{"id":7070,"date":"2026-09-27T17:10:53","date_gmt":"2026-09-27T09:10:53","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7070"},"modified":"2026-09-27T17:10:53","modified_gmt":"2026-09-27T09:10:53","slug":"guide-de-la-vanne-dexpansion-thermostatique","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/fr\/thermostatic-expansion-valve-guide\/","title":{"rendered":"Guide sur le d\u00e9tendeur thermostatique : principe de fonctionnement, surchauffe, s\u00e9lection et donn\u00e9es pour demande de devis"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7070\" class=\"elementor elementor-7070\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00006b e-con-full e-flex e-con e-parent\" data-id=\"h00006b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000001 elementor-widget elementor-widget-image\" data-id=\"h000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero.webp\" class=\"attachment-full size-full wp-image-7059\" alt=\"Syst\u00e8me de r\u00e9frig\u00e9ration industrielle avec compresseur et serpentin de refroidissement dans un cadre commercial.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-hero-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : d\u00e9tendeur thermostatique install\u00e9 dans un circuit de r\u00e9frig\u00e9ration commercial avec \u00e9vaporateur, ampoule de d\u00e9tection, \u00e9galiseur et ligne liquide.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000002 elementor-widget elementor-widget-text-editor\" data-id=\"h000002\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Un d\u00e9tendeur thermostatique (DT) dose le r\u00e9frig\u00e9rant liquide dans un \u00e9vaporateur \u00e0 expansion directe en r\u00e9agissant \u00e0 la surchauffe \u00e0 la sortie de l'\u00e9vaporateur.<\/strong> La vanne \u00e9quilibre la pression de l\u2019ampoule de d\u00e9tection, la pression de l\u2019\u00e9vaporateur et la force du ressort afin que l\u2019\u00e9vaporateur re\u00e7oive suffisamment de r\u00e9frig\u00e9rant pour la charge actuelle, tandis que la vapeur quitte la sortie avant d\u2019atteindre le compresseur. Une s\u00e9lection correcte du DT n\u00e9cessite plus que la taille du tuyau : confirmer le r\u00e9frig\u00e9rant, la capacit\u00e9, la temp\u00e9rature d\u2019\u00e9vaporation, la condition de condensation, la perte de pression, la m\u00e9thode d\u2019\u00e9galisation, l\u2019agencement du distributeur, la charge de l\u2019ampoule, le type de connexion et l\u2019objectif de surchauffe lors de la mise en service.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000003 elementor-widget elementor-widget-text-editor\" data-id=\"h000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ce guide est destin\u00e9 aux ing\u00e9nieurs en r\u00e9frig\u00e9ration, acheteurs OEM, entrepreneurs, distributeurs et \u00e9quipes de projet comparant une nouvelle vanne ou un remplacement. Il s\u00e9pare le principe de fonctionnement des d\u00e9cisions de s\u00e9lection et d\u2019installation qui d\u00e9terminent si la vanne contr\u00f4lera de fa\u00e7on stable dans le syst\u00e8me final.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000004 elementor-widget elementor-widget-heading\" data-id=\"h000004\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-a-thermostatic-expansion-valve-does\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ce que fait un d\u00e9tendeur thermostatique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000005 elementor-widget elementor-widget-text-editor\" data-id=\"h000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un DT est un dispositif de r\u00e9gulation et de dosage entre la ligne liquide et l\u2019\u00e9vaporateur. Il cr\u00e9e une chute de pression, abaisse la temp\u00e9rature de saturation du r\u00e9frig\u00e9rant et r\u00e9gule le d\u00e9bit massique dans l\u2019\u00e9vaporateur. La vanne r\u00e9agit \u00e0 la condition \u00e0 la sortie de l\u2019\u00e9vaporateur plut\u00f4t que de simplement s\u2019ouvrir selon un pourcentage fixe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000006 elementor-widget elementor-widget-text-editor\" data-id=\"h000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant des d\u00e9tendeurs thermostatiques 1\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Question de l'acheteur<\/th>\n<th>R\u00e9ponse pratique sur le DT<\/th>\n<th>Pourquoi cela compte dans une demande de devis<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Que contr\u00f4le-t-il ?<\/td>\n<td>D\u00e9bit massique de r\u00e9frig\u00e9rant dans un \u00e9vaporateur \u00e0 expansion directe<\/td>\n<td>La vanne doit correspondre \u00e0 la charge, au r\u00e9frig\u00e9rant et aux temp\u00e9ratures de fonctionnement<\/td>\n<\/tr>\n<tr>\n<td>Quel signal utilise-t-elle ?<\/td>\n<td>Temp\u00e9rature de sortie et pression de l\u2019\u00e9vaporateur, exprim\u00e9es en surchauffe<\/td>\n<td>L\u2019emplacement de l\u2019ampoule de d\u00e9tection et de l\u2019\u00e9galiseur doit \u00eatre d\u00e9fini<\/td>\n<\/tr>\n<tr>\n<td>Contre quoi prot\u00e8ge-t-elle ?<\/td>\n<td>Retour de liquide lorsqu\u2019elle est appliqu\u00e9e et r\u00e9gl\u00e9e correctement<\/td>\n<td>Un mauvais contact de l\u2019ampoule, une charge incorrecte ou une suralimentation peuvent toujours endommager un compresseur<\/td>\n<\/tr>\n<tr>\n<td>Est-elle fixe ou modulante ?<\/td>\n<td>Elle module l\u2019ouverture selon la charge et la surchauffe<\/td>\n<td>Des donn\u00e9es de capacit\u00e9 et de perte de charge sont n\u00e9cessaires pour un contr\u00f4le stable<\/td>\n<\/tr>\n<tr>\n<td>O\u00f9 est-il install\u00e9 ?<\/td>\n<td>Dans l\u2019alimentation en liquide pr\u00e8s de l\u2019entr\u00e9e de l\u2019\u00e9vaporateur<\/td>\n<td>La disposition du r\u00e9partiteur et l\u2019acc\u00e8s pour la maintenance influencent l\u2019installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000007 elementor-widget elementor-widget-text-editor\" data-id=\"h000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le mot \u201c thermostatique \u201d fait r\u00e9f\u00e9rence \u00e0 l\u2019\u00e9l\u00e9ment sensible \u00e0 la temp\u00e9rature, et non \u00e0 un thermostat d\u2019ambiance. Un d\u00e9tendeur thermostatique (DT) ne r\u00e8gle pas directement la temp\u00e9rature de la pi\u00e8ce, la gestion des compresseurs ou le d\u00e9givrage. Ces fonctions rel\u00e8vent du syst\u00e8me de r\u00e9gulation frigorifique global. Pour cette limite, voir le <a href=\"https:\/\/domirefrigeration.com\/fr\/guide-des-commandes-de-refrigeration\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">guide des commandes de r\u00e9frig\u00e9ration<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000008 elementor-widget elementor-widget-heading\" data-id=\"h000008\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-a-thermostatic-expansion-valve-works\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment fonctionne un d\u00e9tendeur thermostatique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000009 elementor-widget elementor-widget-image\" data-id=\"h000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance.webp\" class=\"attachment-full size-full wp-image-7058\" alt=\"Vue \u00e9clat\u00e9e d&#039;une vanne de r\u00e9frig\u00e9ration montrant les composants internes et les circuits d&#039;\u00e9coulement.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-pressure-balance-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : coupe d\u2019un d\u00e9tendeur thermostatique montrant la membrane, l\u2019\u00e9l\u00e9ment moteur, le ressort, l\u2019orifice et le trajet du fluide frigorig\u00e8ne.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000a elementor-widget elementor-widget-text-editor\" data-id=\"h00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La vanne comprend un \u00e9l\u00e9ment moteur, une ampoule de d\u00e9tection, un tube capillaire, une membrane, un ressort, un si\u00e8ge de vanne, un orifice et un passage ou raccord \u00e9galiseur. En r\u00e9gime stable, trois forces principales s\u2019\u00e9quilibrent :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000b elementor-widget elementor-widget-text-editor\" data-id=\"h00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant des d\u00e9tendeurs thermostatiques 2\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Force<\/th>\n<th>Source<\/th>\n<th>Direction sur la membrane<\/th>\n<th>Effet de fonctionnement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Pression de l\u2019ampoule<\/td>\n<td>Le fluide dans l\u2019ampoule de d\u00e9tection r\u00e9agit \u00e0 la temp\u00e9rature de la ligne d\u2019aspiration<\/td>\n<td>Ouvre la vanne<\/td>\n<td>Une temp\u00e9rature d\u00e9tect\u00e9e plus \u00e9lev\u00e9e augmente g\u00e9n\u00e9ralement la force d\u2019ouverture<\/td>\n<\/tr>\n<tr>\n<td>Pression de l\u2019\u00e9vaporateur<\/td>\n<td>Pression transmise par un \u00e9galiseur interne ou externe<\/td>\n<td>Ferme la vanne<\/td>\n<td>Varie selon la pression d\u2019\u00e9vaporation et la perte de charge \u00e0 travers l\u2019\u00e9vaporateur<\/td>\n<\/tr>\n<tr>\n<td>Pression du ressort<\/td>\n<td>Ressort de r\u00e9glage de surchauffe<\/td>\n<td>Ferme la vanne<\/td>\n<td>\u00c9tablit la partie statique du r\u00e9glage de la surchauffe<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000c elementor-widget elementor-widget-text-editor\" data-id=\"h00000c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019\u00e9quilibre simplifi\u00e9 est <strong>pression du bulbe = pression de l\u2019\u00e9vaporateur + force du ressort<\/strong>. Lorsque la charge augmente, la sortie de l\u2019\u00e9vaporateur tend \u00e0 devenir plus chaude et la pression du bulbe augmente. La membrane se d\u00e9place vers l\u2019ouverture, laissant entrer plus de liquide. Lorsque la sortie refroidit et que la surchauffe diminue, les forces de fermeture r\u00e9tablissent l\u2019\u00e9quilibre et la vanne r\u00e9duit le d\u00e9bit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000d elementor-widget elementor-widget-text-editor\" data-id=\"h00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cette r\u00e9ponse explique pourquoi un d\u00e9tendeur thermostatique peut suivre les variations de charge plus efficacement qu\u2019un orifice fixe. Cela ne signifie pas que la vanne peut corriger tous les probl\u00e8mes du syst\u00e8me. Une ligne liquide affam\u00e9e, un filtre-d\u00e9shydrateur obstru\u00e9, un sous-refroidissement insuffisant, une charge de r\u00e9frig\u00e9rant incorrecte, un mauvais d\u00e9bit d\u2019air ou un bulbe mal install\u00e9 peuvent tous appara\u00eetre comme un probl\u00e8me de d\u00e9tente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000e elementor-widget elementor-widget-text-editor\" data-id=\"h00000e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/R26\/SI\/r26_ch11\/r26_ch11_si.aspx\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Chapitre sur les dispositifs de r\u00e9gulation du froid de l\u2019ASHRAE<\/a> d\u00e9crit le m\u00eame \u00e9quilibre de pression et distingue la surchauffe statique, d\u2019ouverture et de fonctionnement. Le <a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/how-thermostatic-expansion-valves-work\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">explication du d\u00e9tendeur thermostatique Danfoss<\/a> est \u00e9galement utile lors de la formation des \u00e9quipes d\u2019installation et de maintenance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00000f elementor-widget elementor-widget-heading\" data-id=\"h00000f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"superheat-the-control-variable-buyers-must-define\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Surchauffe : la variable de contr\u00f4le que les acheteurs doivent d\u00e9finir<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000010 elementor-widget elementor-widget-image\" data-id=\"h000010\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement.webp\" class=\"attachment-full size-full wp-image-7057\" alt=\"Technicien inspectant un syst\u00e8me de r\u00e9frig\u00e9ration industriel avec des manom\u00e8tres et des outils.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-superheat-measurement-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration du concept : technicien frigoriste asiatique mesurant la pression d\u2019aspiration et la temp\u00e9rature de sortie pour calculer la surchauffe de l\u2019\u00e9vaporateur.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000011 elementor-widget elementor-widget-text-editor\" data-id=\"h000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La surchauffe est la diff\u00e9rence entre la temp\u00e9rature r\u00e9elle de la vapeur \u00e0 un point de mesure et la temp\u00e9rature de saturation du r\u00e9frig\u00e9rant correspondant \u00e0 la pression mesur\u00e9e \u00e0 ce point. Sur un syst\u00e8me \u00e0 d\u00e9tendeur thermostatique, les techniciens \u00e9valuent normalement la surchauffe de sortie de l\u2019\u00e9vaporateur ou la surchauffe totale d\u2019aspiration selon la conception de l\u2019\u00e9quipement et la proc\u00e9dure du fabricant.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000012 elementor-widget elementor-widget-text-editor\" data-id=\"h000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 3\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Terme<\/th>\n<th>Signification<\/th>\n<th>Utilisation lors de la s\u00e9lection ou de la mise en service<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Surchauffe statique<\/td>\n<td>Surchauffe \u00e0 laquelle la vanne commence \u00e0 s\u2019ouvrir<\/td>\n<td>Fait partie du r\u00e9glage d\u2019usine et du choix du ressort<\/td>\n<\/tr>\n<tr>\n<td>Surchauffe d\u2019ouverture<\/td>\n<td>Surchauffe suppl\u00e9mentaire n\u00e9cessaire pour ouvrir la vanne \u00e0 une position utile<\/td>\n<td>Utilis\u00e9 dans les \u00e9valuations de capacit\u00e9 du fabricant<\/td>\n<\/tr>\n<tr>\n<td>Surchauffe de fonctionnement<\/td>\n<td>Surchauffe statique plus surchauffe d\u2019ouverture \u00e0 la charge de travail<\/td>\n<td>La valeur sur site utilis\u00e9e pour \u00e9valuer le risque d\u2019alimentation et de retour de liquide<\/td>\n<\/tr>\n<tr>\n<td>Surchauffe \u00e0 la sortie de l\u2019\u00e9vaporateur<\/td>\n<td>\u00c9l\u00e9vation de temp\u00e9rature au-dessus de la saturation \u00e0 la sortie de l\u2019\u00e9vaporateur<\/td>\n<td>Aide \u00e0 confirmer que l\u2019\u00e9vaporateur est aliment\u00e9 sans retour de liquide<\/td>\n<\/tr>\n<tr>\n<td>Surchauffe totale \u00e0 l\u2019aspiration<\/td>\n<td>Surchauffe \u00e0 la sortie plus chaleur absorb\u00e9e dans la ligne d\u2019aspiration<\/td>\n<td>Utile pour la protection de l\u2019entr\u00e9e du compresseur, mais ne pas confondre avec la surchauffe \u00e0 la sortie de l\u2019\u00e9vaporateur<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000013 elementor-widget elementor-widget-text-editor\" data-id=\"h000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La cible exacte d\u00e9pend du fluide frigorig\u00e8ne, du design de l\u2019\u00e9vaporateur, de la charge, du r\u00e9partiteur, des exigences du compresseur et des instructions du fabricant de l\u2019\u00e9quipement. \u00c9vitez d\u2019ins\u00e9rer un chiffre universel dans un appel d\u2019offres lorsque les conditions du syst\u00e8me ne sont pas connues. Une vanne s\u00e9lectionn\u00e9e sur la \u201c capacit\u00e9 de r\u00e9serve maximale \u201d peut fonctionner \u00e0 une surchauffe ind\u00e9sirable et moduler mal \u00e0 faible charge.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000014 elementor-widget elementor-widget-heading\" data-id=\"h000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"sensing-bulb-and-equalizer-arrangement\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Disposition du bulbe de d\u00e9tection et de l\u2019\u00e9galiseur<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000015 elementor-widget elementor-widget-image\" data-id=\"h000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation.webp\" class=\"attachment-full size-full wp-image-7060\" alt=\"Gros plan sur la tuyauterie en cuivre et l&#039;isolation d&#039;un syst\u00e8me de refroidissement commercial.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-bulb-installation-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : Bulbe de d\u00e9tection de vanne d\u2019expansion thermostatique fix\u00e9 sur une ligne d\u2019aspiration horizontale propre avec isolation et \u00e9galiseur externe.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000016 elementor-widget elementor-widget-text-editor\" data-id=\"h000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le bulbe de d\u00e9tection est l\u2019entr\u00e9e de temp\u00e9rature de la vanne. Il se trouve normalement sur la ligne d\u2019aspiration \u00e0 la sortie de l\u2019\u00e9vaporateur, o\u00f9 il peut mesurer une temp\u00e9rature repr\u00e9sentative de la vapeur. La ligne doit \u00eatre propre, le bulbe doit avoir un contact thermique ferme, et la pince doit \u00eatre adapt\u00e9e au diam\u00e8tre du tube. Une isolation peut \u00eatre n\u00e9cessaire lorsque l\u2019air ambiant pourrait fausser la lecture.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000017 elementor-widget elementor-widget-text-editor\" data-id=\"h000017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019emplacement du bulbe fait partie de la conception du contr\u00f4le. S\u2019il est trop proche d\u2019une source de chaleur, plac\u00e9 l\u00e0 o\u00f9 du liquide peut s\u2019accumuler, mont\u00e9 sur une section peu repr\u00e9sentative ou laiss\u00e9 l\u00e2che, le d\u00e9tendeur thermostatique peut osciller, sous-alimenter ou suralimenter. L\u2019installateur doit suivre l\u2019orientation et la position du bulbe autoris\u00e9es par le fabricant de la vanne pour le diam\u00e8tre r\u00e9el du tuyau et le fluide frigorig\u00e8ne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000018 elementor-widget elementor-widget-image\" data-id=\"h000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer.webp\" class=\"attachment-full size-full wp-image-7061\" alt=\"Chemins d\u2019\u00e9galisation interne et externe sur un circuit de d\u00e9tendeur thermostatique avec un \u00e9vaporateur \u00e0 circuits multiples\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-equalizer-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : Chemins d\u2019\u00e9galisation interne et externe sur un circuit de vanne d\u2019expansion thermostatique avec un \u00e9vaporateur \u00e0 circuits multiples.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000019 elementor-widget elementor-widget-text-editor\" data-id=\"h000019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L\u2019\u00e9galisation interne prend la pression de l\u2019\u00e9vaporateur via un passage dans le corps de la vanne. L\u2019\u00e9galisation externe utilise une ligne s\u00e9par\u00e9e connect\u00e9e \u00e0 la sortie de l\u2019\u00e9vaporateur ou \u00e0 un autre point de pression sp\u00e9cifi\u00e9. L\u2019\u00e9galisation externe est souvent requise lorsque l\u2019\u00e9vaporateur, le r\u00e9partiteur ou le chemin d\u2019aspiration cr\u00e9e une chute de pression significative. La s\u00e9lection doit \u00eatre confirm\u00e9e selon la conception du circuit d\u2019\u00e9vaporateur et non d\u00e9duite de la taille de la connexion.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001a elementor-widget elementor-widget-text-editor\" data-id=\"h00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 4\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Agencement<\/th>\n<th>Point de d\u00e9part appropri\u00e9<\/th>\n<th>Questions \u00e0 confirmer<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u00c9galiseur interne<\/td>\n<td>\u00c9vaporateur compact \u00e0 circuit unique avec perte de charge interne limit\u00e9e<\/td>\n<td>La pression \u00e0 la sortie de la vanne est-elle repr\u00e9sentative de la sortie de l'\u00e9vaporateur ?<\/td>\n<\/tr>\n<tr>\n<td>\u00c9galiseur externe<\/td>\n<td>\u00c9vaporateur \u00e0 circuits multiples, r\u00e9partiteur ou perte de charge plus \u00e9lev\u00e9e<\/td>\n<td>O\u00f9 l\u2019\u00e9galiseur doit-il \u00eatre raccord\u00e9 et un piquage ou raccord de pression est-il inclus ?<\/td>\n<\/tr>\n<tr>\n<td>\u00c9galiseur externe avec r\u00e9partiteur<\/td>\n<td>Syst\u00e8mes o\u00f9 la perte de pression de distribution influence le point de r\u00e9gulation<\/td>\n<td>La capacit\u00e9 de la vanne s\u00e9lectionn\u00e9e tient-elle compte de la perte de pression du r\u00e9partiteur ?<\/td>\n<\/tr>\n<tr>\n<td>Emplacement du bulbe distant ou inhabituel<\/td>\n<td>\u00c9quipement avec acheminement d\u2019aspiration sp\u00e9cial ou \u00e9changeurs de chaleur<\/td>\n<td>Le fabricant approuve-t-il le point de d\u00e9tection et la charge pour cette configuration ?<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001b elementor-widget elementor-widget-heading\" data-id=\"h00001b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"txv-types-and-when-to-compare-them\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Types de d\u00e9tendeurs thermostatiques et quand les comparer<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001c elementor-widget elementor-widget-image\" data-id=\"h00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types.webp\" class=\"attachment-full size-full wp-image-7062\" alt=\"Collection de vannes de r\u00e9frig\u00e9ration industrielles sur un \u00e9tabli chez Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-types-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : comparaison des d\u00e9tendeurs thermostatiques \u00e0 \u00e9galisation interne, \u00e0 \u00e9galisation externe, \u00e0 orifice \u00e9quilibr\u00e9 et \u00e0 orifice rempla\u00e7able.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001d elementor-widget elementor-widget-text-editor\" data-id=\"h00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diff\u00e9rents d\u00e9tendeurs thermostatiques peuvent sembler similaires tout en ayant un comportement de r\u00e9gulation diff\u00e9rent. Comparez la construction interne et la classification d\u2019application, pas seulement les raccordements d\u2019entr\u00e9e et de sortie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001e elementor-widget elementor-widget-text-editor\" data-id=\"h00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 5\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Type ou caract\u00e9ristique du d\u00e9tendeur thermostatique<\/th>\n<th>Ce qui change<\/th>\n<th>O\u00f9 cela peut \u00eatre utile<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u00c0 \u00e9galisation interne<\/td>\n<td>La pression de l\u2019\u00e9vaporateur est mesur\u00e9e \u00e0 travers le corps de la vanne<\/td>\n<td>Circuits simples avec faible perte de charge<\/td>\n<\/tr>\n<tr>\n<td>\u00c0 \u00e9galisation externe<\/td>\n<td>Un \u00e9galiseur d\u00e9di\u00e9 d\u00e9tecte la pression au point aval sp\u00e9cifi\u00e9<\/td>\n<td>Applications avec \u00e9vaporateurs \u00e0 circuits multiples et distributeurs<\/td>\n<\/tr>\n<tr>\n<td>Orifice conventionnel<\/td>\n<td>Les forces sur l\u2019orifice varient selon les conditions de pression dans la vanne<\/td>\n<td>Applications plus petites ou moins exigeantes lorsque la classification du fabricant le permet<\/td>\n<\/tr>\n<tr>\n<td>Orifice \u00e9quilibr\u00e9<\/td>\n<td>La conception de l\u2019orifice r\u00e9duit l\u2019effet de la variation de pression d\u2019entr\u00e9e sur la force d\u2019ouverture<\/td>\n<td>Capacit\u00e9 sup\u00e9rieure ou conditions de pression variable lorsque sp\u00e9cifi\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Charge universelle du bulbe<\/td>\n<td>R\u00e9ponse de fonctionnement \u00e9tendue sur une plage de temp\u00e9rature d\u00e9finie<\/td>\n<td>Applications g\u00e9n\u00e9rales dans l\u2019enveloppe du fabricant de la charge<\/td>\n<\/tr>\n<tr>\n<td>Charge anti-chasse ou s\u00e9lective<\/td>\n<td>L\u2019amortissement ou une r\u00e9ponse pression-temp\u00e9rature s\u00e9lectionn\u00e9e modifie la modulation<\/td>\n<td>Syst\u00e8mes o\u00f9 la chasse ou une plage de fonctionnement \u00e9troite pose probl\u00e8me<\/td>\n<\/tr>\n<tr>\n<td>Orifice interchangeable<\/td>\n<td>Le corps et la capacit\u00e9 de dosage peuvent \u00eatre adapt\u00e9s avec un insert<\/td>\n<td>Stock de service et plages de capacit\u00e9 s\u00e9lectionn\u00e9es, si approuv\u00e9es par le fabricant<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00001f elementor-widget elementor-widget-text-editor\" data-id=\"h00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/walk-in-coolers-thermostatic-expansion-valves-and-solenoid-valves\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Explication Danfoss pour chambre froide<\/a> explique comment le bulbe, le diaphragme, l\u2019\u00e9galiseur et le ressort fonctionnent ensemble. Pour une conception commerciale ou industrielle r\u00e9parable, indiquez \u00e9galement si l\u2019\u00e9l\u00e9ment de puissance, le corps, l\u2019orifice et les raccords sont rempla\u00e7ables en tant que pi\u00e8ces s\u00e9par\u00e9es.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000020 elementor-widget elementor-widget-heading\" data-id=\"h000020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"txv-selection-inputs-for-a-refrigeration-project\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Entr\u00e9es de s\u00e9lection TXV pour un projet de r\u00e9frig\u00e9ration<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000021 elementor-widget elementor-widget-image\" data-id=\"h000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs.webp\" class=\"attachment-full size-full wp-image-7063\" alt=\"Ing\u00e9nieur analysant les donn\u00e9es d&#039;un syst\u00e8me de r\u00e9frig\u00e9ration dans l&#039;installation de Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-selection-inputs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : ing\u00e9nieur HVACR asiatique examinant le r\u00e9frig\u00e9rant, la capacit\u00e9, la temp\u00e9rature d'\u00e9vaporation, la perte de pression et les param\u00e8tres de s\u00e9lection du d\u00e9tendeur thermostatique (TXV).<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000022 elementor-widget elementor-widget-text-editor\" data-id=\"h000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un fabricant ou un distributeur en France doit pouvoir reproduire la s\u00e9lection \u00e0 partir des informations fournies dans la demande de devis (RFQ). Fournissez les points de fonctionnement plut\u00f4t que seulement la puissance nominale ou le diam\u00e8tre du tuyau.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000023 elementor-widget elementor-widget-text-editor\" data-id=\"h000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 6\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Donn\u00e9e d'entr\u00e9e pour la s\u00e9lection<\/th>\n<th>Informations minimales \u00e0 fournir<\/th>\n<th>Pourquoi le fournisseur de valves en a besoin<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Fluide frigorig\u00e8ne<\/td>\n<td>D\u00e9signation exacte du r\u00e9frig\u00e9rant et statut du m\u00e9lange ou de la conversion<\/td>\n<td>La capacit\u00e9, le comportement pression-temp\u00e9rature, la charge du bulbe et les mat\u00e9riaux en d\u00e9pendent<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9 frigorifique<\/td>\n<td>Capacit\u00e9 requise \u00e0 la condition d'\u00e9vaporation de conception<\/td>\n<td>La valve doit alimenter la charge sans d\u00e9pendre d'une capacit\u00e9 de r\u00e9serve non approuv\u00e9e<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature d'\u00e9vaporation<\/td>\n<td>Plage de conception et de fonctionnement attendue<\/td>\n<td>D\u00e9termine la pression, le comportement de surchauffe et la classification de la valve<\/td>\n<\/tr>\n<tr>\n<td>Condition de condensation<\/td>\n<td>Plage de temp\u00e9rature ou de pression de condensation de conception<\/td>\n<td>Affecte la perte de pression disponible et la stabilit\u00e9 de l'alimentation en liquide<\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature du liquide et sous-refroidissement<\/td>\n<td>Temp\u00e9rature \u00e0 l'entr\u00e9e de la valve et sous-refroidissement du liquide disponible<\/td>\n<td>Confirme que le liquide atteint le dispositif de dosage sans gaz flash<\/td>\n<\/tr>\n<tr>\n<td>Perte de charge<\/td>\n<td>Perte de pression disponible \u00e0 travers la valve au point de conception<\/td>\n<td>Les tableaux de capacit\u00e9 sont li\u00e9s \u00e0 la perte de pression, et non seulement au diam\u00e8tre de connexion<\/td>\n<\/tr>\n<tr>\n<td>Circuit d'\u00e9vaporateur<\/td>\n<td>Circuit simple ou multiple, type de distributeur et perte de pression<\/td>\n<td>D\u00e9termine l'agencement de l'\u00e9galiseur et la compatibilit\u00e9 du distributeur<\/td>\n<\/tr>\n<tr>\n<td>Charge du bulbe et surchauffe<\/td>\n<td>Charge familiale requise et r\u00e9glage initial ou d'usine<\/td>\n<td>Contr\u00f4le la plage de r\u00e9ponse et le comportement en faible charge<\/td>\n<\/tr>\n<tr>\n<td>Connexions<\/td>\n<td>Taille de l'entr\u00e9e\/sortie, mat\u00e9riau du tube, raccordement par \u00e9vasement\/brasure ou autre<\/td>\n<td>Emp\u00eache qu'une correspondance dimensionnelle masque un d\u00e9saccord de d\u00e9bit ou d'installation<\/td>\n<\/tr>\n<tr>\n<td>Ambiance et service<\/td>\n<td>Local, proc\u00e9d\u00e9, abaissement rapide, charge de maintien et plage de modulation<\/td>\n<td>Indique si la vanne doit moduler sur une large plage de charges<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000024 elementor-widget elementor-widget-text-editor\" data-id=\"h000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ne dimensionnez pas un d\u00e9tendeur thermostatique (TXV) uniquement selon le d\u00e9placement du compresseur. La vanne tient compte de la charge de l'\u00e9vaporateur et des conditions de pression. Si l'\u00e9quipement fonctionne selon plusieurs modes, listez chaque mode et demandez au fournisseur de v\u00e9rifier l'orifice et la capacit\u00e9 s\u00e9lectionn\u00e9s sur toute la plage de fonctionnement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000025 elementor-widget elementor-widget-heading\" data-id=\"h000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"matching-txv-capacity-to-pressure-drop-and-load\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Adapter la capacit\u00e9 du TXV \u00e0 la chute de pression et \u00e0 la charge<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000026 elementor-widget elementor-widget-image\" data-id=\"h000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications.webp\" class=\"attachment-full size-full wp-image-7064\" alt=\"Syst\u00e8me de r\u00e9frig\u00e9ration industriel comprenant des compresseurs, des \u00e9changeurs de chaleur et de la tuyauterie.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-applications-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : Application de r\u00e9frig\u00e9ration montrant la ligne liquide, le TXV, le r\u00e9partiteur, l'\u00e9vaporateur, la ligne d'aspiration, le compresseur et le condenseur.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000027 elementor-widget elementor-widget-text-editor\" data-id=\"h000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les tableaux de capacit\u00e9 varient g\u00e9n\u00e9ralement selon le fluide frigorig\u00e8ne, la temp\u00e9rature d'\u00e9vaporation, la condition de condensation ou d'entr\u00e9e, et la chute de pression. Une vanne qui semble suffisamment grande \u00e0 un point de fonctionnement peut \u00eatre instable \u00e0 un autre. Une vanne trop petite peut affamer l'\u00e9vaporateur \u00e0 la charge maximale ; une vanne trop grande peut perdre en pr\u00e9cision et osciller \u00e0 charge partielle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000028 elementor-widget elementor-widget-text-editor\" data-id=\"h000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilisez cette s\u00e9quence lors de la comparaison des s\u00e9lections du catalogue :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000029 elementor-widget elementor-widget-text-editor\" data-id=\"h000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li>Indiquez la capacit\u00e9 de conception et la plage de capacit\u00e9, y compris l'abaissement rapide et la charge de maintien minimale.<\/li>\n<li>D\u00e9terminez la temp\u00e9rature et la pression du liquide disponibles \u00e0 l'entr\u00e9e de la vanne.<\/li>\n<li>Calculez ou obtenez la chute de pression disponible \u00e0 travers la vanne apr\u00e8s avoir pris en compte les pertes dans la tuyauterie, l'\u00e9lectrovanne, le r\u00e9partiteur et les raccords.<\/li>\n<li>Utilisez le tableau de capacit\u00e9 ou l'outil de s\u00e9lection du fabricant pour le fluide frigorig\u00e8ne exact et la condition d'\u00e9vaporation.<\/li>\n<li>V\u00e9rifiez la vanne s\u00e9lectionn\u00e9e aux points de fonctionnement bas et haut, y compris la modulation.<\/li>\n<li>Confirmez que la vanne, l'orifice, la charge, l'\u00e9galiseur et le r\u00e9partiteur forment un ensemble assorti.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002a elementor-widget elementor-widget-text-editor\" data-id=\"h00002a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <a href=\"https:\/\/virtualengineer.parker.com\/myprojects\/Sizing\/Sizing?WFID=3f133247-cf7d-f011-b481-000d3a7abe26\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Outil de s\u00e9lection Parker Sporlan Virtual Engineer<\/a> illustre pourquoi la s\u00e9lection n\u00e9cessite des donn\u00e9es d'application. Consid\u00e9rez tout r\u00e9sultat de catalogue comme une s\u00e9lection de d\u00e9part jusqu'\u00e0 ce que le fournisseur confirme la plage de fonctionnement finale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002b elementor-widget elementor-widget-heading\" data-id=\"h00002b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"refrigerant-bulb-charge-and-material-compatibility\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9frig\u00e9rant, charge du bulbe et compatibilit\u00e9 des mat\u00e9riaux<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002c elementor-widget elementor-widget-text-editor\" data-id=\"h00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le r\u00e9frig\u00e9rant influence le comportement pression-temp\u00e9rature, la capacit\u00e9, les mat\u00e9riaux requis et la r\u00e9ponse de l\u2019\u00e9l\u00e9ment thermostatique. Il faut v\u00e9rifier la compatibilit\u00e9 de la vanne de remplacement avec le r\u00e9frig\u00e9rant r\u00e9el du circuit, y compris en cas de conversion ou de changement de m\u00e9lange. \u201c M\u00eame connexion \u201d n\u2019est pas une preuve de compatibilit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002d elementor-widget elementor-widget-text-editor\" data-id=\"h00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Confirmez ces \u00e9l\u00e9ments dans la soumission technique :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002e elementor-widget elementor-widget-text-editor\" data-id=\"h00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>D\u00e9signation du r\u00e9frig\u00e9rant et si le syst\u00e8me a \u00e9t\u00e9 converti \u00e0 partir d\u2019un autre r\u00e9frig\u00e9rant.<\/li>\n<li>Charge de bulbe ou \u00e9l\u00e9ment de puissance approuv\u00e9 pour la plage de temp\u00e9rature d\u2019\u00e9vaporation.<\/li>\n<li>Compatibilit\u00e9 du corps de vanne, du si\u00e8ge, du diaphragme, des joints et du joint d\u2019\u00e9tanch\u00e9it\u00e9.<\/li>\n<li>Pression nominale et pression de service admissible pour les c\u00f4t\u00e9s haute et basse pression.<\/li>\n<li>Conditions d\u2019huile et de contamination, surtout apr\u00e8s une panne ou un br\u00fblage du compresseur.<\/li>\n<li>Si la vanne n\u00e9cessite un filtre-d\u00e9shydrateur, une cr\u00e9pine d\u2019entr\u00e9e ou une proc\u00e9dure de nettoyage en amont.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00002f elementor-widget elementor-widget-text-editor\" data-id=\"h00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/50825\/AX266348279899en-000101.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Notes de montage Danfoss<\/a> d\u00e9crivent l\u2019\u00e9quilibre de pression et le r\u00f4le du ressort dans le r\u00e9glage du surchauffe. Pour la s\u00e9lection finale, le catalogue actuel du fabricant de la vanne et les donn\u00e9es d\u2019application font foi.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000030 elementor-widget elementor-widget-heading\" data-id=\"h000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"common-txv-symptoms-and-diagnostic-order\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Sympt\u00f4mes courants du d\u00e9tendeur thermostatique (TXV) et ordre de diagnostic<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000031 elementor-widget elementor-widget-image\" data-id=\"h000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms.webp\" class=\"attachment-full size-full wp-image-7065\" alt=\"Technicien inspectant une unit\u00e9 de r\u00e9frig\u00e9ration commerciale avec des outils de diagnostic.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-symptoms-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : technicien de service asiatique diagnostiquant un syst\u00e8me de r\u00e9frig\u00e9ration avec manom\u00e8tres, sondes, givre sur l\u2019\u00e9vaporateur, filtre-d\u00e9shydrateur et TXV.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000032 elementor-widget elementor-widget-text-editor\" data-id=\"h000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un sympt\u00f4me du syst\u00e8me prouve rarement que le TXV lui-m\u00eame est d\u00e9fectueux. Utilisez un ordre de diagnostic fixe afin qu\u2019une ligne liquide bloqu\u00e9e ou une charge incorrecte ne soit pas confondue avec une vanne d\u00e9fectueuse.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000033 elementor-widget elementor-widget-text-editor\" data-id=\"h000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 7\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Sympt\u00f4me observ\u00e9<\/th>\n<th>Causes possibles du TXV ou du syst\u00e8me<\/th>\n<th>V\u00e9rifications avant remplacement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Faible capacit\u00e9 de l\u2019\u00e9vaporateur et surchauffe \u00e9lev\u00e9e \u00e0 la sortie<\/td>\n<td>Vanne affam\u00e9e, basse pression liquide, gaz flash, d\u00e9shydrateur bloqu\u00e9, charge faible, bulbe non d\u00e9tect\u00e9<\/td>\n<td>V\u00e9rifiez le sous-refroidissement du liquide, le voyant l\u00e0 o\u00f9 il est install\u00e9, la chute de pression, le contact du bulbe et l\u2019\u00e9galiseur<\/td>\n<\/tr>\n<tr>\n<td>Faible surchauffe ou risque de retour de liquide<\/td>\n<td>Suralimentation, charge de bulbe incorrecte, bulbe desserr\u00e9, r\u00e9glage incorrect, faible charge, probl\u00e8me de r\u00e9partiteur<\/td>\n<td>V\u00e9rifier le point de mesure, l'installation du bulbe, la charge, la charge de r\u00e9frig\u00e9rant et la protection du compresseur<\/td>\n<\/tr>\n<tr>\n<td>Instabilit\u00e9 de surchauffe<\/td>\n<td>Vanne surdimensionn\u00e9e, chute de pression instable, mauvais emplacement du bulbe, charge incompatible, alimentation liquide intermittente<\/td>\n<td>Enregistrer la surchauffe dans le temps et inspecter l\u2019\u00e9tat de l\u2019entr\u00e9e et les variations de charge<\/td>\n<\/tr>\n<tr>\n<td>Givre sur la vanne ou \u00e0 l\u2019entr\u00e9e<\/td>\n<td>Chute de pression et vaporisation, humidit\u00e9, restriction ou condition anormale c\u00f4t\u00e9 basse pression<\/td>\n<td>V\u00e9rifier le filtre-d\u00e9shydrateur, la temp\u00e9rature du liquide, les relev\u00e9s de pression et l\u2019\u00e9tat du r\u00e9frig\u00e9rant<\/td>\n<\/tr>\n<tr>\n<td>Aucune r\u00e9ponse au r\u00e9glage<\/td>\n<td>\u00c9l\u00e9ment moteur endommag\u00e9, pointeau gripp\u00e9, \u00e9galiseur bloqu\u00e9, mauvais sens de r\u00e9glage ou autre d\u00e9faut du syst\u00e8me<\/td>\n<td>Suivre la proc\u00e9dure du fabricant et v\u00e9rifier les instruments de pression et de temp\u00e9rature<\/td>\n<\/tr>\n<tr>\n<td>Fonctionne \u00e0 une charge mais \u00e9choue \u00e0 une autre<\/td>\n<td>Inad\u00e9quation de capacit\u00e9, de charge ou de chute de pression sur la plage de fonctionnement<\/td>\n<td>Rev\u00e9rifier les points de s\u00e9lection pour faible charge et charge maximale<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000034 elementor-widget elementor-widget-text-editor\" data-id=\"h000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ne tournez pas la tige de r\u00e9glage \u00e0 plusieurs reprises sans enregistrer la position d\u2019origine et attendre la stabilisation du syst\u00e8me. Une lecture pression-temp\u00e9rature prise \u00e0 un instant donn\u00e9 peut masquer une condition d\u2019instabilit\u00e9 ou intermittente. Si un compresseur a subi un retour de liquide ou une d\u00e9faillance, inclure des contr\u00f4les de l\u2019huile et de la propret\u00e9 du syst\u00e8me dans le plan de maintenance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000035 elementor-widget elementor-widget-heading\" data-id=\"h000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"installation-details-that-affect-txv-performance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">D\u00e9tails d\u2019installation affectant les performances du d\u00e9tendeur thermostatique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000036 elementor-widget elementor-widget-image\" data-id=\"h000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation.webp\" class=\"attachment-full size-full wp-image-7066\" alt=\"Syst\u00e8me de r\u00e9frig\u00e9ration industriel avec des tuyaux en cuivre et des unit\u00e9s de refroidissement chez Domi Refrigeration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-installation-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : Installation propre d\u2019un d\u00e9tendeur thermostatique pr\u00e8s d\u2019un \u00e9vaporateur avec une alimentation liquide courte, un r\u00e9partiteur et une tuyauterie support\u00e9e.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000037 elementor-widget elementor-widget-text-editor\" data-id=\"h000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Suivre la notice d\u2019installation du fabricant de la vanne et le sch\u00e9ma de l\u2019\u00e9quipement. La <a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Sporlan\/Sporlan-pdf-files\/Sporlan-pdf-010\/10-11.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Notice d\u2019installation Sporlan<\/a> met l\u2019accent sur l\u2019emplacement de la vanne, la proximit\u00e9 du r\u00e9partiteur, le support, et la bonne installation de l\u2019\u00e9galiseur et du bulbe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000038 elementor-widget elementor-widget-text-editor\" data-id=\"h000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les v\u00e9rifications d'installation doivent inclure :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000039 elementor-widget elementor-widget-text-editor\" data-id=\"h000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Montez la vanne aussi pr\u00e8s de l'\u00e9vaporateur que le permet la conception du circuit.<\/li>\n<li>Gardez la conduite entre la vanne et le r\u00e9partiteur courte et exempte de coudes ou de restrictions inutiles.<\/li>\n<li>Prot\u00e9gez le corps de la vanne et l'\u00e9l\u00e9ment de puissance contre une chaleur excessive lors du brasage.<\/li>\n<li>Installez le bulbe sur une surface propre et repr\u00e9sentative de la ligne d'aspiration avec la pince et l'orientation sp\u00e9cifi\u00e9es.<\/li>\n<li>Fixez et isolez le bulbe l\u00e0 o\u00f9 le fabricant ou la conception de l'\u00e9quipement l'exige.<\/li>\n<li>Dirigez l'\u00e9galiseur externe vers le point de pression sp\u00e9cifi\u00e9, sans restriction involontaire ni poche d'huile pi\u00e9g\u00e9e.<\/li>\n<li>Supportez les vannes et les tubes de plus grande taille afin que les vibrations ne sollicitent pas les joints.<\/li>\n<li>Emp\u00eachez l'humidit\u00e9, les d\u00e9bris, les r\u00e9sidus de brasage et l'exposition \u00e0 l'air libre d'entrer dans le circuit.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003a elementor-widget elementor-widget-text-editor\" data-id=\"h00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si une vanne \u00e9lectromagn\u00e9tique, une vanne manuelle, un r\u00e9partiteur, un accumulateur d'aspiration ou un \u00e9changeur de chaleur est plac\u00e9 autour du d\u00e9tendeur thermostatique, indiquez-le sur le sch\u00e9ma de tuyauterie et incluez sa perte de pression dans la revue de s\u00e9lection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003b elementor-widget elementor-widget-heading\" data-id=\"h00003b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"commissioning-and-superheat-verification\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Mise en service et v\u00e9rification du surchauffe<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003c elementor-widget elementor-widget-image\" data-id=\"h00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning.webp\" class=\"attachment-full size-full wp-image-7067\" alt=\"Ing\u00e9nieur de mise en service asiatique enregistrant la pression d\u2019aspiration, la temp\u00e9rature de la tuyauterie, la surchauffe et les conditions de charge sur une fiche de test de r\u00e9frig\u00e9ration\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-commissioning-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : Ing\u00e9nieur de mise en service asiatique enregistrant la pression d'aspiration, la temp\u00e9rature du tuyau, la surchauffe et les conditions de charge sur une fiche de test de r\u00e9frig\u00e9ration.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003d elementor-widget elementor-widget-text-editor\" data-id=\"h00003d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La mise en service doit \u00e9tablir une base stable avant d'ajuster le d\u00e9tendeur thermostatique. Enregistrez le fluide frigorig\u00e8ne, les conditions ext\u00e9rieures ou de l'usine, la charge de la pi\u00e8ce ou du proc\u00e9d\u00e9, les pressions de l'\u00e9vaporateur et d'aspiration, les temp\u00e9ratures pertinentes, l'\u00e9tat de la ligne liquide, le statut du compresseur et l'\u00e9tat du d\u00e9givrage.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003e elementor-widget elementor-widget-text-editor\" data-id=\"h00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 8\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>\u00c9tape de mise en service<\/th>\n<th>Enregistrement<\/th>\n<th>D\u00e9cision<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Confirmer le circuit<\/td>\n<td>Fluide frigorig\u00e8ne, mod\u00e8le de vanne, orifice, charge du bulbe, \u00e9galiseur et orientation de la tuyauterie<\/td>\n<td>Rejeter une incompatibilit\u00e9 avant l'ajustement<\/td>\n<\/tr>\n<tr>\n<td>Confirmer l'alimentation en liquide<\/td>\n<td>Temp\u00e9rature du liquide, sous-refroidissement, pression \u00e0 l'entr\u00e9e de la vanne et \u00e9tat du filtre-d\u00e9shydrateur<\/td>\n<td>Corriger d'abord le gaz flash ou la restriction<\/td>\n<\/tr>\n<tr>\n<td>Mesurer la sortie de l'\u00e9vaporateur<\/td>\n<td>Pression et temp\u00e9rature au point de mesure sp\u00e9cifi\u00e9<\/td>\n<td>Calculer la valeur de surchauffe pr\u00e9vue<\/td>\n<\/tr>\n<tr>\n<td>Observer la stabilit\u00e9<\/td>\n<td>Relev\u00e9s pendant la descente de temp\u00e9rature, le maintien et la charge minimale<\/td>\n<td>Identifier le pompage ou une mauvaise modulation<\/td>\n<\/tr>\n<tr>\n<td>V\u00e9rifier l'entr\u00e9e du compresseur<\/td>\n<td>Temp\u00e9rature d'aspiration, pression et limites du fabricant<\/td>\n<td>Confirmer que le compresseur est prot\u00e9g\u00e9<\/td>\n<\/tr>\n<tr>\n<td>N'ajuster que si n\u00e9cessaire<\/td>\n<td>Sens, quantit\u00e9, temps autoris\u00e9 pour la stabilisation et relev\u00e9s finaux<\/td>\n<td>Conserver un r\u00e9glage final tra\u00e7able<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00003f elementor-widget elementor-widget-text-editor\" data-id=\"h00003f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La mesure de la surchauffe n\u00e9cessite une lecture de pression convertie avec la bonne relation pression-temp\u00e9rature du fluide frigorig\u00e8ne et une mesure de temp\u00e9rature \u00e0 l'emplacement correct du tuyau. Ne comparez pas une temp\u00e9rature de la ligne d'aspiration situ\u00e9e \u00e0 plusieurs m\u00e8tres de l'\u00e9vaporateur avec une cible de sortie d'\u00e9vaporateur sans tenir compte du gain thermique de la ligne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000040 elementor-widget elementor-widget-heading\" data-id=\"h000040\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-to-include-in-a-txv-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Que doit contenir une demande de devis pour un d\u00e9tendeur thermostatique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000041 elementor-widget elementor-widget-image\" data-id=\"h000041\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq.webp\" class=\"attachment-full size-full wp-image-7068\" alt=\"Deux ing\u00e9nieurs examinant des plans techniques dans un cadre industriel moderne.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-rfq-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : Acheteur et ing\u00e9nieur examinant une demande de devis de d\u00e9tendeur thermostatique avec sch\u00e9ma de tuyauterie, plaque signal\u00e9tique et \u00e9chantillon de composant.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000042 elementor-widget elementor-widget-text-editor\" data-id=\"h000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une demande de devis solide permet aux fournisseurs de comparer des vannes \u00e9quivalentes et met en \u00e9vidence les donn\u00e9es d'ing\u00e9nierie manquantes d\u00e8s le d\u00e9but. Joignez le PID ou le sch\u00e9ma de tuyauterie et indiquez les points de mesure.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000043 elementor-widget elementor-widget-text-editor\" data-id=\"h000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div aria-label=\"Tableau d\u00e9roulant de d\u00e9tendeur thermostatique 9\" class=\"thermostatic-expansion-valve-guide-table-scroll\" role=\"region\" style=\"max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:28px 0;\" tabindex=\"0\"><table style=\"width:100%;min-width:760px;border-collapse:collapse;\">\n<thead>\n<tr>\n<th>Champ de la demande de devis<\/th>\n<th>Exemple d'entr\u00e9e utile<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Application<\/td>\n<td>Chambre froide \u00e0 temp\u00e9rature moyenne, cong\u00e9lateur basse temp\u00e9rature, refroidisseur de process ou circuit de pompe \u00e0 chaleur<\/td>\n<\/tr>\n<tr>\n<td>Fluide frigorig\u00e8ne<\/td>\n<td>D\u00e9signation exacte, m\u00e9lange ou note de r\u00e9trofit, et type d'huile si pertinent<\/td>\n<\/tr>\n<tr>\n<td>Capacit\u00e9<\/td>\n<td>Capacit\u00e9 de conception avec unit\u00e9s et plage de fonctionnement requise<\/td>\n<\/tr>\n<tr>\n<td>Condition d'\u00e9vaporation<\/td>\n<td>Temp\u00e9rature d'\u00e9vaporation de conception et plage attendue<\/td>\n<\/tr>\n<tr>\n<td>Condition de condensation<\/td>\n<td>Temp\u00e9rature ou pression de condensation de conception et plage ambiante<\/td>\n<\/tr>\n<tr>\n<td>\u00c9tat du liquide<\/td>\n<td>Temp\u00e9rature du liquide, sous-refroidissement et pression \u00e0 l'entr\u00e9e du d\u00e9tendeur thermostatique (TXV)<\/td>\n<\/tr>\n<tr>\n<td>Chute de pression \u00e0 travers la vanne<\/td>\n<td>Chute de pression disponible apr\u00e8s pertes en amont et en aval<\/td>\n<\/tr>\n<tr>\n<td>Circuit d'\u00e9vaporateur<\/td>\n<td>Nombre de circuits, r\u00e9partiteur, chute de pression du circuit et besoin d'\u00e9galiseur externe<\/td>\n<\/tr>\n<tr>\n<td>Construction de la vanne<\/td>\n<td>Mat\u00e9riau du corps, orifice \u00e9quilibr\u00e9 ou conventionnel, orifice rempla\u00e7able et pi\u00e8ces de service<\/td>\n<\/tr>\n<tr>\n<td>Connexions<\/td>\n<td>Taille entr\u00e9e\/sortie, style de connexion, orientation et mat\u00e9riau du tube<\/td>\n<\/tr>\n<tr>\n<td>Documentation<\/td>\n<td>Tableau de capacit\u00e9, d\u00e9claration de compatibilit\u00e9, instructions d'installation, pi\u00e8ces de rechange et dossiers de test<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000044 elementor-widget elementor-widget-text-editor\" data-id=\"h000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Demandez au fournisseur le mod\u00e8le s\u00e9lectionn\u00e9, l'orifice, la charge, l'agencement de l'\u00e9galiseur, la capacit\u00e9 nominale selon vos conditions et toute limite minimale ou maximale de fonctionnement. \u201c TXV, 7\/8 pouce \u201d n'est pas une sp\u00e9cification d'achat compl\u00e8te.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000045 elementor-widget elementor-widget-heading\" data-id=\"h000045\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"quality-and-incoming-inspection-checklist\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Liste de contr\u00f4le qualit\u00e9 et inspection \u00e0 la r\u00e9ception<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000046 elementor-widget elementor-widget-image\" data-id=\"h000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection.webp\" class=\"attachment-full size-full wp-image-7069\" alt=\"Contr\u00f4leur qualit\u00e9 asiatique v\u00e9rifiant les marquages du corps du d\u00e9tendeur thermostatique, l\u2019ampoule de d\u00e9tection, le tube capillaire, les raccordements et l\u2019emballage\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/09\/thermostatic-expansion-valve-guide-inspection-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle : inspecteur qualit\u00e9 asiatique v\u00e9rifiant les marquages du corps du TXV, le bulbe de d\u00e9tection, le tube capillaire, les connexions et l'emballage.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000047 elementor-widget elementor-widget-text-editor\" data-id=\"h000047\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Avant l'installation, inspectez la vanne livr\u00e9e par rapport au dossier d'approbation et \u00e0 la liste de colisage. Le contr\u00f4le doit \u00eatre tra\u00e7able au projet ou au num\u00e9ro de s\u00e9rie de l'\u00e9quipement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000048 elementor-widget elementor-widget-text-editor\" data-id=\"h000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Confirmez le mod\u00e8le, l'orifice, le code de charge, la compatibilit\u00e9 du r\u00e9frig\u00e9rant et les tailles de connexion.<\/li>\n<li>V\u00e9rifiez les marquages du corps, les joints, les capuchons, le bulbe, le tube capillaire, le raccord d'\u00e9galiseur et les accessoires inclus.<\/li>\n<li>V\u00e9rifiez que les capuchons de protection restent en place jusqu'\u00e0 ce que le circuit soit pr\u00eat \u00e0 \u00eatre assembl\u00e9.<\/li>\n<li>Comparez les dimensions re\u00e7ues et le sens d'\u00e9coulement avec le dessin.<\/li>\n<li>Enregistrez tout dommage, corrosion, contamination ou tube capillaire tordu avant l\u2019acceptation.<\/li>\n<li>Conservez la fiche technique du fabricant et les instructions d\u2019installation dans le dossier de l\u2019\u00e9quipement.<\/li>\n<li>Apr\u00e8s l\u2019installation, enregistrez les relev\u00e9s de pression et de temp\u00e9rature comme r\u00e9f\u00e9rence de mise en service.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000049 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"h000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">page de contact Domi<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004a elementor-widget elementor-widget-heading\" data-id=\"h00004a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Questions fr\u00e9quemment pos\u00e9es<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004b elementor-widget elementor-widget-heading\" data-id=\"h00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-is-the-main-function-of-a-thermostatic-expansion-valve\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Quelle est la fonction principale d\u2019un d\u00e9tendeur thermostatique ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004c elementor-widget elementor-widget-text-editor\" data-id=\"h00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un d\u00e9tendeur thermostatique contr\u00f4le le d\u00e9bit du r\u00e9frig\u00e9rant liquide dans un \u00e9vaporateur \u00e0 expansion directe en r\u00e9ponse \u00e0 la surchauffe de sortie. Il aide \u00e0 maintenir l\u2019\u00e9vaporateur actif tout en limitant le risque de retour de liquide par la ligne d\u2019aspiration lorsque la vanne est correctement s\u00e9lectionn\u00e9e, install\u00e9e et mise en service.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004d elementor-widget elementor-widget-heading\" data-id=\"h00004d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-does-a-txv-maintain-superheat\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comment un d\u00e9tendeur thermostatique maintient-il le surchauffe ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004e elementor-widget elementor-widget-text-editor\" data-id=\"h00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La capsule de d\u00e9tection cr\u00e9e une force d\u2019ouverture \u00e0 partir de la temp\u00e9rature de la ligne d\u2019aspiration. La pression de l\u2019\u00e9vaporateur et le ressort cr\u00e9ent des forces de fermeture. Leur \u00e9quilibre d\u00e9place la membrane et modifie l\u2019ouverture de dosage \u00e0 mesure que la charge et la surchauffe de sortie changent.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00004f elementor-widget elementor-widget-heading\" data-id=\"h00004f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"should-i-use-an-internal-or-external-equalizer\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Dois-je utiliser un \u00e9galiseur interne ou externe ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000050 elementor-widget elementor-widget-text-editor\" data-id=\"h000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilisez la conception de la chute de pression de l'\u00e9vaporateur et du r\u00e9partiteur pour d\u00e9cider. Une vanne \u00e0 \u00e9galisation interne peut convenir \u00e0 un circuit compact avec une chute de pression limit\u00e9e. Une vanne \u00e0 \u00e9galisation externe est g\u00e9n\u00e9ralement envisag\u00e9e lorsque la perte de pression \u00e0 travers un r\u00e9partiteur ou un \u00e9vaporateur \u00e0 circuits multiples signifie que la pression du corps de vanne n'est pas repr\u00e9sentative de la sortie de l'\u00e9vaporateur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000051 elementor-widget elementor-widget-heading\" data-id=\"h000051\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-select-a-txv-from-pipe-size-alone\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Puis-je choisir un d\u00e9tendeur thermostatique uniquement en fonction du diam\u00e8tre de la tuyauterie ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000052 elementor-widget elementor-widget-text-editor\" data-id=\"h000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Non. Le diam\u00e8tre de la tuyauterie confirme une contrainte de connexion, pas la capacit\u00e9 de d\u00e9tente ou la r\u00e9ponse de r\u00e9gulation requise. S\u00e9lectionnez en fonction du fluide frigorig\u00e8ne, de la charge, des conditions d\u2019\u00e9vaporation et de condensation, de l\u2019\u00e9tat du liquide, de la perte de charge, de l\u2019arrangement de l\u2019\u00e9galiseur, de la charge du bulbe et des donn\u00e9es de capacit\u00e9 du fabricant.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000053 elementor-widget elementor-widget-heading\" data-id=\"h000053\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-causes-a-txv-to-hunt\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Qu\u2019est-ce qui provoque la chasse d\u2019un d\u00e9tendeur thermostatique ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000054 elementor-widget elementor-widget-text-editor\" data-id=\"h000054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La chasse peut r\u00e9sulter d'une vanne surdimensionn\u00e9e, d'une arriv\u00e9e de liquide instable, d'un mauvais contact ou emplacement du bulbe, d'une charge inadapt\u00e9e, de variations de chute de pression, d'une faible charge ou d'un d\u00e9faut du syst\u00e8me. Relevez la surchauffe au fil du temps et v\u00e9rifiez l'alimentation en liquide ainsi que l'installation avant de modifier le r\u00e9glage ou de remplacer la vanne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000055 elementor-widget elementor-widget-heading\" data-id=\"h000055\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-a-txv-replacement-rfq-include\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Que doit inclure une demande de devis pour le remplacement d\u2019un d\u00e9tendeur thermostatique ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000056 elementor-widget elementor-widget-text-editor\" data-id=\"h000056\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Inclure le mod\u00e8le existant et l\u2019orifice si connu, le fluide frigorig\u00e8ne, la capacit\u00e9, les conditions d\u2019\u00e9vaporation et de condensation, la temp\u00e9rature du liquide ou le sous-refroidissement, la perte de pression disponible, les d\u00e9tails du circuit de l\u2019\u00e9vaporateur et du r\u00e9partiteur, la m\u00e9thode d\u2019\u00e9galisation, les raccordements, la charge du bulbe, la plage d\u2019application et la documentation requise. Ajouter un sch\u00e9ma de tuyauterie lorsque le circuit comporte plusieurs branches ou accessoires.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000057 elementor-widget elementor-widget-heading\" data-id=\"h000057\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"primary-technical-references\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9f\u00e9rences techniques principales<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000058 elementor-widget elementor-widget-text-editor\" data-id=\"h000058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/handbook.ashrae.org\/Handbooks\/R26\/SI\/r26_ch11\/r26_ch11_si.aspx\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Manuel ASHRAE : Dispositifs de contr\u00f4le des r\u00e9frig\u00e9rants<\/a><\/li>\n<li><a href=\"https:\/\/www.danfoss.com\/en-us\/service-and-support\/case-stories\/dcs\/how-thermostatic-expansion-valves-work\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss : Comment fonctionnent les d\u00e9tendeurs thermostatiques<\/a><\/li>\n<li><a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/50825\/AX266348279899en-000101.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Danfoss : Notes pour installateurs : D\u00e9tendeurs thermostatiques<\/a><\/li>\n<li><a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Sporlan\/Sporlan-pdf-files\/Sporlan-pdf-010\/10-11.pdf\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan : Bulletin d\u2019installation du d\u00e9tendeur thermostatique<\/a><\/li>\n<li><a href=\"https:\/\/virtualengineer.parker.com\/myprojects\/Sizing\/Sizing?WFID=3f133247-cf7d-f011-b481-000d3a7abe26\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\" target=\"_blank\" rel=\"noopener\">Parker Sporlan : S\u00e9lection du d\u00e9tendeur thermostatique avec Virtual Engineer<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h000059 elementor-widget elementor-widget-heading\" data-id=\"h000059\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-articles\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Articles associ\u00e9s<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000069 e-con-full e-flex e-con e-parent\" data-id=\"h000069\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h00005e e-con-full e-flex e-con e-parent\" data-id=\"h00005e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h00005b e-con-full e-flex e-con e-parent\" data-id=\"h00005b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005a elementor-widget elementor-widget-text-editor\" data-id=\"h00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/fr\/pieces-du-systeme-de-refrigeration\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Parties d\u2019un syst\u00e8me de r\u00e9frig\u00e9ration : noms des composants, fonctions et applications<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h00005d e-con-full e-flex e-con e-parent\" data-id=\"h00005d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005c elementor-widget elementor-widget-text-editor\" data-id=\"h00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/fr\/cycle-frigorifique\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Cycle frigorifique expliqu\u00e9 : Les 4 \u00e9tapes et les r\u00f4les des serpentins<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000063 e-con-full e-flex e-con e-parent\" data-id=\"h000063\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h000060 e-con-full e-flex e-con e-parent\" data-id=\"h000060\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h00005f elementor-widget elementor-widget-text-editor\" data-id=\"h00005f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/fr\/compresseur-frigorifique\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Compresseur de r\u00e9frig\u00e9ration : Types, dimensionnement et guide de s\u00e9lection OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000062 e-con-full e-flex e-con e-parent\" data-id=\"h000062\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000061 elementor-widget elementor-widget-text-editor\" data-id=\"h000061\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-des-commandes-de-refrigeration\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Guide des commandes de r\u00e9frig\u00e9ration : types, fonctions et param\u00e8tres RFQ<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000068 e-con-full e-flex e-con e-parent\" data-id=\"h000068\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-h000065 e-con-full e-flex e-con e-parent\" data-id=\"h000065\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000064 elementor-widget elementor-widget-text-editor\" data-id=\"h000064\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/fr\/controleur-de-refrigeration\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">R\u00e9gulateur de r\u00e9frig\u00e9ration : Guide de s\u00e9lection pour la temp\u00e9rature, le d\u00e9givrage et les alarmes<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-h000067 e-con-full e-flex e-con e-parent\" data-id=\"h000067\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-h000066 elementor-widget elementor-widget-text-editor\" data-id=\"h000066\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"margin:0;padding:16px;border:1px solid #d8e0e4;border-radius:10px;\"><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-de-selection-des-groupes-frigorifiques\/\" style=\"color:#00566d;text-decoration:underline;text-decoration-thickness:0.08em;text-underline-offset:0.12em\">Guide de s\u00e9lection des unit\u00e9s de r\u00e9frig\u00e9ration pour les syst\u00e8mes commerciaux et OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-h00006a elementor-align-left elementor-widget elementor-widget-button\" data-id=\"h00006a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyez votre sch\u00e9ma de r\u00e9frig\u00e9ration pour examen<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Apprenez comment un d\u00e9tendeur thermostatique contr\u00f4le la surchauffe, comment dimensionner un d\u00e9tendeur thermostatique, et quels r\u00e9frig\u00e9rant, charge, pression et donn\u00e9es de demande de devis les acheteurs doivent confirmer.<\/p>","protected":false},"author":1,"featured_media":7059,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7070","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/comments?post=7070"}],"version-history":[{"count":4,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7070\/revisions"}],"predecessor-version":[{"id":7096,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7070\/revisions\/7096"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/media\/7059"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/media?parent=7070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/categories?post=7070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/tags?post=7070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}