\u00ednea de descarga transporta gas caliente desde el compresor hasta el condensador. Revise la clasificaci\u00f3n de presi\u00f3n, la temperatura, la vibraci\u00f3n y la migraci\u00f3n de refrigerante o aceite.<\/li>\n<li>Una l\u00ednea de l\u00edquido va desde el condensador o recibidor hasta el dispositivo de expansi\u00f3n. Verifique la ca\u00edda de presi\u00f3n para que el l\u00edquido llegue al dispositivo de expansi\u00f3n sin vaporizaci\u00f3n s\u00fabita.<\/li>\n<li>Las ramificaciones y las l\u00edneas de servicio especial gestionan colectores, descongelaci\u00f3n por gas caliente, economizadores o circuitos reversibles. Siga el esquema del equipo y las instrucciones de cada componente.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000008 elementor-widget elementor-widget-image\" data-id=\"nr000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families.webp\" class=\"attachment-full size-full wp-image-7134\" alt=\"Compresor de refrigeraci\u00f3n comercial e intercambiadores de calor conectados mediante rutas de l\u00edneas de succi\u00f3n, descarga y l\u00edquido.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Ilustraci\u00f3n conceptual. Confirme el circuito real a partir del esquema del proyecto.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000009 elementor-widget elementor-widget-text-editor\" data-id=\"nr000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una l\u00ednea seleccionada en un punto de operaci\u00f3n puede no funcionar en todo el rango. <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEM&amp;PDF=AE-105\" target=\"_blank\" rel=\"noopener\">Manual de refrigeraci\u00f3n de Copeland<\/a> analiza el retorno de aceite en las l\u00edneas de succi\u00f3n principales y de ramificaci\u00f3n a carga m\u00ednima, as\u00ed como la ca\u00edda de presi\u00f3n en las l\u00edneas de l\u00edquido y de gas caliente. Una regla de di\u00e1metro \u00fanico no puede cubrir esas diferentes condiciones. Para el ciclo de cuatro etapas y la funci\u00f3n de cada intercambiador de calor, consulte el <a href=\"https:\/\/domirefrigeration.com\/es\/ciclo-de-refrigerante\/\">documento gu\u00eda del ciclo de refrigerante<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000a elementor-widget elementor-widget-heading\" data-id=\"nr00000a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"which-inputs-determine-refrigerant-line-size\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 entradas determinan el tama\u00f1o de la l\u00ednea de refrigerante?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000b elementor-widget elementor-widget-text-editor\" data-id=\"nr00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Comience con el rango de operaci\u00f3n, no con el di\u00e1metro exterior impreso en un conector. Anote los siguientes datos antes de elegir una tabla de tuber\u00edas o una herramienta de selecci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000c elementor-widget elementor-widget-text-editor\" data-id=\"nr00000c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Tipo de refrigerante y de aceite, incluidas las alternativas aprobadas.<\/li>\n<li>Capacidad de refrigeraci\u00f3n requerida en cada condici\u00f3n de dise\u00f1o, no solo la potencia nominal.<\/li>\n<li>Temperaturas o presiones de evaporaci\u00f3n y condensaci\u00f3n, recalentamiento y subenfriamiento seg\u00fan lo requiera la herramienta.<\/li>\n<li>Modelo de compresor, m\u00e9todo de control de capacidad y puntos de operaci\u00f3n m\u00ednimo y m\u00e1ximo.<\/li>\n<li>Funci\u00f3n de la l\u00ednea: aspiraci\u00f3n, descarga, l\u00edquido, gas caliente o una derivaci\u00f3n.<\/li>\n<li>Longitud real del recorrido, longitud equivalente de accesorios, desnivel vertical o bajada, y la ubicaci\u00f3n de cada componente.<\/li>\n<li>Condiciones de inversi\u00f3n de bomba de calor, descongelaci\u00f3n, parada y carga parcial que cambien la direcci\u00f3n del flujo o el flujo m\u00e1sico.<\/li>\n<li>Material del tubo, m\u00e9todo de conexi\u00f3n, l\u00edmites de presi\u00f3n y temperatura, aislamiento, soportes y requisitos de los c\u00f3digos locales.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000d elementor-widget elementor-widget-image\" data-id=\"nr00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs.webp\" class=\"attachment-full size-full wp-image-7137\" alt=\"Ingeniero revisando una ruta de tuber\u00edas de refrigeraci\u00f3n y un programa de equipos junto a un sistema comercial.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Escena conceptual generada, no un registro de un proyecto de Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000e elementor-widget elementor-widget-text-editor\" data-id=\"nr00000e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">La gu\u00eda de dise\u00f1o de sistemas de Danfoss<\/a> enumera el refrigerante, la capacidad, la longitud de la l\u00ednea, la altura y la temperatura de operaci\u00f3n entre los datos de entrada para las tuber\u00edas de c\u00e1maras frigor\u00edficas. Tambi\u00e9n separa las comprobaciones para las l\u00edneas de l\u00edquido, aspiraci\u00f3n y descarga. Utilice las instrucciones del fabricante seleccionado o un software de dimensionamiento aprobado para convertir esos datos en un tama\u00f1o candidato. Para obtener contexto sobre la selecci\u00f3n de compresores, consulte la <a href=\"https:\/\/domirefrigeration.com\/es\/compresor-de-refrigeracion\/\">gu\u00eda de compresores de refrigeraci\u00f3n<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000f elementor-widget elementor-widget-heading\" data-id=\"nr00000f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-size-refrigerant-lines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo se dimensionan las l\u00edneas de refrigerante?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000010 elementor-widget elementor-widget-text-editor\" data-id=\"nr000010\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilice una secuencia repetible para cada segmento del sistema. No seleccione la tuber\u00eda bas\u00e1ndose \u00fanicamente en el tonelaje nominal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000011 elementor-widget elementor-widget-text-editor\" data-id=\"nr000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li><strong>Fije el caso de dise\u00f1o.<\/strong> Confirme el refrigerante, las condiciones de evaporaci\u00f3n y condensaci\u00f3n, la carga t\u00e9rmica, el rango ambiental y los modos de operaci\u00f3n.<\/li>\n<li><strong>Dibuje los segmentos de l\u00ednea.<\/strong> Marque por separado las l\u00edneas de aspiraci\u00f3n, l\u00edquido, descarga y servicio especial. Registre las derivaciones, colectores, cambios verticales y conexiones de equipos.<\/li>\n<li><strong>Mida el recorrido.<\/strong> Incluya la longitud recta, los accesorios, la elevaci\u00f3n y las restricciones de trazado. Un esquema que omita el recorrido puede no ser v\u00e1lido para un tama\u00f1o definitivo.<\/li>\n<li><strong>Seleccione un candidato en la herramienta o las tablas del fabricante del equipo.<\/strong> Use los datos del refrigerante y la familia de compresores especificados. No transfiera el valor de una tabla a otro refrigerante o rango de operaci\u00f3n sin confirmaci\u00f3n.<\/li>\n<li><strong>Compruebe la ca\u00edda de presi\u00f3n y el flujo m\u00e1sico.<\/strong> Revise cada l\u00ednea en las condiciones de dise\u00f1o. La l\u00ednea de l\u00edquido debe mantener el suministro de l\u00edquido al dispositivo de expansi\u00f3n; la p\u00e9rdida de presi\u00f3n en la succi\u00f3n afecta las condiciones de entrada del compresor.<\/li>\n<li><strong>Compruebe el retorno de aceite con la carga m\u00ednima esperada.<\/strong> Los compresores de velocidad variable y los sistemas escalonados requieren una comprobaci\u00f3n a carga parcial. Una l\u00ednea seleccionada \u00fanicamente para carga plena puede no desplazar el aceite de forma fiable cuando el flujo m\u00e1sico disminuye.<\/li>\n<li><strong>Revise los l\u00edmites de instalaci\u00f3n y presi\u00f3n.<\/strong> Confirme el material de la tuber\u00eda, la presi\u00f3n nominal, el m\u00e9todo de uni\u00f3n, los soportes, el aislamiento, el control de vibraciones y las normas de seguridad aplicables.<\/li>\n<li><strong>Conserve el c\u00e1lculo junto con el plano.<\/strong> Registre la referencia de la herramienta o del fabricante, las hip\u00f3tesis, el di\u00e1metro de tuber\u00eda seleccionado y el revisor para poder verificar futuros cambios de equipos o refrigerantes.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000012 elementor-widget elementor-widget-image\" data-id=\"nr000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff.webp\" class=\"attachment-full size-full wp-image-7138\" alt=\"Comparaci\u00f3n conceptual de di\u00e1metros alternativos de tubos de succi\u00f3n que ilustran las compensaciones entre velocidad y ca\u00edda de presi\u00f3n.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Solo comparaci\u00f3n de conceptos. Seleccione el di\u00e1metro de la tuber\u00eda para el rango de operaci\u00f3n real.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000013 elementor-widget elementor-widget-text-editor\" data-id=\"nr000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El resultado \u00fatil es un dise\u00f1o documentado para el rango de operaci\u00f3n especificado, no una tabla universal de di\u00e1metros de tuber\u00eda. Si cambian el refrigerante, el rango de velocidad del compresor, la condici\u00f3n de evaporaci\u00f3n o el trazado, vuelva a realizar la selecci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000014 elementor-widget elementor-widget-heading\" data-id=\"nr000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"why-is-the-unit-connection-size-not-always-the-field-line-size\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfPor qu\u00e9 el tama\u00f1o de la conexi\u00f3n de la unidad no siempre coincide con el tama\u00f1o de la tuber\u00eda de campo?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000015 elementor-widget elementor-widget-text-editor\" data-id=\"nr000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La conexi\u00f3n de un compresor, condensador o unidad condensadora es una interfaz de componentes. La l\u00ednea de interconexi\u00f3n tiene su propio trazado, longitud, caudal y desnivel. Un puerto y una l\u00ednea de campo pueden tener el mismo di\u00e1metro en un dise\u00f1o determinado, pero el puerto por s\u00ed solo no determina dicha elecci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000016 elementor-widget elementor-widget-text-editor\" data-id=\"nr000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En una <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/580178\/AB399636244436en-000301.pdf\" target=\"_blank\" rel=\"noopener\">gu\u00eda de aplicaci\u00f3n de unidades condensadoras Danfoss espec\u00edfica para un modelo<\/a>, el fabricante advierte a los usuarios que no deben asumir que las conexiones de succi\u00f3n y l\u00edquido de la unidad tienen el tama\u00f1o correcto para la tuber\u00eda de interconexi\u00f3n. Dicha gu\u00eda tambi\u00e9n exige dimensionar en funci\u00f3n del rango de capacidad de la unidad. Es un ejemplo de aplicaci\u00f3n, pero demuestra por qu\u00e9 la dimensi\u00f3n de un puerto por s\u00ed sola no puede fijar el tama\u00f1o de la tuber\u00eda de campo. Confirme el programa de tuber\u00edas aprobado en los datos del fabricante del equipo antes de la fabricaci\u00f3n o la instalaci\u00f3n. Durante la revisi\u00f3n de los planos, trate cada puerto como una interfaz y, a continuaci\u00f3n, compruebe todo el trazado con los datos del equipo seleccionado.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000017 elementor-widget elementor-widget-image\" data-id=\"nr000017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs.webp\" class=\"attachment-full size-full wp-image-7139\" alt=\"Tubos de conexi\u00f3n cortos de la unidad condensadora junto a tuber\u00edas de campo separadas que pasan por una zona de la planta.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">El puerto de un componente no determina el tama\u00f1o de la tuber\u00eda de campo.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000018 elementor-widget elementor-widget-text-editor\" data-id=\"nr000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para un conjunto OEM, env\u00ede el plano, el refrigerante, el objetivo de capacidad y el programa de tuber\u00edas juntos. Esto proporciona al revisor el contexto necesario para evaluar el puerto de un conjunto frente a todo el tramo de interconexi\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000019 elementor-widget elementor-widget-heading\" data-id=\"nr000019\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-part-load-systems-change-suction-line-design\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo afectan los sistemas a carga parcial al dise\u00f1o de la l\u00ednea de succi\u00f3n?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001a elementor-widget elementor-widget-text-editor\" data-id=\"nr00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El funcionamiento a carga parcial genera un compromiso de dise\u00f1o. Una l\u00ednea de succi\u00f3n grande puede reducir la ca\u00edda de presi\u00f3n a plena carga, pero la velocidad del gas puede disminuir demasiado como para garantizar el retorno de aceite cuando la capacidad o la velocidad del compresor son bajas. Una l\u00ednea m\u00e1s peque\u00f1a puede mantener la velocidad a baja carga, pero genera una mayor ca\u00edda de presi\u00f3n con un flujo superior.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001b elementor-widget elementor-widget-text-editor\" data-id=\"nr00001b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Algunas aplicaciones de compresores utilizan una tuber\u00eda vertical dividida o doble en un amplio rango de capacidad. La ruta m\u00e1s peque\u00f1a puede mantener el retorno de aceite a capacidad reducida; ambas rutas transportan flujo a mayor carga. Esta disposici\u00f3n depende del compresor y de las condiciones de operaci\u00f3n, por lo que no es un atajo de adaptaci\u00f3n. <a href=\"https:\/\/www.bitzer.de\/shared_media\/html\/est-600\/en-GB\/556451979556454155.html\" target=\"_blank\" rel=\"noopener\">La gu\u00eda de dise\u00f1o de tuber\u00edas de BITZER<\/a> describe las tuber\u00edas verticales divididas para sistemas con control de capacidad y la necesidad de verificar el retorno de aceite a carga m\u00ednima.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001c elementor-widget elementor-widget-image\" data-id=\"nr00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser.webp\" class=\"attachment-full size-full wp-image-7142\" alt=\"Columna de aspiraci\u00f3n dividida conceptual con ramales verticales m\u00e1s grandes y m\u00e1s peque\u00f1os entre colectores comunes.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Disposici\u00f3n conceptual. Confirme el dise\u00f1o con los datos de aplicaci\u00f3n del compresor.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001d elementor-widget elementor-widget-text-editor\" data-id=\"nr00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Solicite al proveedor del compresor o al dise\u00f1ador del sistema que confirme:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001e elementor-widget elementor-widget-text-editor\" data-id=\"nr00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Si el compresor es de velocidad fija, escalonada o variable.<\/li>\n<li>El flujo m\u00e1sico y la velocidad estables m\u00ednimos.<\/li>\n<li>La elevaci\u00f3n vertical prevista y el programa de funcionamiento.<\/li>\n<li>Si se aprueba una sola tuber\u00eda vertical, una tuber\u00eda vertical dividida u otra disposici\u00f3n.<\/li>\n<li>C\u00f3mo se verificar\u00e1 el retorno de aceite durante la puesta en marcha.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001f elementor-widget elementor-widget-text-editor\" data-id=\"nr00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No copie un objetivo de velocidad de un manual a otro sistema. Los valores publicados se aplican al compresor, refrigerante, rango de capacidad e instrucciones citados.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000020 elementor-widget elementor-widget-heading\" data-id=\"nr000020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-material-should-refrigerant-piping-use\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 material deben utilizar las tuber\u00edas de refrigerante?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000021 elementor-widget elementor-widget-text-editor\" data-id=\"nr000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los tubos de cobre ACR son comunes para conexiones de campo en muchas aplicaciones de refrigeraci\u00f3n. <a href=\"https:\/\/store.astm.org\/b0280-23.html\" target=\"_blank\" rel=\"noopener\">ASTM B280-23<\/a> especifica tubos de cobre sin costura para servicio de campo en aire acondicionado y refrigeraci\u00f3n. La norma no selecciona el espesor de pared, el di\u00e1metro, el m\u00e9todo de uni\u00f3n ni la presi\u00f3n nominal para un sistema particular.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000022 elementor-widget elementor-widget-text-editor\" data-id=\"nr000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La selecci\u00f3n del material debe coincidir con el refrigerante, el rango de presi\u00f3n y temperatura, las aprobaciones de los componentes, el m\u00e9todo de uni\u00f3n, el entorno y los requisitos locales. Los sistemas de CO2 operan a condiciones de presi\u00f3n que requieren equipos y tuber\u00edas dise\u00f1ados para esa aplicaci\u00f3n. Los sistemas A2L tambi\u00e9n tienen requisitos de instalaci\u00f3n y seguridad espec\u00edficos del refrigerante. Confirme los tubos y accesorios con la presi\u00f3n de dise\u00f1o y las instrucciones del sistema exacto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000023 elementor-widget elementor-widget-image\" data-id=\"nr000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure.webp\" class=\"attachment-full size-full wp-image-7140\" alt=\"Tuber\u00eda de cobre ACR junto a v\u00e1lvulas y accesorios de refrigeraci\u00f3n en una comparativa de materiales conceptual.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">El material y la presi\u00f3n nominal deben especificarse para la aplicaci\u00f3n.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000024 elementor-widget elementor-widget-text-editor\" data-id=\"nr000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un plano de adquisici\u00f3n debe indicar la norma del tubo y el material cuando se conozca. Si la especificaci\u00f3n est\u00e1 incompleta, ind\u00edquelo como un elemento de ingenier\u00eda pendiente en lugar de asumir que cualquier tubo o accesorio de cobre funcionar\u00e1.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000025 elementor-widget elementor-widget-heading\" data-id=\"nr000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-route-length-and-fittings-affect-pressure-drop\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo afectan la longitud del recorrido y los accesorios a la ca\u00edda de presi\u00f3n?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000026 elementor-widget elementor-widget-text-editor\" data-id=\"nr000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El recorrido de la tuber\u00eda afecta la ca\u00edda de presi\u00f3n, la carga de refrigerante, el movimiento del aceite, el acceso para servicio y el costo de instalaci\u00f3n. Los recorridos largos, muchos codos, ramales de di\u00e1metro insuficiente, reducciones abruptas y elevaciones mal ubicadas pueden alterar el resultado que sugiere una tabla de tuber\u00edas rectas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000027 elementor-widget elementor-widget-text-editor\" data-id=\"nr000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Mantenga los tramos tan cortos como lo permita la disposici\u00f3n de los equipos. Utilice el m\u00e9todo de accesorios y longitud equivalente requerido por la herramienta de dimensionamiento del fabricante. Agregue los cambios de elevaci\u00f3n y la geometr\u00eda de las derivaciones al modelo, y luego verifique el punto de operaci\u00f3n menos favorable. No sustituya el c\u00e1lculo de ca\u00edda de presi\u00f3n por una estimaci\u00f3n visual.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000028 elementor-widget elementor-widget-image\" data-id=\"nr000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length.webp\" class=\"attachment-full size-full wp-image-7141\" alt=\"Unidades de refrigeraci\u00f3n comercial conectadas por rutas de tuber\u00edas con diferentes longitudes y cambios de direcci\u00f3n.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Rutas ilustrativas. Verifique las longitudes reales de los accesorios y de elevaci\u00f3n en la herramienta seleccionada.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000029 elementor-widget elementor-widget-text-editor\" data-id=\"nr000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">La gu\u00eda de tuber\u00edas de Danfoss<\/a> aconseja minimizar los cambios de direcci\u00f3n innecesarios y evitar pandeos que puedan crear trampas de aceite no deseadas. Mantenga accesibles las v\u00e1lvulas de servicio, las conexiones del compresor, los visores de l\u00edquido y los paneles desmontables. Isle cada l\u00ednea cuando las instrucciones del equipo y las condiciones de funcionamiento lo requieran.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002a elementor-widget elementor-widget-heading\" data-id=\"nr00002a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-the-installation-drawing-show\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 debe mostrar el plano de instalaci\u00f3n?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002b elementor-widget elementor-widget-text-editor\" data-id=\"nr00002b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un plano de campo \u00fatil permite al instalador montar e inspeccionar la ruta prevista. La ilustraci\u00f3n generada a continuaci\u00f3n muestra elementos de ejemplo del plano; no est\u00e1 lista para la construcci\u00f3n. Enumere estos elementos espec\u00edficos del proyecto:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002c elementor-widget elementor-widget-image\" data-id=\"nr00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing.webp\" class=\"attachment-full size-full wp-image-7144\" alt=\"Esquema conceptual de tuber\u00edas de refrigeraci\u00f3n que muestra un ramal, cambios verticales, soportes y acceso a los equipos.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Diagrama conceptual, no es un plano listo para construcci\u00f3n ni acotado.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002d elementor-widget elementor-widget-text-editor\" data-id=\"nr00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Direcci\u00f3n del flujo y funci\u00f3n de la l\u00ednea para cada segmento.<\/li>\n<li>Material de la tuber\u00eda, di\u00e1metro exterior o designaci\u00f3n nominal, y especificaci\u00f3n de la pared cuando corresponda.<\/li>\n<li>Accesorios, derivaciones, reductores, trampas, columnas montantes y componentes de aislamiento o servicio.<\/li>\n<li>Ubicaciones de conexi\u00f3n de los equipos y la tabla de conexiones aprobada.<\/li>\n<li>L\u00edmites de aislamiento, puntos de soporte, penetraciones y detalles de control de vibraciones.<\/li>\n<li>Presi\u00f3n y temperatura de dise\u00f1o cuando sea necesario para la selecci\u00f3n de materiales y componentes.<\/li>\n<li>Condiciones especiales para descongelaci\u00f3n por gas caliente, inversi\u00f3n de bomba de calor, vaciado (pump-down) o funcionamiento a baja carga.<\/li>\n<li>La revisi\u00f3n del plano y la fuente de los datos de dimensionamiento.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002e elementor-widget elementor-widget-image\" data-id=\"nr00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration.webp\" class=\"attachment-full size-full wp-image-7143\" alt=\"L\u00edneas de refrigeraci\u00f3n de cobre aisladas y con soporte junto a un compresor con un conector flexible.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Imagen conceptual generada, no evidencia de instalaci\u00f3n de Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002f elementor-widget elementor-widget-text-editor\" data-id=\"nr00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEM&amp;PDF=AE-105\" target=\"_blank\" rel=\"noopener\">Manual de refrigeraci\u00f3n de Copeland<\/a> cubre soportes de tuber\u00edas, trampas de aceite, vibraciones y protecci\u00f3n de tubos. Siga el espaciado de soportes y el procedimiento de uni\u00f3n especificados para el equipo y el proyecto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000030 elementor-widget elementor-widget-heading\" data-id=\"nr000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-can-commissioning-checks-confirm-the-piping-design\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo pueden las comprobaciones de la puesta en marcha confirmar el dise\u00f1o de las tuber\u00edas?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000031 elementor-widget elementor-widget-text-editor\" data-id=\"nr000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los registros de puesta en marcha deben comparar el comportamiento real del sistema con el dise\u00f1o aprobado. Un t\u00e9cnico o ingeniero de refrigeraci\u00f3n cualificado puede comprobar las condiciones de funcionamiento y los puntos relevantes para el equipo seleccionado.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000032 elementor-widget elementor-widget-text-editor\" data-id=\"nr000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Registre el refrigerante, la condici\u00f3n ambiente, el estado de carga, la etapa o velocidad del compresor, las condiciones de aspiraci\u00f3n y descarga, la condici\u00f3n de la l\u00ednea de l\u00edquido y los lugares de medici\u00f3n. Compare la ca\u00edda de presi\u00f3n y las temperaturas de funcionamiento con los l\u00edmites del fabricante. Para sistemas de capacidad variable, incluya el punto de funcionamiento m\u00e1s bajo que el plan de puesta en marcha pueda probar de forma segura.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000033 elementor-widget elementor-widget-image\" data-id=\"nr000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning.webp\" class=\"attachment-full size-full wp-image-7145\" alt=\"T\u00e9cnico midiendo la presi\u00f3n de refrigeraci\u00f3n y la temperatura de la l\u00ednea en un punto de servicio del compresor.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Imagen conceptual generada, no es una prueba real ni un registro de servicio de Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000034 elementor-widget elementor-widget-text-editor\" data-id=\"nr000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>S\u00edntomas como baja presi\u00f3n de succi\u00f3n, nivel de aceite deficiente, gas flash, vibraci\u00f3n o rendimiento irregular del serpent\u00edn pueden tener varias causas. No demuestran que una tuber\u00eda sea de tama\u00f1o insuficiente. Confirme los instrumentos, la carga, los controles, las restricciones, el flujo de aire y el estado del equipo antes de cambiar el dise\u00f1o de la l\u00ednea. La manipulaci\u00f3n de refrigerantes, la soldadura fuerte, las pruebas de presi\u00f3n y la recuperaci\u00f3n deben ser realizadas por personal cualificado utilizando los procedimientos de seguridad aplicables.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000035 elementor-widget elementor-widget-heading\" data-id=\"nr000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-an-oem-include-in-a-refrigerant-piping-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 debe incluir un OEM en una solicitud de cotizaci\u00f3n (RFQ) de tuber\u00edas de refrigerante?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000036 elementor-widget elementor-widget-text-editor\" data-id=\"nr000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para una revisi\u00f3n \u00fatil de las tuber\u00edas, env\u00ede el l\u00edmite del sistema y el caso operativo. Incluya un diagrama unifilar con el plano; el tama\u00f1o del puerto de un compresor por s\u00ed solo no describe la ruta.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000037 elementor-widget elementor-widget-text-editor\" data-id=\"nr000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Aplicaci\u00f3n: tipo de equipo, rango de temperatura, ubicaci\u00f3n interior o exterior y ciclo de trabajo.<\/li>\n<li>Refrigerante: refrigerante exacto, aceite y cualquier alternativa aprobada.<\/li>\n<li>Capacidad y condiciones: capacidad de dise\u00f1o, condiciones de evaporaci\u00f3n y condensaci\u00f3n, rango ambiente y carga m\u00ednima y m\u00e1xima.<\/li>\n<li>Equipos: compresor, condensador, evaporador, dispositivo de expansi\u00f3n y datos de conexi\u00f3n.<\/li>\n<li>Ruta: longitudes de los tramos, cambios de nivel, accesorios, derivaciones y l\u00edmites de instalaci\u00f3n.<\/li>\n<li>Materiales: norma del tubo, material, m\u00e9todo de conexi\u00f3n, presi\u00f3n de dise\u00f1o, aislamiento y acabado.<\/li>\n<li>Modos de operaci\u00f3n: carga parcial, escalonamiento, velocidad variable, descongelaci\u00f3n, vaciado (pump-down) o inversi\u00f3n de bomba de calor.<\/li>\n<li>Documentos: esquema de tuber\u00edas, tablas de equipos, referencia de dimensionamiento y revisi\u00f3n de planos.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000038 elementor-widget elementor-widget-image\" data-id=\"nr000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing.webp\" class=\"attachment-full size-full wp-image-7146\" alt=\"Esquema de tuber\u00edas, tabla de equipos y muestras de accesorios dispuestos para una revisi\u00f3n de dise\u00f1o de OEM.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Paquete conceptual. No contiene datos reales de clientes ni de proyectos.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000039 elementor-widget elementor-widget-text-editor\" data-id=\"nr000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si el sistema incluye un intercambiador de calor personalizado o un conjunto de unidad condensadora, incluya la interfaz de tuber\u00edas en el mismo juego de planos que la capacidad del serpent\u00edn, el refrigerante, las conexiones y la envolvente de instalaci\u00f3n. La p\u00e1gina de ingenier\u00eda de Domi describe el soporte para los requisitos de transferencia de calor y la revisi\u00f3n de planos en proyectos de intercambiadores de calor. Confirme el alcance de ingenier\u00eda solicitado con el equipo antes de utilizarlo para el dise\u00f1o completo de las tuber\u00edas del sistema.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003a elementor-widget elementor-widget-heading\" data-id=\"nr00003a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preguntas frecuentes<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003b elementor-widget elementor-widget-heading\" data-id=\"nr00003b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-different-types-of-refrigerant-pipes\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfCu\u00e1les son los diferentes tipos de tuber\u00edas de refrigerante?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003c elementor-widget elementor-widget-text-editor\" data-id=\"nr00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Las tres funciones principales de las l\u00edneas comunes son succi\u00f3n, descarga y l\u00edquido. Un sistema m\u00e1s grande tambi\u00e9n puede incluir derivaciones, colectores, descongelaci\u00f3n por gas caliente, economizador o l\u00edneas reversibles de bomba de calor. El esquema y el estado del refrigerante determinan el nombre correcto y la comprobaci\u00f3n del dise\u00f1o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003d elementor-widget elementor-widget-heading\" data-id=\"nr00003d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-material-is-used-for-refrigerant-piping\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 material se utiliza para las tuber\u00edas de refrigerante?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003e elementor-widget elementor-widget-text-editor\" data-id=\"nr00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El tubo de cobre ACR fabricado seg\u00fan la norma ASTM B280 es com\u00fan en los trabajos de refrigeraci\u00f3n de campo. Las especificaciones del material y del espesor de pared siguen dependientes del refrigerante, la presi\u00f3n de dise\u00f1o, la temperatura, los accesorios, la homologaci\u00f3n del equipo y el c\u00f3digo. No utilice una etiqueta de material gen\u00e9rica como sustituto de la especificaci\u00f3n del sistema.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003f elementor-widget elementor-widget-heading\" data-id=\"nr00003f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-size-refrigerant-lines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfC\u00f3mo se dimensionan las l\u00edneas de refrigerante?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000040 elementor-widget elementor-widget-text-editor\" data-id=\"nr000040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilice la tabla o la herramienta de dimensionamiento del fabricante del equipo seleccionado con el refrigerante, la capacidad, las condiciones de evaporaci\u00f3n y condensaci\u00f3n, la longitud de la ruta, la elevaci\u00f3n, los accesorios y el rango de capacidad completo. Verifique el retorno de aceite por succi\u00f3n a carga m\u00ednima y la ca\u00edda de presi\u00f3n en los puntos de operaci\u00f3n requeridos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000041 elementor-widget elementor-widget-heading\" data-id=\"nr000041\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"are-refrigerant-line-sizes-standard\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfSon est\u00e1ndar los tama\u00f1os de las l\u00edneas de refrigerante?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000042 elementor-widget elementor-widget-text-editor\" data-id=\"nr000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los tubos est\u00e1n disponibles en tama\u00f1os est\u00e1ndar, pero una lista de tama\u00f1os est\u00e1ndar no identifica el tama\u00f1o correcto para un sistema. Utilice el refrigerante, las condiciones de operaci\u00f3n, el recorrido de la l\u00ednea, la capacidad, el l\u00edmite de presi\u00f3n y las instrucciones del fabricante para seleccionar la tuber\u00eda.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000043 elementor-widget elementor-widget-heading\" data-id=\"nr000043\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-use-the-same-size-as-the-compressor-connection\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfPuedo usar el mismo tama\u00f1o que la conexi\u00f3n del compresor?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000044 elementor-widget elementor-widget-text-editor\" data-id=\"nr000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No autom\u00e1ticamente. La conexi\u00f3n del compresor es una dimensi\u00f3n de puerto. La tuber\u00eda de interconexi\u00f3n debe seleccionarse para todo el circuito y el rango de operaci\u00f3n. Verifique los datos del equipo aprobado y el c\u00e1lculo de la l\u00ednea.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000045 elementor-widget elementor-widget-heading\" data-id=\"nr000045\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-a-larger-suction-line-always-improve-performance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfUna l\u00ednea de succi\u00f3n m\u00e1s grande siempre mejora el rendimiento?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000046 elementor-widget elementor-widget-text-editor\" data-id=\"nr000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No. Un di\u00e1metro mayor puede reducir la fricci\u00f3n con un caudal m\u00e1s alto, \u0995\u09bf\u09a8\u09cd\u09a4\u09c1 tambi\u00e9n puede reducir la velocidad del gas cuando el sistema opera a baja capacidad. La selecci\u00f3n debe equilibrar la ca\u00edda de presi\u00f3n y el retorno de aceite en todo el rango de carga real.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000047 elementor-widget elementor-widget-heading\" data-id=\"nr000047\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-co2-use-the-same-refrigerant-piping-as-an-hfc-system\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfUtiliza el CO2 las mismas tuber\u00edas de refrigerante que un sistema HFC?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000048 elementor-widget elementor-widget-text-editor\" data-id=\"nr000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>No lo d\u00e9 por sentado. Los sistemas de CO2 tienen diferentes requisitos de presi\u00f3n y pueden necesitar diferentes tuber\u00edas, accesorios, v\u00e1lvulas y componentes de seguridad. Siga el dise\u00f1o aprobado del sistema de CO2 y los datos del equipo.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000049 elementor-widget elementor-widget-heading\" data-id=\"nr000049\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-i-send-for-a-refrigerant-piping-review\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 debo enviar para una revisi\u00f3n de las tuber\u00edas de refrigerante?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004a elementor-widget elementor-widget-text-editor\" data-id=\"nr00004a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Env\u00ede el esquema de tuber\u00edas, el refrigerante, la capacidad y las condiciones de operaci\u00f3n, los modelos de los componentes, las longitudes y elevaciones de las l\u00edneas, la disposici\u00f3n de los accesorios, la especificaci\u00f3n del material y los modos de operaci\u00f3n. Incluya la revisi\u00f3n del plano y anote qu\u00e9 valores est\u00e1n confirmados frente a los que a\u00fan est\u00e1n en revisi\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004b elementor-widget elementor-widget-heading\" data-id=\"nr00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"review-the-coil-and-piping-interface-before-release\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Revise la interfaz del serpent\u00edn y la tuber\u00eda antes de la liberaci\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004c elementor-widget elementor-widget-text-editor\" data-id=\"nr00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si su proyecto incluye un paquete personalizado de evaporador, condensador o unidad condensadora, env\u00ede el plano, el refrigerante, el objetivo de capacidad, las condiciones de operaci\u00f3n y el programa de conexiones de tuber\u00edas con la solicitud de cotizaci\u00f3n (RFQ). El equipo de Domi describe la revisi\u00f3n de planos y el soporte de ingenier\u00eda t\u00e9rmica para proyectos de intercambiadores de calor. Pida al equipo que confirme si la revisi\u00f3n de tuber\u00edas solicitada se encuentra dentro del alcance del proyecto.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004d elementor-widget elementor-widget-text-editor\" data-id=\"nr00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/capacidades-de-ingenieria\/\">Revise las capacidades de ingenier\u00eda de Domi<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004e elementor-align-left elementor-widget elementor-widget-button\" data-id=\"nr00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/es\/contacto\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Enviar una consulta de proyecto<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004f elementor-widget elementor-widget-heading\" data-id=\"nr00004f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-articles\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Art\u00edculos Relacionados<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005f e-con-full e-flex e-con e-parent\" data-id=\"nr00005f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000054 e-con-full e-flex e-con e-parent\" data-id=\"nr000054\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000051 e-con-full e-flex e-con e-parent\" data-id=\"nr000051\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000050 elementor-widget elementor-widget-text-editor\" data-id=\"nr000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/guia-de-seleccion-de-unidades-de-refrigeracion\/\">Gu\u00eda de selecci\u00f3n de unidades de refrigeraci\u00f3n para sistemas comerciales y OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000053 e-con-full e-flex e-con e-parent\" data-id=\"nr000053\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000052 elementor-widget elementor-widget-text-editor\" data-id=\"nr000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/compresor-de-refrigeracion\/\">Compresor de refrigeraci\u00f3n: Tipos, dimensionamiento y gu\u00eda de selecci\u00f3n OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000059 e-con-full e-flex e-con e-parent\" data-id=\"nr000059\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000056 e-con-full e-flex e-con e-parent\" data-id=\"nr000056\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000055 elementor-widget elementor-widget-text-editor\" data-id=\"nr000055\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/guia-de-controles-de-refrigeracion\/\">Gu\u00eda de controles de refrigeraci\u00f3n: tipos, funciones y datos para solicitudes de cotizaci\u00f3n (RFQ)<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000058 e-con-full e-flex e-con e-parent\" data-id=\"nr000058\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000057 elementor-widget elementor-widget-text-editor\" data-id=\"nr000057\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/ciclo-de-refrigerante\/\">Ciclo de refrigerante explicado: las 4 etapas y roles del serpent\u00edn<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005e e-con-full e-flex e-con e-parent\" data-id=\"nr00005e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr00005b e-con-full e-flex e-con e-parent\" data-id=\"nr00005b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00005a elementor-widget elementor-widget-text-editor\" data-id=\"nr00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/heat-pump-system-guide\/\">Gu\u00eda del sistema de bomba de calor para compradores OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005d e-con-full e-flex e-con e-parent\" data-id=\"nr00005d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00005c elementor-widget elementor-widget-text-editor\" data-id=\"nr00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/es\/product\/banco-de-compresores-de-refrigeracion-industrial-para-almacenamiento-en-frio\/\">Central de compresores de refrigeraci\u00f3n industrial para c\u00e1maras frigor\u00edficas<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Conozca las entradas para el dimensionamiento de las l\u00edneas de refrigerante, las comprobaciones de retorno de aceite por succi\u00f3n, los l\u00edmites de ca\u00edda de presi\u00f3n, el enrutamiento y lo que los compradores OEM deben incluir en una solicitud de cotizaci\u00f3n (RFQ) de tuber\u00edas.<\/p>","protected":false},"author":1,"featured_media":7135,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7147","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts\/7147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/comments?post=7147"}],"version-history":[{"count":3,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts\/7147\/revisions"}],"predecessor-version":[{"id":7150,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/posts\/7147\/revisions\/7150"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/media\/7135"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/media?parent=7147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/categories?post=7147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/es\/wp-json\/wp\/v2\/tags?post=7147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}