{"id":7147,"date":"2026-10-06T00:38:24","date_gmt":"2026-10-05T16:38:24","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7147"},"modified":"2026-10-06T00:38:24","modified_gmt":"2026-10-05T16:38:24","slug":"guide-de-conception-de-la-tuyauterie-de-refrigerant","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/fr\/refrigerant-piping-design-guide\/","title":{"rendered":"Guide de conception de la tuyauterie frigorifique : dimensionnement des lignes, acheminement et contr\u00f4les des fabricants d'origine"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7147\" class=\"elementor elementor-7147\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000060 e-con-full e-flex e-con e-parent\" data-id=\"nr000060\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000002 e-con-full e-flex e-con e-parent\" data-id=\"nr000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000001 elementor-widget elementor-widget-text-editor\" data-id=\"nr000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La tuyauterie frigorifique relie le compresseur, le condenseur, le d\u00e9tendeur et l'\u00e9vaporateur. Dimensionnez et acheminez chaque segment en fonction du fluide frigorig\u00e8ne s\u00e9lectionn\u00e9, des conditions de fonctionnement, de la plage de capacit\u00e9, de la longueur r\u00e9elle de la ligne, du d\u00e9nivel\u00e9 et des \u00e9quipements raccord\u00e9s. La tuyauterie d'aspiration doit assurer le retour d'huile \u00e0 la charge minimale pr\u00e9vue tout en maintenant la perte de charge dans les limites du compresseur. La tuyauterie de liquide doit acheminer le liquide vers le dispositif de d\u00e9tente sans vaporisation instantan\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000003 elementor-widget elementor-widget-text-editor\" data-id=\"nr000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un raccord d'\u00e9quipement correspond \u00e0 la taille d'un orifice, et non \u00e0 une sp\u00e9cification de ligne sur site. <a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Guide de tuyauterie pour chambres froides de Danfoss<\/a> traite la taille de la ligne comme une fonction du fluide frigorig\u00e8ne, de la capacit\u00e9, de la longueur du parcours, du d\u00e9nivel\u00e9 et des temp\u00e9ratures de fonctionnement. Utilisez les donn\u00e9es du fabricant du compresseur et de l'\u00e9quipement s\u00e9lectionn\u00e9 pour la plage de fonctionnement r\u00e9elle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000004 elementor-widget elementor-widget-image\" data-id=\"nr000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop.webp\" class=\"attachment-full size-full wp-image-7136\" alt=\"Chambre froide avec un condenseur ext\u00e9rieur, un rack de compresseurs, une tuyauterie a\u00e9rienne et une unit\u00e9 d&#039;\u00e9vaporation.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-system-loop-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Aper\u00e7u du syst\u00e8me g\u00e9n\u00e9r\u00e9. Il ne s'agit pas d'une installation Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000005 elementor-widget elementor-widget-heading\" data-id=\"nr000005\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-main-refrigerant-line-types\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quels sont les principaux types de conduites de frigorig\u00e8ne ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000006 elementor-widget elementor-widget-text-editor\" data-id=\"nr000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un syst\u00e8me \u00e0 compression de vapeur comporte g\u00e9n\u00e9ralement trois fonctions de lignes principales. Les syst\u00e8mes complexes peuvent ajouter des d\u00e9rivations, des clarinettes, des conduites de d\u00e9givrage par gaz chaud, des conduites d'\u00e9conomiseur ou des trajets de pompe \u00e0 chaleur r\u00e9versible. Le nom de la ligne d\u00e9crit son \u00e9tat de frigorig\u00e8ne et son sens d'\u00e9coulement, il convient donc de confirmer le circuit r\u00e9el sur le sch\u00e9ma du projet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000007 elementor-widget elementor-widget-text-editor\" data-id=\"nr000007\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Une conduite d'aspiration achemine la vapeur de la sortie de l'\u00e9vaporateur \u00e0 l'entr\u00e9e du compresseur. V\u00e9rifiez le retour d'huile \u00e0 la capacit\u00e9 minimale et maintenez la chute de pression \u00e0 l'aspiration dans les limites du compresseur.<\/li>\n<li>Une conduite de refoulement achemine le gaz chaud du compresseur vers le condenseur. Examinez la classe de pression, la temp\u00e9rature, les vibrations et la migration du frigorig\u00e8ne ou de l'huile.<\/li>\n<li>Une conduite de liquide va du condenseur ou du r\u00e9servoir au d\u00e9tendeur. V\u00e9rifiez la chute de pression afin que le liquide atteigne le dispositif de d\u00e9tente sans vaporisation instantan\u00e9e.<\/li>\n<li>Les d\u00e9rivations et les conduites \u00e0 service sp\u00e9cial g\u00e8rent les clarinettes, le d\u00e9givrage par gaz chaud, les \u00e9conomiseurs ou les circuits r\u00e9versibles. Suivez le sch\u00e9ma de l'\u00e9quipement et les instructions de chaque composant.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000008 elementor-widget elementor-widget-image\" data-id=\"nr000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families.webp\" class=\"attachment-full size-full wp-image-7134\" alt=\"Compresseur de r\u00e9frig\u00e9ration commerciale et \u00e9changeurs de chaleur reli\u00e9s par des chemins de lignes d&#039;aspiration, de refoulement et de liquide.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-line-families-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Illustration conceptuelle. Confirmez le circuit r\u00e9el \u00e0 partir du sch\u00e9ma du projet.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000009 elementor-widget elementor-widget-text-editor\" data-id=\"nr000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une ligne s\u00e9lectionn\u00e9e \u00e0 un point de fonctionnement peut ne pas convenir sur toute la plage. <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEM&amp;PDF=AE-105\" target=\"_blank\" rel=\"noopener\">Manuel de r\u00e9frig\u00e9ration de Copeland<\/a> discute du retour d'huile dans les conduites d'aspiration principales et de d\u00e9rivation \u00e0 charge minimale, ainsi que de la chute de pression dans les conduites de liquide et de gaz chaud. Une r\u00e8gle de diam\u00e8tre unique ne peut pas couvrir ces diff\u00e9rentes conditions. Pour le cycle \u00e0 quatre \u00e9tages et le r\u00f4le de chaque \u00e9changeur de chaleur, voir le <a href=\"https:\/\/domirefrigeration.com\/fr\/cycle-frigorifique\/\">guide du cycle frigorifique<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000a elementor-widget elementor-widget-heading\" data-id=\"nr00000a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"which-inputs-determine-refrigerant-line-size\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quels intrants d\u00e9terminent la taille de la conduite de frigorig\u00e8ne ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000b elementor-widget elementor-widget-text-editor\" data-id=\"nr00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Commencez par la plage de fonctionnement, et non par le diam\u00e8tre ext\u00e9rieur imprim\u00e9 sur un raccord. Enregistrez les donn\u00e9es ci-dessous avant de choisir un abaque de tuyauterie ou un outil de s\u00e9lection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000c elementor-widget elementor-widget-text-editor\" data-id=\"nr00000c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Type de fluide frigorig\u00e8ne et d'huile, y compris toutes les alternatives approuv\u00e9es.<\/li>\n<li>Capacit\u00e9 de refroidissement requise \u00e0 chaque condition de conception, et pas seulement la puissance nominale.<\/li>\n<li>Temp\u00e9ratures ou pressions d'\u00e9vaporation et de condensation, surchauffe et sous-refroidissement lorsque l'outil l'exige.<\/li>\n<li>Mod\u00e8le de compresseur, m\u00e9thode de r\u00e9gulation de la capacit\u00e9, ainsi que points de fonctionnement minimal et maximal.<\/li>\n<li>Fonction de la ligne : aspiration, refoulement, liquide, gaz chaud ou d\u00e9rivation.<\/li>\n<li>Longueur r\u00e9elle du trac\u00e9, longueur \u00e9quivalente des raccordements, d\u00e9nivel\u00e9 vertical (mont\u00e9e ou descente) et emplacement de chaque composant.<\/li>\n<li>Inversion de cycle de la pompe \u00e0 chaleur, d\u00e9givrage, arr\u00eat et conditions de charge partielle modifiant le sens d'\u00e9coulement ou le d\u00e9bit massique.<\/li>\n<li>Mat\u00e9riau des tubes, m\u00e9thode de raccordement, limites de pression et de temp\u00e9rature, isolation, supports et exigences des codes locaux.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000d elementor-widget elementor-widget-image\" data-id=\"nr00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs.webp\" class=\"attachment-full size-full wp-image-7137\" alt=\"Ing\u00e9nieur examinant un trac\u00e9 de tuyauterie de r\u00e9frig\u00e9ration et un calendrier d&#039;\u00e9quipement \u00e0 c\u00f4t\u00e9 d&#039;un syst\u00e8me commercial.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-inputs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Sc\u00e8ne conceptuelle g\u00e9n\u00e9r\u00e9e, et non l'enregistrement d'un projet Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000e elementor-widget elementor-widget-text-editor\" data-id=\"nr00000e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Guide de conception des syst\u00e8mes Danfoss<\/a> \u00e9num\u00e8re le fluide frigorig\u00e8ne, la capacit\u00e9, la longueur de la tuyauterie, l'\u00e9l\u00e9vation et la temp\u00e9rature de fonctionnement parmi les donn\u00e9es d'entr\u00e9e pour la tuyauterie des chambres froides. Il s\u00e9pare \u00e9galement les v\u00e9rifications pour les conduites de liquide, d'aspiration et de refoulement. Utilisez les instructions du fabricant choisi ou un logiciel de dimensionnement approuv\u00e9 pour convertir ces donn\u00e9es en une dimension candidate. Pour le contexte de s\u00e9lection du compresseur, voir le <a href=\"https:\/\/domirefrigeration.com\/fr\/compresseur-frigorifique\/\">guide des compresseurs frigorifiques<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00000f elementor-widget elementor-widget-heading\" data-id=\"nr00000f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-size-refrigerant-lines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment dimensionnez-vous les tuyauteries de fluide frigorig\u00e8ne ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000010 elementor-widget elementor-widget-text-editor\" data-id=\"nr000010\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilisez une s\u00e9quence reproductible pour chaque segment du syst\u00e8me. Ne s\u00e9lectionnez pas la tuyauterie sur la seule base du tonnage nominal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000011 elementor-widget elementor-widget-text-editor\" data-id=\"nr000011\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li><strong>Fixez le cas de conception.<\/strong> Confirmez le fluide frigorig\u00e8ne, les conditions d'\u00e9vaporation et de condensation, la charge thermique, la plage de temp\u00e9rature ambiante et les modes de fonctionnement.<\/li>\n<li><strong>Tracez les segments de tuyauterie.<\/strong> Marquez s\u00e9par\u00e9ment les conduites d'aspiration, de liquide, de refoulement et de service sp\u00e9cial. Notez les d\u00e9rivations, les collecteurs, les changements verticaux et les raccordements des \u00e9quipements.<\/li>\n<li><strong>Mesurez le trac\u00e9.<\/strong> Incluez la longueur droite, les raccords, l'\u00e9l\u00e9vation et les contraintes de routage. Un sch\u00e9ma qui omet le trac\u00e9 risque de ne pas permettre de d\u00e9terminer la taille finale.<\/li>\n<li><strong>S\u00e9lectionnez un candidat dans l'outil ou les tableaux du fabricant de l'\u00e9quipement.<\/strong> Utilisez les donn\u00e9es relatives au fluide frigorig\u00e8ne et \u00e0 la famille de compresseurs sp\u00e9cifi\u00e9s. Ne transf\u00e9rez pas la valeur d'un tableau \u00e0 un autre fluide frigorig\u00e8ne ou \u00e0 une autre plage de fonctionnement sans confirmation.<\/li>\n<li><strong>V\u00e9rifiez la chute de pression et le d\u00e9bit massique.<\/strong> Examinez chaque ligne dans les conditions de conception. La ligne de liquide doit maintenir l'alimentation en liquide vers le dispositif de d\u00e9tendeur ; la perte de pression \u00e0 l'aspiration affecte les conditions d'entr\u00e9e du compresseur.<\/li>\n<li><strong>V\u00e9rifiez le retour d'huile \u00e0 la charge la plus faible pr\u00e9vue.<\/strong> Les compresseurs \u00e0 vitesse variable et les syst\u00e8mes \u00e9tag\u00e9s n\u00e9cessitent une v\u00e9rification \u00e0 charge partielle. Une ligne s\u00e9lectionn\u00e9e uniquement pour la pleine charge peut ne pas transporter l'huile de mani\u00e8re fiable lorsque le d\u00e9bit massique diminue.<\/li>\n<li><strong>Examinez l'installation et les limites de pression.<\/strong> Confirmez le mat\u00e9riau des tuyaux, la classe de pression, la m\u00e9thode de raccordement, les supports, l'isolation, le contr\u00f4le des vibrations et les r\u00e8gles de s\u00e9curit\u00e9 applicables.<\/li>\n<li><strong>Conservez le calcul avec le dessin.<\/strong> Enregistrez l'outil ou la r\u00e9f\u00e9rence du fabricant, les hypoth\u00e8ses, la taille de ligne s\u00e9lectionn\u00e9e et le r\u00e9viseur afin de pouvoir v\u00e9rifier ult\u00e9rieurement les modifications d'\u00e9quipement ou de fluide frigorig\u00e8ne.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000012 elementor-widget elementor-widget-image\" data-id=\"nr000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff.webp\" class=\"attachment-full size-full wp-image-7138\" alt=\"Comparaison conceptuelle de diam\u00e8tres de tuyaux d&#039;aspiration alternatifs illustrant les compromis entre la vitesse et la chute de pression.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-sizing-tradeoff-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Comparaison de concepts uniquement. S\u00e9lectionnez la taille de la ligne pour la plage de fonctionnement r\u00e9elle.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000013 elementor-widget elementor-widget-text-editor\" data-id=\"nr000013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le r\u00e9sultat utile est une conception document\u00e9e pour la plage de fonctionnement sp\u00e9cifi\u00e9e, et non un tableau universel de diam\u00e8tres de tuyaux. Si le fluide frigorig\u00e8ne, la plage de vitesse du compresseur, la condition d'\u00e9vaporation ou le parcours change, effectuez \u00e0 nouveau la s\u00e9lection.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000014 elementor-widget elementor-widget-heading\" data-id=\"nr000014\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"why-is-the-unit-connection-size-not-always-the-field-line-size\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pourquoi la taille de raccordement de l'unit\u00e9 n'est-elle pas toujours la taille de la ligne de terrain ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000015 elementor-widget elementor-widget-text-editor\" data-id=\"nr000015\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un raccordement de compresseur, de condensateur ou d'unit\u00e9 de condensation est une interface de composant. La ligne d'interconnexion a son propre parcours, sa propre longueur, son propre d\u00e9bit et sa propre \u00e9l\u00e9vation. Un orifice et une ligne de terrain peuvent avoir le m\u00eame diam\u00e8tre dans une conception particuli\u00e8re, mais l'orifice seul n'\u00e9tablit pas ce choix.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000016 elementor-widget elementor-widget-text-editor\" data-id=\"nr000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dans un <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/580178\/AB399636244436en-000301.pdf\" target=\"_blank\" rel=\"noopener\">guide d'application sp\u00e9cifique aux unit\u00e9s de condensation Danfoss<\/a>, le fabricant met en garde les utilisateurs contre l'hypoth\u00e8se selon laquelle les raccords d'aspiration et de liquide de l'unit\u00e9 sont de la bonne taille pour la tuyauterie d'interconnexion. Ce guide demande \u00e9galement le dimensionnement sur toute la plage de capacit\u00e9 de l'unit\u00e9. Il s'agit d'un exemple d'application, mais il montre pourquoi une dimension d'orifice ne peut pas \u00e0 elle seule d\u00e9terminer la taille du tuyau de terrain. Confirmez le programme de tuyauterie approuv\u00e9 dans les donn\u00e9es du fabricant de l'\u00e9quipement avant la fabrication ou l'installation. Lors de l'examen d'un dessin, traitez chaque orifice comme une interface, puis v\u00e9rifiez l'ensemble du parcours par rapport aux donn\u00e9es de l'\u00e9quipement s\u00e9lectionn\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000017 elementor-widget elementor-widget-image\" data-id=\"nr000017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs.webp\" class=\"attachment-full size-full wp-image-7139\" alt=\"Manchons de raccordement courts d&#039;unit\u00e9 de condensation \u00e0 c\u00f4t\u00e9 de tuyauteries sur site s\u00e9par\u00e9es achemin\u00e9es \u00e0 travers une zone d&#039;installation.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-connection-stubs-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">L'orifice d'un composant ne d\u00e9termine pas la taille de la ligne de terrain.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000018 elementor-widget elementor-widget-text-editor\" data-id=\"nr000018\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour un ensemble OEM, envoyez simultan\u00e9ment le dessin, le fluide frigorig\u00e8ne, la capacit\u00e9 cible et le programme de tuyauterie. Cela donne au r\u00e9viseur le contexte n\u00e9cessaire pour \u00e9valuer l'orifice d'un ensemble par rapport \u00e0 l'ensemble du parcours d'interconnexion.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000019 elementor-widget elementor-widget-heading\" data-id=\"nr000019\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-part-load-systems-change-suction-line-design\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment les syst\u00e8mes \u00e0 charge partielle modifient-ils la conception de la conduite d'aspiration ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001a elementor-widget elementor-widget-text-editor\" data-id=\"nr00001a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le fonctionnement \u00e0 charge partielle cr\u00e9e un compromis de conception. Une conduite d'aspiration de grand diam\u00e8tre peut r\u00e9duire la perte de charge \u00e0 pleine charge, mais la vitesse du gaz peut chuter trop bas pour assurer le retour d'huile lorsque la capacit\u00e9 ou la vitesse du compresseur est faible. Une conduite plus petite peut maintenir la vitesse \u00e0 faible charge mais cr\u00e9er une chute de pression plus importante \u00e0 un d\u00e9bit plus \u00e9lev\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001b elementor-widget elementor-widget-text-editor\" data-id=\"nr00001b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Certaines applications de compresseurs utilisent une colonne montante divis\u00e9e ou double sur une large plage de capacit\u00e9. Le chemin le plus petit peut assurer le retour d'huile \u00e0 capacit\u00e9 r\u00e9duite ; les deux chemins assurent l'\u00e9coulement \u00e0 charge plus \u00e9lev\u00e9e. Cet agencement d\u00e9pend du compresseur et des conditions de fonctionnement, il ne s'agit donc pas d'un raccourci de modernisation. <a href=\"https:\/\/www.bitzer.de\/shared_media\/html\/est-600\/en-GB\/556451979556454155.html\" target=\"_blank\" rel=\"noopener\">Directives de disposition des tuyaux de BITZER<\/a> d\u00e9crit les colonnes montantes divis\u00e9es pour les syst\u00e8mes \u00e0 capacit\u00e9 command\u00e9e et la n\u00e9cessit\u00e9 de v\u00e9rifier le retour d'huile \u00e0 charge minimale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001c elementor-widget elementor-widget-image\" data-id=\"nr00001c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser.webp\" class=\"attachment-full size-full wp-image-7142\" alt=\"Concept de colonne montante d&#039;aspiration divis\u00e9e avec des branches verticales plus grandes et plus petites entre des collecteurs communs.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-split-riser-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Agencement conceptuel. Confirmez la conception par rapport aux donn\u00e9es d'application du compresseur.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001d elementor-widget elementor-widget-text-editor\" data-id=\"nr00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Demandez au fournisseur du compresseur ou au concepteur du syst\u00e8me de confirmer :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001e elementor-widget elementor-widget-text-editor\" data-id=\"nr00001e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Si le compresseur est \u00e0 vitesse fixe, \u00e9tag\u00e9e ou variable.<\/li>\n<li>Le d\u00e9bit massique stable minimal et la vitesse.<\/li>\n<li>L'\u00e9l\u00e9vation verticale pr\u00e9vue et le calendrier de fonctionnement.<\/li>\n<li>Si une seule colonne montante, une colonne montante divis\u00e9e ou un autre agencement est approuv\u00e9.<\/li>\n<li>Comment le retour d'huile sera v\u00e9rifi\u00e9 lors de la mise en service.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00001f elementor-widget elementor-widget-text-editor\" data-id=\"nr00001f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ne copiez pas une cible de vitesse d'un manuel vers un autre syst\u00e8me. Les valeurs publi\u00e9es s'appliquent au compresseur, au fluide frigorig\u00e8ne, \u00e0 la plage de capacit\u00e9 et aux instructions cit\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000020 elementor-widget elementor-widget-heading\" data-id=\"nr000020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-material-should-refrigerant-piping-use\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quel mat\u00e9riau la tuyauterie de fluide frigorig\u00e8ne doit-elle utiliser ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000021 elementor-widget elementor-widget-text-editor\" data-id=\"nr000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les tubes en cuivre ACR sont courants pour les raccordements sur site dans de nombreuses applications de r\u00e9frig\u00e9ration. <a href=\"https:\/\/store.astm.org\/b0280-23.html\" target=\"_blank\" rel=\"noopener\">ASTM B280-23<\/a> sp\u00e9cifie un tube en cuivre sans soudure pour le service sur site de climatisation et de r\u00e9frig\u00e9ration. La norme ne choisit pas l'\u00e9paisseur de paroi, le diam\u00e8tre, la m\u00e9thode de raccordement ou la classe de pression pour un syst\u00e8me particulier.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000022 elementor-widget elementor-widget-text-editor\" data-id=\"nr000022\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La s\u00e9lection des mat\u00e9riaux doit correspondre au fluide frigorig\u00e8ne, \u00e0 la plage de pression et de temp\u00e9rature, aux homologations des composants, \u00e0 la m\u00e9thode de raccordement, \u00e0 l'environnement et aux exigences locales. Les syst\u00e8mes au CO2 fonctionnent dans des conditions de pression qui n\u00e9cessitent des \u00e9quipements et des tuyauteries con\u00e7us pour cette application. Les syst\u00e8mes A2L ont \u00e9galement des exigences de s\u00e9curit\u00e9 et d'installation sp\u00e9cifiques au fluide frigorig\u00e8ne. Confirmez les tubes et les raccords par rapport \u00e0 la pression de conception et aux instructions pour le syst\u00e8me exact.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000023 elementor-widget elementor-widget-image\" data-id=\"nr000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure.webp\" class=\"attachment-full size-full wp-image-7140\" alt=\"Tubes en cuivre ACR \u00e0 c\u00f4t\u00e9 de vannes et de raccords de r\u00e9frig\u00e9ration dans le cadre d&#039;une comparaison de mat\u00e9riaux conceptuelle.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-material-pressure-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Le mat\u00e9riau et la classe de pression doivent \u00eatre sp\u00e9cifi\u00e9s pour l'application.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000024 elementor-widget elementor-widget-text-editor\" data-id=\"nr000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un dessin d'approvisionnement doit indiquer la norme de tube et le mat\u00e9riau lorsqu'ils sont connus. Si la sp\u00e9cification est incompl\u00e8te, indiquez-la comme un \u00e9l\u00e9ment d'ing\u00e9nierie ouvert plut\u00f4t que de supposer que n'importe quel tube ou raccord en cuivre fonctionnera.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000025 elementor-widget elementor-widget-heading\" data-id=\"nr000025\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-route-length-and-fittings-affect-pressure-drop\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment la longueur du parcours et les raccords affectent-ils la chute de pression ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000026 elementor-widget elementor-widget-text-editor\" data-id=\"nr000026\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le parcours des tuyaux affecte la chute de pression, la charge de fluide frigorig\u00e8ne, le mouvement de l'huile, l'acc\u00e8s pour l'entretien et le co\u00fbt d'installation. Les longs parcours, les nombreux coudes, les d\u00e9rivations sous-dimensionn\u00e9es, les r\u00e9ductions brusques et les \u00e9l\u00e9vations mal plac\u00e9es peuvent modifier le r\u00e9sultat sugg\u00e9r\u00e9 par une recherche sur un tuyau droit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000027 elementor-widget elementor-widget-text-editor\" data-id=\"nr000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Maintenez les longueurs de tuyauterie aussi courtes que le permet la disposition des \u00e9quipements. Utilisez la m\u00e9thode des raccords et des longueurs \u00e9quivalentes requise par l'outil de dimensionnement du fabricant. Ajoutez les variations de niveau et la g\u00e9om\u00e9trie des d\u00e9rivations au mod\u00e8le, puis v\u00e9rifiez le point de fonctionnement le plus d\u00e9favorable. Ne remplacez pas le calcul de perte de charge par une estimation visuelle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000028 elementor-widget elementor-widget-image\" data-id=\"nr000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length.webp\" class=\"attachment-full size-full wp-image-7141\" alt=\"Unit\u00e9s de r\u00e9frig\u00e9ration commerciale reli\u00e9es par des trac\u00e9s de tuyauterie de diff\u00e9rentes longueurs et changements de direction.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-equivalent-length-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Trac\u00e9s illustr\u00e9s. V\u00e9rifiez les longueurs r\u00e9elles des raccords et des d\u00e9nivel\u00e9s dans l'outil s\u00e9lectionn\u00e9.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000029 elementor-widget elementor-widget-text-editor\" data-id=\"nr000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/www.danfoss.com\/en-us\/industries\/food-and-beverage\/dcs\/cold-rooms\/system-design-component-selection\/\" target=\"_blank\" rel=\"noopener\">Le guide de tuyauterie de Danfoss<\/a> conseille de minimiser les changements de direction inutiles et d'\u00e9viter les affaissements susceptibles de cr\u00e9er des pi\u00e8ges \u00e0 huile involontaires. Maintenez les vannes de service, les raccordements des compresseurs, les voyants de liquide et les panneaux amovibles accessibles. Isolez chaque ligne lorsque les instructions de l'\u00e9quipement et les conditions de fonctionnement l'exigent.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002a elementor-widget elementor-widget-heading\" data-id=\"nr00002a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-the-installation-drawing-show\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Que doit montrer le plan d'installation ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002b elementor-widget elementor-widget-text-editor\" data-id=\"nr00002b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un sch\u00e9ma de chantier utile permet \u00e0 un installateur de construire et d'inspecter le trac\u00e9 pr\u00e9vu. L'illustration g\u00e9n\u00e9r\u00e9e ci-dessous montre des exemples d'\u00e9l\u00e9ments de dessin ; elle n'est pas pr\u00eate pour la construction. Listez ces \u00e9l\u00e9ments sp\u00e9cifiques au projet :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002c elementor-widget elementor-widget-image\" data-id=\"nr00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing.webp\" class=\"attachment-full size-full wp-image-7144\" alt=\"Sch\u00e9ma conceptuel de tuyauterie de r\u00e9frig\u00e9ration illustrant une bifurcation, des changements verticaux, des supports et l&#039;acc\u00e8s aux \u00e9quipements.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-installation-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Sch\u00e9ma conceptuel, et non un dessin pr\u00eat pour la construction ou cot\u00e9.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002d elementor-widget elementor-widget-text-editor\" data-id=\"nr00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Sens de circulation et fonction de la ligne pour chaque segment.<\/li>\n<li>Mat\u00e9riau de la tuyauterie, diam\u00e8tre ext\u00e9rieur ou d\u00e9signation nominale, et sp\u00e9cification de paroi le cas \u00e9ch\u00e9ant.<\/li>\n<li>Raccords, d\u00e9rivations, r\u00e9ducteurs, pi\u00e8ges, colonnes montantes et composants d'isolement ou de service.<\/li>\n<li>Emplacements des raccordements des \u00e9quipements et calendrier de raccordement approuv\u00e9.<\/li>\n<li>Limites d'isolation, points de support, travers\u00e9es et d\u00e9tails de contr\u00f4le des vibrations.<\/li>\n<li>Pression et temp\u00e9rature de conception si n\u00e9cessaire pour la s\u00e9lection des mat\u00e9riaux et des composants.<\/li>\n<li>Conditions sp\u00e9ciales pour le d\u00e9givrage par gaz chauds, l'inversion de pompe \u00e0 chaleur, le tirage au vide ou le fonctionnement \u00e0 charge partielle.<\/li>\n<li>La r\u00e9vision du plan et la source des donn\u00e9es de dimensionnement.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002e elementor-widget elementor-widget-image\" data-id=\"nr00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration.webp\" class=\"attachment-full size-full wp-image-7143\" alt=\"Lignes de r\u00e9frig\u00e9ration en cuivre isol\u00e9es et soutenues \u00e0 c\u00f4t\u00e9 d&#039;un compresseur dot\u00e9 d&#039;un raccord flexible.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-support-vibration-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Image conceptuelle g\u00e9n\u00e9r\u00e9e, et non une preuve d'installation Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00002f elementor-widget elementor-widget-text-editor\" data-id=\"nr00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEM&amp;PDF=AE-105\" target=\"_blank\" rel=\"noopener\">Manuel de r\u00e9frig\u00e9ration de Copeland<\/a> traite des supports de tuyauterie, des pi\u00e8ges \u00e0 huile, des vibrations et de la protection des tubes. Respectez l'espacement des supports et la proc\u00e9dure d'assemblage sp\u00e9cifi\u00e9s pour l'\u00e9quipement et le projet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000030 elementor-widget elementor-widget-heading\" data-id=\"nr000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-can-commissioning-checks-confirm-the-piping-design\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment les contr\u00f4les de mise en service peuvent-ils confirmer la conception de la tuyauterie ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000031 elementor-widget elementor-widget-text-editor\" data-id=\"nr000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les rapports de mise en service doivent comparer le comportement r\u00e9el du syst\u00e8me avec la conception approuv\u00e9e. Un technicien ou un ing\u00e9nieur frigoriste qualifi\u00e9 peut v\u00e9rifier les conditions de fonctionnement et les points importants pour l'\u00e9quipement s\u00e9lectionn\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000032 elementor-widget elementor-widget-text-editor\" data-id=\"nr000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Enregistrez le fluide frigorig\u00e8ne, les conditions ambiantes, l'\u00e9tat de charge, l'\u00e9tage ou la vitesse du compresseur, les conditions d'aspiration et de refoulement, l'\u00e9tat de la ligne de liquide et les emplacements de mesure. Comparez la perte de charge et les temp\u00e9ratures de fonctionnement avec les limites du fabricant. Pour les syst\u00e8mes \u00e0 capacit\u00e9 variable, incluez le point de fonctionnement le plus bas que le plan de mise en service peut tester en toute s\u00e9curit\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000033 elementor-widget elementor-widget-image\" data-id=\"nr000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning.webp\" class=\"attachment-full size-full wp-image-7145\" alt=\"Technicien mesurant la pression de r\u00e9frig\u00e9ration et la temp\u00e9rature de la ligne au niveau d&#039;un point de service du compresseur.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-commissioning-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Image conceptuelle g\u00e9n\u00e9r\u00e9e, il ne s'agit pas d'un vrai test ou d'un dossier de service Domi.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000034 elementor-widget elementor-widget-text-editor\" data-id=\"nr000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Des sympt\u00f4mes tels qu'une faible pression d'aspiration, un mauvais niveau d'huile, du gaz flash, des vibrations ou des performances in\u00e9gales des serpentins peuvent avoir plusieurs causes. Ils ne prouvent pas qu'une tuyauterie est sous-dimensionn\u00e9e. V\u00e9rifiez les instruments, la charge, les commandes, les restrictions, le d\u00e9bit d'air et l'\u00e9tat de l'\u00e9quipement avant de modifier la conception de la ligne. La manipulation des frigorig\u00e8nes, le brasage, les tests de pression et la r\u00e9cup\u00e9ration doivent \u00eatre effectu\u00e9s par du personnel qualifi\u00e9 utilisant les proc\u00e9dures de s\u00e9curit\u00e9 applicables.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000035 elementor-widget elementor-widget-heading\" data-id=\"nr000035\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-an-oem-include-in-a-refrigerant-piping-rfq\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Que doit inclure un \u00e9quipementier (OEM) dans une demande de prix (RFQ) pour la tuyauterie de frigorig\u00e8ne ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000036 elementor-widget elementor-widget-text-editor\" data-id=\"nr000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour une \u00e9tude utile de la tuyauterie, envoyez la limite du syst\u00e8me et le cas de fonctionnement. Joignez un sch\u00e9ma unifilaire au dessin ; la taille du raccord d'un compresseur \u00e0 elle seule ne d\u00e9crit pas le trac\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000037 elementor-widget elementor-widget-text-editor\" data-id=\"nr000037\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Application : type d'\u00e9quipement, plage de temp\u00e9rature, emplacement int\u00e9rieur ou ext\u00e9rieur, et cycle de service.<\/li>\n<li>Frigorig\u00e8ne : frigorig\u00e8ne exact, huile et tout autre substitut approuv\u00e9.<\/li>\n<li>Capacit\u00e9 et conditions : service nominal, conditions d'\u00e9vaporation et de condensation, plage ambiante, ainsi que charge minimale et maximale.<\/li>\n<li>\u00c9quipement : compresseur, condenseur, \u00e9vaporateur, d\u00e9tendeur et donn\u00e9es de raccordement.<\/li>\n<li>Trac\u00e9 : longueurs des tron\u00e7ons, variations de hauteur, raccords, d\u00e9rivations et limites d'installation.<\/li>\n<li>Mat\u00e9riaux : norme du tube, mat\u00e9riau, m\u00e9thode de raccordement, pression de conception, isolation et finition.<\/li>\n<li>Modes de fonctionnement : charge partielle, \u00e9tagement, vitesse variable, d\u00e9givrage, r\u00e9cup\u00e9ration par pompe ou inversion de pompe \u00e0 chaleur.<\/li>\n<li>Documents : sch\u00e9ma de tuyauterie, nomenclatures des \u00e9quipements, r\u00e9f\u00e9rence de dimensionnement et r\u00e9vision du dessin.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000038 elementor-widget elementor-widget-image\" data-id=\"nr000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1672\" height=\"941\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing.webp\" class=\"attachment-full size-full wp-image-7146\" alt=\"Sch\u00e9ma de tuyauterie, nomenclature des \u00e9quipements et \u00e9chantillons de raccords dispos\u00e9s pour une revue de conception OEM.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing.webp 1672w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-300x169.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-1024x576.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-768x432.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-1536x864.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-18x10.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/refrigerant-piping-design-guide-rfq-drawing-600x338.webp 600w\" sizes=\"(max-width: 1672px) 100vw, 1672px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Dossier conceptuel. Il ne contient aucune donn\u00e9e r\u00e9elle de client ou de projet.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000039 elementor-widget elementor-widget-text-editor\" data-id=\"nr000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si le syst\u00e8me comprend un \u00e9changeur de chaleur personnalis\u00e9 ou un groupe de condensation, int\u00e9grez l'interface de tuyauterie dans le m\u00eame jeu de dessins que la puissance du serpentin, le frigorig\u00e8ne, les raccordements et l'encombrement d'installation. La page d'ing\u00e9nierie de Domi d\u00e9crit l'assistance pour les exigences de transfert thermique et l'examen des dessins sur les projets d'\u00e9changeurs de chaleur. Confirmez la port\u00e9e d'ing\u00e9nierie demand\u00e9e aupr\u00e8s de l'\u00e9quipe avant de vous y fier pour la conception compl\u00e8te de la tuyauterie du syst\u00e8me.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003a elementor-widget elementor-widget-heading\" data-id=\"nr00003a\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Questions fr\u00e9quemment pos\u00e9es<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003b elementor-widget elementor-widget-heading\" data-id=\"nr00003b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-are-the-different-types-of-refrigerant-pipes\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Quels sont les diff\u00e9rents types de tuyaux de frigorig\u00e8ne ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003c elementor-widget elementor-widget-text-editor\" data-id=\"nr00003c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les trois fonctions principales courantes des lignes sont l'aspiration, le refoulement et le liquide. Un syst\u00e8me plus grand peut \u00e9galement inclure des d\u00e9rivations, des collecteurs, du d\u00e9givrage par gaz chauds, un \u00e9conomiseur ou des lignes de pompe \u00e0 chaleur r\u00e9versible. Le sch\u00e9ma et l'\u00e9tat du frigorig\u00e8ne d\u00e9terminent le nom correct et la v\u00e9rification de la conception.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003d elementor-widget elementor-widget-heading\" data-id=\"nr00003d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-material-is-used-for-refrigerant-piping\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Quel mat\u00e9riau est utilis\u00e9 pour la tuyauterie de frigorig\u00e8ne ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003e elementor-widget elementor-widget-text-editor\" data-id=\"nr00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le tube en cuivre ACR fabriqu\u00e9 selon la norme ASTM B280 est courant dans les travaux de r\u00e9frig\u00e9ration sur site. Le mat\u00e9riau et la sp\u00e9cification de l'\u00e9paisseur de paroi d\u00e9pendent toujours du frigorig\u00e8ne, de la pression de conception, de la temp\u00e9rature, des raccords, de l'approbation de l'\u00e9quipement et de la r\u00e9glementation. N'utilisez pas une d\u00e9signation g\u00e9n\u00e9rale de mat\u00e9riau pour remplacer la sp\u00e9cification du syst\u00e8me.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00003f elementor-widget elementor-widget-heading\" data-id=\"nr00003f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-size-refrigerant-lines\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comment dimensionnez-vous les tuyauteries de fluide frigorig\u00e8ne ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000040 elementor-widget elementor-widget-text-editor\" data-id=\"nr000040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilisez le tableau ou l'outil de dimensionnement du fabricant de l'\u00e9quipement s\u00e9lectionn\u00e9 avec le frigorig\u00e8ne, la capacit\u00e9, les conditions d'\u00e9vaporation et de condensation, la longueur du trac\u00e9, l'\u00e9l\u00e9vation, les raccords et la plage de pleine capacit\u00e9. V\u00e9rifiez le retour d'huile \u00e0 l'aspiration \u00e0 charge minimale et la chute de pression aux points de fonctionnement requis.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000041 elementor-widget elementor-widget-heading\" data-id=\"nr000041\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"are-refrigerant-line-sizes-standard\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Les tailles de lignes de frigorig\u00e8ne sont-elles standard ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000042 elementor-widget elementor-widget-text-editor\" data-id=\"nr000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les tubes sont disponibles dans des tailles standard, mais une liste de tailles standard n'identifie pas la bonne taille pour un syst\u00e8me. Utilisez le fluide frigorig\u00e8ne, les conditions de fonctionnement, le trac\u00e9 de la ligne, la capacit\u00e9, la limite de pression et les instructions du fabricant pour s\u00e9lectionner le tuyau.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000043 elementor-widget elementor-widget-heading\" data-id=\"nr000043\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-use-the-same-size-as-the-compressor-connection\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Puis-je utiliser la m\u00eame taille que le raccord du compresseur ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000044 elementor-widget elementor-widget-text-editor\" data-id=\"nr000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pas automatiquement. Le raccord du compresseur est une dimension d'orifice. Le tuyau d'interconnexion doit \u00eatre s\u00e9lectionn\u00e9 pour l'ensemble du circuit et de la plage de fonctionnement. V\u00e9rifiez les donn\u00e9es d'\u00e9quipement approuv\u00e9es et le calcul de la ligne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000045 elementor-widget elementor-widget-heading\" data-id=\"nr000045\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-a-larger-suction-line-always-improve-performance\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Une ligne d'aspiration plus grande am\u00e9liore-t-elle toujours les performances ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000046 elementor-widget elementor-widget-text-editor\" data-id=\"nr000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Non. Un diam\u00e8tre plus grand peut r\u00e9duire le frottement \u00e0 un d\u00e9bit plus \u00e9lev\u00e9, mais il peut \u00e9galement r\u00e9duire la vitesse du gaz lorsque le syst\u00e8me fonctionne \u00e0 faible capacit\u00e9. La s\u00e9lection doit \u00e9quilibrer la chute de pression et le retour d'huile sur toute la plage de charge r\u00e9elle.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000047 elementor-widget elementor-widget-heading\" data-id=\"nr000047\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-co2-use-the-same-refrigerant-piping-as-an-hfc-system\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Le CO2 utilise-t-il la m\u00eame tuyauterie de fluide frigorig\u00e8ne qu'un syst\u00e8me HFC ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000048 elementor-widget elementor-widget-text-editor\" data-id=\"nr000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ne le pr\u00e9sumez pas. Les syst\u00e8mes au CO2 ont des exigences de pression diff\u00e9rentes et peuvent n\u00e9cessiter des tuyaux, des raccords, des vannes et des composants de s\u00e9curit\u00e9 diff\u00e9rents. Suivez la conception approuv\u00e9e du syst\u00e8me au CO2 et les donn\u00e9es d'\u00e9quipement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000049 elementor-widget elementor-widget-heading\" data-id=\"nr000049\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-i-send-for-a-refrigerant-piping-review\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Que dois-je envoyer pour un examen de la tuyauterie de fluide frigorig\u00e8ne ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004a elementor-widget elementor-widget-text-editor\" data-id=\"nr00004a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Envoyez le sch\u00e9ma de tuyauterie, le fluide frigorig\u00e8ne, la capacit\u00e9 et les conditions de fonctionnement, les mod\u00e8les de composants, les longueurs de lignes et les \u00e9l\u00e9vations, la disposition des raccords, la sp\u00e9cification des mat\u00e9riaux et les modes de fonctionnement. Incluez la r\u00e9vision du dessin et indiquez quelles valeurs sont confirm\u00e9es par rapport \u00e0 celles qui sont encore en cours d'examen.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004b elementor-widget elementor-widget-heading\" data-id=\"nr00004b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"review-the-coil-and-piping-interface-before-release\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Examinez l'interface de l'\u00e9changeur et de la tuyauterie avant la lib\u00e9ration<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004c elementor-widget elementor-widget-text-editor\" data-id=\"nr00004c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si votre projet comprend un \u00e9vaporateur, un condenseur ou un groupe de condensation sur mesure, envoyez le dessin, le fluide frigorig\u00e8ne, la cible de capacit\u00e9, les conditions de fonctionnement et le calendrier des raccords de tuyauterie avec la demande de devis (RFQ). L'\u00e9quipe de Domi d\u00e9crit l'examen des dessins et l'assistance en ing\u00e9nierie thermique pour les projets d'\u00e9changeurs de chaleur. Demandez \u00e0 l'\u00e9quipe de confirmer si l'examen de la tuyauterie demand\u00e9 rel\u00e8ve de la port\u00e9e du projet.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004d elementor-widget elementor-widget-text-editor\" data-id=\"nr00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/capacites-dingenierie\/\">D\u00e9couvrez les capacit\u00e9s d'ing\u00e9nierie de Domi<\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004e elementor-align-left elementor-widget elementor-widget-button\" data-id=\"nr00004e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyer une demande de projet<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00004f elementor-widget elementor-widget-heading\" data-id=\"nr00004f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-articles\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Articles associ\u00e9s<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005f e-con-full e-flex e-con e-parent\" data-id=\"nr00005f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000054 e-con-full e-flex e-con e-parent\" data-id=\"nr000054\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000051 e-con-full e-flex e-con e-parent\" data-id=\"nr000051\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000050 elementor-widget elementor-widget-text-editor\" data-id=\"nr000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-de-selection-des-groupes-frigorifiques\/\">Guide de s\u00e9lection des unit\u00e9s de r\u00e9frig\u00e9ration pour les syst\u00e8mes commerciaux et OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000053 e-con-full e-flex e-con e-parent\" data-id=\"nr000053\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000052 elementor-widget elementor-widget-text-editor\" data-id=\"nr000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/compresseur-frigorifique\/\">Compresseur de r\u00e9frig\u00e9ration : Types, dimensionnement et guide de s\u00e9lection OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000059 e-con-full e-flex e-con e-parent\" data-id=\"nr000059\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr000056 e-con-full e-flex e-con e-parent\" data-id=\"nr000056\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000055 elementor-widget elementor-widget-text-editor\" data-id=\"nr000055\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-des-commandes-de-refrigeration\/\">Guide des commandes de r\u00e9frig\u00e9ration : types, fonctions et param\u00e8tres RFQ<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr000058 e-con-full e-flex e-con e-parent\" data-id=\"nr000058\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr000057 elementor-widget elementor-widget-text-editor\" data-id=\"nr000057\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/cycle-frigorifique\/\">Cycle frigorifique expliqu\u00e9 : Les 4 \u00e9tapes et les r\u00f4les des serpentins<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005e e-con-full e-flex e-con e-parent\" data-id=\"nr00005e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-nr00005b e-con-full e-flex e-con e-parent\" data-id=\"nr00005b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00005a elementor-widget elementor-widget-text-editor\" data-id=\"nr00005a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/heat-pump-system-guide\/\">Guide des syst\u00e8mes de pompe \u00e0 chaleur pour les acheteurs OEM<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-nr00005d e-con-full e-flex e-con e-parent\" data-id=\"nr00005d\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-nr00005c elementor-widget elementor-widget-text-editor\" data-id=\"nr00005c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/domirefrigeration.com\/fr\/product\/bati-de-compresseurs-de-refrigeration-industrielle-pour-entrepot-frigorifique\/\">Rack de compresseurs de r\u00e9frig\u00e9ration industrielle pour stockage frigorifique<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Apprenez les param\u00e8tres de dimensionnement des lignes de fluide frigorig\u00e8ne, les v\u00e9rifications du retour d'huile \u00e0 l'aspiration, les limites de chute de pression, le routage et ce que les acheteurs OEM doivent inclure dans une RFQ de tuyauterie.<\/p>","protected":false},"author":1,"featured_media":7135,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[42],"tags":[],"class_list":["post-7147","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology-popularization"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7147","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/comments?post=7147"}],"version-history":[{"count":3,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7147\/revisions"}],"predecessor-version":[{"id":7150,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7147\/revisions\/7150"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/media\/7135"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/media?parent=7147"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/categories?post=7147"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/tags?post=7147"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}