{"id":7296,"date":"2026-10-17T23:32:42","date_gmt":"2026-10-17T15:32:42","guid":{"rendered":"https:\/\/domirefrigeration.com\/?p=7296"},"modified":"2026-10-17T23:36:58","modified_gmt":"2026-10-17T15:36:58","slug":"surchauffe-et-sous-refroidissement","status":"publish","type":"post","link":"https:\/\/domirefrigeration.com\/fr\/superheat-and-subcooling\/","title":{"rendered":"Superchauffe et sous-refroidissement : calculs, mesures et diagnostic de l'\u00e9vaporateur"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"7296\" class=\"elementor elementor-7296\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000b9 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt0000a8 e-con-full e-flex e-con e-parent\" data-id=\"rt0000a8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000002 e-con-full e-flex e-con e-parent\" data-id=\"rt000002\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000001 elementor-widget elementor-widget-text-editor\" data-id=\"rt000001\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La surchauffe correspond \u00e0 la temp\u00e9rature de vapeur mesur\u00e9e moins sa temp\u00e9rature de saturation \u00e0 la m\u00eame pression. Le sous-refroidissement correspond \u00e0 la temp\u00e9rature de saturation moins la temp\u00e9rature du liquide mesur\u00e9e \u00e0 la m\u00eame pression. Pour les m\u00e9langes de fluides frigorig\u00e8nes pr\u00e9sentant un glissement de temp\u00e9rature, utilisez la valeur de ros\u00e9e pour la surchauffe et la valeur de bulle pour le sous-refroidissement. Comparez les deux mesures aux exigences du fabricant de l\u2019\u00e9quipement avant de diagnostiquer une panne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000003 elementor-widget elementor-widget-text-editor\" data-id=\"rt000003\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les ing\u00e9nieurs des fabricants d\u2019\u00e9quipements d\u2019origine (OEM) et les \u00e9quipes de maintenance frigorifique doivent d\u00e9terminer les v\u00e9rifications \u00e0 effectuer ensuite. Une mesure inattendue peut n\u00e9cessiter un contr\u00f4le de la sonde ou un examen plus approfondi de l\u2019alimentation en fluide frigorig\u00e8ne. L\u2019ajout de fluide frigorig\u00e8ne ou le remplacement de l\u2019\u00e9vaporateur n\u00e9cessite davantage de preuves.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000004 elementor-widget elementor-widget-text-editor\" data-id=\"rt000004\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ce guide couvre les syst\u00e8mes conventionnels de r\u00e9frig\u00e9ration et de refroidissement \u00e0 d\u00e9tente directe en r\u00e9gime subcritique. Il n\u2019applique pas les calculs conventionnels de sous-refroidissement du condenseur \u00e0 un refroidisseur de gaz CO2 transcritique. La manipulation des fluides frigorig\u00e8nes et les raccordements de service doivent \u00eatre effectu\u00e9s par du personnel qualifi\u00e9, conform\u00e9ment aux proc\u00e9dures du fabricant de l\u2019\u00e9quipement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000005 elementor-widget elementor-widget-text-editor\" data-id=\"rt000005\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Aller \u00e0 : <a href=\"#how-do-you-calculate-superheat-and-subcooling\"><u>calculs<\/u><\/a>, <a href=\"#where-should-pressure-and-temperature-be-measured\"><u>points de mesure<\/u><\/a>, <a href=\"#dew-or-bubble-which-p-t-value-should-you-use\"><u>ros\u00e9e et bulle<\/u><\/a>, <a href=\"#what-do-high-and-low-readings-suggest\"><u>combinaisons diagnostiques<\/u><\/a>, <a href=\"#worked-oem-example-check-the-probe-before-changing-the-coil\"><u>exemple pratique OEM<\/u><\/a>, ou <a href=\"#build-a-coil-review-packet-from-the-measurements\"><u>param\u00e8tres d\u2019examen du serpentin<\/u><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000006 elementor-widget elementor-widget-text-editor\" data-id=\"rt000006\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les illustrations originales g\u00e9n\u00e9r\u00e9es par IA expliquent les concepts. Il ne s\u2019agit ni de photographies des usines Domi, ni de r\u00e9sultats de mesures r\u00e9elles, ni de plans d\u2019installation. Les exemples num\u00e9riques sont hypoth\u00e9tiques.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000a9 e-con-full e-flex e-con e-parent\" data-id=\"rt0000a9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000007 elementor-widget elementor-widget-heading\" data-id=\"rt000007\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-do-superheat-and-subcooling-measure\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Que mesurent la surchauffe et le sous-refroidissement ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000008 elementor-widget elementor-widget-text-editor\" data-id=\"rt000008\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ces deux grandeurs correspondent \u00e0 des \u00e9carts de temp\u00e9rature rapport\u00e9s \u00e0 l\u2019\u00e9tat de saturation d\u2019un fluide frigorig\u00e8ne. Elles ne repr\u00e9sentent pas la temp\u00e9rature du tuyau elle-m\u00eame, ni la diff\u00e9rence de temp\u00e9rature de l\u2019air de part et d\u2019autre d\u2019un serpentin.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000009 elementor-widget elementor-widget-text-editor\" data-id=\"rt000009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La surchauffe d\u00e9crit la vapeur dont la temp\u00e9rature est sup\u00e9rieure \u00e0 celle de la limite de vapeur satur\u00e9e. Le sous-refroidissement d\u00e9crit le liquide dont la temp\u00e9rature est inf\u00e9rieure \u00e0 celle de la limite de liquide satur\u00e9. Pour un fluide frigorig\u00e8ne \u00e0 composant unique, il existe une seule temp\u00e9rature de saturation \u00e0 une pression donn\u00e9e. Un m\u00e9lange pr\u00e9sentant un glissement de temp\u00e9rature n\u00e9cessite la r\u00e9f\u00e9rence appropri\u00e9e pour la vapeur ou le liquide.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000a elementor-widget elementor-widget-image\" data-id=\"rt00000a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states.webp\" class=\"attachment-full size-full wp-image-7284\" alt=\"Tuyaux en cuivre montrant les \u00e9tats vapeur et liquide dans un syst\u00e8me frigorifique.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-phase-states-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000020 e-con-full e-flex e-con e-parent\" data-id=\"rt000020\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000011 e-con-full elementor-hidden-mobile e-flex e-con e-parent\" data-id=\"rt000011\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00000c e-con-full e-flex e-con e-parent\" data-id=\"rt00000c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000b elementor-widget elementor-widget-text-editor\" data-id=\"rt00000b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Quantit\u00e9<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00000e e-con-full e-flex e-con e-parent\" data-id=\"rt00000e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000d elementor-widget elementor-widget-text-editor\" data-id=\"rt00000d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9tat du fluide frigorig\u00e8ne \u00e9valu\u00e9<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000010 e-con-full e-flex e-con e-parent\" data-id=\"rt000010\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00000f elementor-widget elementor-widget-text-editor\" data-id=\"rt00000f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Question pratique<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000018 e-con-full e-flex e-con e-parent\" data-id=\"rt000018\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000013 e-con-full e-flex e-con e-parent\" data-id=\"rt000013\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000012 elementor-widget elementor-widget-text-editor\" data-id=\"rt000012\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Quantit\u00e9 :<\/strong> Surchauffe<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000015 e-con-full e-flex e-con e-parent\" data-id=\"rt000015\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000014 elementor-widget elementor-widget-text-editor\" data-id=\"rt000014\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9tat du fluide frigorig\u00e8ne \u00e9valu\u00e9 :<\/strong> Vapeur par rapport \u00e0 la vapeur satur\u00e9e locale<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000017 e-con-full e-flex e-con e-parent\" data-id=\"rt000017\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000016 elementor-widget elementor-widget-text-editor\" data-id=\"rt000016\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Question pratique :<\/strong> La condition mesur\u00e9e \u00e0 la sortie est-elle conforme aux exigences de l\u2019\u00e9vaporateur et du compresseur ?<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001f e-con-full e-flex e-con e-parent\" data-id=\"rt00001f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00001a e-con-full e-flex e-con e-parent\" data-id=\"rt00001a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000019 elementor-widget elementor-widget-text-editor\" data-id=\"rt000019\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Quantit\u00e9 :<\/strong> Sous-refroidissement<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001c e-con-full e-flex e-con e-parent\" data-id=\"rt00001c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001b elementor-widget elementor-widget-text-editor\" data-id=\"rt00001b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9tat du fluide frigorig\u00e8ne \u00e9valu\u00e9 :<\/strong> Liquide par rapport au liquide satur\u00e9 local<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00001e e-con-full e-flex e-con e-parent\" data-id=\"rt00001e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00001d elementor-widget elementor-widget-text-editor\" data-id=\"rt00001d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Question pratique :<\/strong> La marge de liquide est-elle suffisante au point o\u00f9 elle est n\u00e9cessaire ?<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000021 elementor-widget elementor-widget-text-editor\" data-id=\"rt000021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <a href=\"https:\/\/domirefrigeration.com\/fr\/cycle-frigorifique\/\"><u>guide du cycle frigorifique<\/u><\/a> explique le circuit complet. Ici, l'accent est mis sur le relev\u00e9 des mesures et les d\u00e9cisions qu'il permet de prendre.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000aa e-con-full e-flex e-con e-parent\" data-id=\"rt0000aa\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000022 elementor-widget elementor-widget-heading\" data-id=\"rt000022\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-you-calculate-superheat-and-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment calculer la surchauffe et le sous-refroidissement ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000023 elementor-widget elementor-widget-text-editor\" data-id=\"rt000023\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilisez la d\u00e9signation du fluide frigorig\u00e8ne, la pression locale mesur\u00e9e et les donn\u00e9es pression-temp\u00e9rature appropri\u00e9es pour obtenir la r\u00e9f\u00e9rence de saturation. Effectuez ensuite la soustraction dans le bon ordre :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000024 elementor-widget elementor-widget-text-editor\" data-id=\"rt000024\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><strong>Surchauffe = temp\u00e9rature mesur\u00e9e sur la ligne de vapeur \u2212 temp\u00e9rature de saturation au point de ros\u00e9e.<\/strong><\/li>\n<li><strong>Sous-refroidissement = temp\u00e9rature de saturation au point de bulle \u2212 temp\u00e9rature mesur\u00e9e sur la ligne de liquide.<\/strong><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000025 elementor-widget elementor-widget-text-editor\" data-id=\"rt000025\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour un fluide frigorig\u00e8ne pur, utilisez sa valeur unique de saturation. Le document de Copeland <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEB&amp;PDF=95-14\" target=\"_blank\" rel=\"noopener\"><u>bulletin 95-14 sur le changement de fluide frigorig\u00e8ne<\/u><\/a> pr\u00e9sente le calcul en utilisant des r\u00e9f\u00e9rences distinctes pour la vapeur et le liquide dans le cas du R-407C. Ne remplacez la temp\u00e9rature du fluide frigorig\u00e8ne par aucune mesure de temp\u00e9rature de l'air.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000026 elementor-widget elementor-widget-heading\" data-id=\"rt000026\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"superheat-calculation-example\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Exemple de calcul de la surchauffe<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000027 elementor-widget elementor-widget-text-editor\" data-id=\"rt000027\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Supposons que la temp\u00e9rature mesur\u00e9e du tuyau \u00e0 la sortie de l'\u00e9vaporateur soit de 16 \u00b0C. La consultation correcte de la table pression-temp\u00e9rature au m\u00eame endroit donne une temp\u00e9rature de ros\u00e9e de 4 \u00b0C.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000028 elementor-widget elementor-widget-text-editor\" data-id=\"rt000028\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Surchauffe = 16 \u2212 4 = 12 K.<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000029 elementor-widget elementor-widget-image\" data-id=\"rt000029\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example.webp\" class=\"attachment-full size-full wp-image-7288\" alt=\"Tuyauterie industrielle avec relev\u00e9s de temp\u00e9rature du tube, du point de ros\u00e9e et de la surchauffe.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-superheat-example-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002a elementor-widget elementor-widget-text-editor\" data-id=\"rt00002a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le r\u00e9sultat est un \u00e9cart de temp\u00e9rature de 12 K. Il ne s'agit ni d'une temp\u00e9rature de tuyau de 12 \u00b0C, ni d'une valeur cible universelle, ni d'une preuve d'un manque de fluide frigorig\u00e8ne. Cet exemple p\u00e9dagogique n'implique aucune correspondance r\u00e9elle entre pression et temp\u00e9rature.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002b elementor-widget elementor-widget-heading\" data-id=\"rt00002b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"subcooling-calculation-example\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Exemple de calcul du sous-refroidissement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002c elementor-widget elementor-widget-text-editor\" data-id=\"rt00002c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Supposons que la temp\u00e9rature de la ligne de liquide soit de 35 \u00b0C. La temp\u00e9rature au point de bulle obtenue \u00e0 partir de la pression mesur\u00e9e au m\u00eame endroit est de 43 \u00b0C.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002d elementor-widget elementor-widget-text-editor\" data-id=\"rt00002d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Sous-refroidissement = 43 \u2212 35 = 8 K.<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002e elementor-widget elementor-widget-image\" data-id=\"rt00002e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example.webp\" class=\"attachment-full size-full wp-image-7289\" alt=\"Diagramme des temp\u00e9ratures d&#039;un syst\u00e8me frigorifique indiquant une temp\u00e9rature de bulle de 43 \u00b0C, une temp\u00e9rature de tuyauterie de 35 \u00b0C et un sous-refroidissement de 8 K.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-subcooling-example-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00002f elementor-widget elementor-widget-text-editor\" data-id=\"rt00002f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un \u00e9cart de temp\u00e9rature de 1 K \u00e9quivaut \u00e0 un \u00e9cart de 1 \u00b0C ou de 1,8 \u00b0F. Ainsi, 12 K correspondent \u00e0 une surchauffe de 21,6 \u00b0F et 8 K \u00e0 un sous-refroidissement de 14,4 \u00b0F. Pour convertir des \u00e9carts de temp\u00e9rature, multipliez ou divisez par 1,8 ; n'ajoutez pas et ne soustrayez pas 32.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ab e-con-full e-flex e-con e-parent\" data-id=\"rt0000ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000030 elementor-widget elementor-widget-heading\" data-id=\"rt000030\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"where-should-pressure-and-temperature-be-measured\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">O\u00f9 faut-il mesurer la pression et la temp\u00e9rature ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000031 elementor-widget elementor-widget-text-editor\" data-id=\"rt000031\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La pression et la temp\u00e9rature doivent correspondre \u00e0 un m\u00eame emplacement du circuit frigorifique, avec une proximit\u00e9 suffisante pour le calcul envisag\u00e9. Un orifice de service facilement accessible peut constituer un mauvais substitut si un r\u00e9gulateur, une longue canalisation ou une perte de charge importante se trouve entre cet orifice et la sonde de temp\u00e9rature.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000032 elementor-widget elementor-widget-text-editor\" data-id=\"rt000032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour la surchauffe \u00e0 la sortie de l'\u00e9vaporateur, identifiez le point de mesure \u00e0 proximit\u00e9 du bulbe thermostatique ou celui sp\u00e9cifi\u00e9 par le fabricant du r\u00e9gulateur. Pour la surchauffe \u00e0 l'entr\u00e9e du compresseur, utilisez l'emplacement de mesure de la pression d'aspiration sp\u00e9cifi\u00e9 par le fabricant du compresseur. Les recommandations de Copeland concernant les mesures en fonctionnement <a href=\"https:\/\/copeland.custhelp.com\/app\/answers\/detail\/a_id\/955\/~\/operating-superheat%2C-subcooling-and-net-oil-pressure\" target=\"_blank\" rel=\"noopener\"><u>distinguent explicitement les deux emplacements<\/u><\/a> et situent la mesure du liquide \u00e0 proximit\u00e9 de l'entr\u00e9e du d\u00e9tendeur lorsque cette condition est celle qui doit \u00eatre v\u00e9rifi\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000033 elementor-widget elementor-widget-image\" data-id=\"rt000033\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet.webp\" class=\"attachment-full size-full wp-image-7285\" alt=\"Vue rapproch\u00e9e d&#039;une batterie frigorifique et d&#039;un tuyau en cuivre isol\u00e9 dans un environnement industriel.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-evaporator-outlet-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000034 elementor-widget elementor-widget-text-editor\" data-id=\"rt000034\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Indiquez l'emplacement dans le r\u00e9sultat : \u201c surchauffe \u00e0 la sortie de l'\u00e9vaporateur \u201d ou \u201c surchauffe \u00e0 l'entr\u00e9e du compresseur \u201d. Une valeur simplement not\u00e9e \u201c SH \u201d oblige la personne charg\u00e9e de la v\u00e9rification suivante \u00e0 deviner o\u00f9 elle a \u00e9t\u00e9 mesur\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000035 elementor-widget elementor-widget-image\" data-id=\"rt000035\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet.webp\" class=\"attachment-full size-full wp-image-7286\" alt=\"Syst\u00e8me de r\u00e9frig\u00e9ration avec sortie de l&#039;\u00e9vaporateur et entr\u00e9e du compresseur \u00e9tiquet\u00e9es.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-compressor-inlet-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000036 elementor-widget elementor-widget-text-editor\" data-id=\"rt000036\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le gain de chaleur et la perte de pression dans la conduite d'aspiration peuvent modifier la marge de saturation entre ces deux points. Une valeur plus \u00e9lev\u00e9e \u00e0 l'entr\u00e9e du compresseur ne signifie pas, \u00e0 elle seule, que l'\u00e9vaporateur est insuffisamment aliment\u00e9. Si un r\u00e9gulateur de pression s\u00e9pare les deux emplacements, indiquez de quel c\u00f4t\u00e9 du r\u00e9gulateur la pression a \u00e9t\u00e9 mesur\u00e9e. Utilisez le <a href=\"https:\/\/domirefrigeration.com\/fr\/guide-de-conception-de-la-tuyauterie-de-refrigerant\/\"><u>guide de conception de la tuyauterie de r\u00e9frig\u00e9rant<\/u><\/a> pour traiter la question distincte du dimensionnement des conduites.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ac e-con-full e-flex e-con e-parent\" data-id=\"rt0000ac\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000037 elementor-widget elementor-widget-heading\" data-id=\"rt000037\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"dew-or-bubble-which-p-t-value-should-you-use\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Point de ros\u00e9e ou point de bulle : quelle valeur P-T faut-il utiliser ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000038 elementor-widget elementor-widget-text-editor\" data-id=\"rt000038\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utiliser <strong>point de ros\u00e9e \/ vapeur satur\u00e9e pour la surchauffe<\/strong> et <strong>point de bulle \/ liquide satur\u00e9 pour le sous-refroidissement<\/strong>. Une temp\u00e9rature interm\u00e9diaire utilis\u00e9e pour l'\u00e9valuation d'une batterie constitue une r\u00e9f\u00e9rence diff\u00e9rente. Elle ne doit pas remplacer implicitement la valeur du point de ros\u00e9e ou du point de bulle dans un calcul de maintenance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000039 elementor-widget elementor-widget-image\" data-id=\"rt000039\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble.webp\" class=\"attachment-full size-full wp-image-7287\" alt=\"\u00c9tiquettes de fluide frigorig\u00e8ne et outils HVAC pour l&#039;entretien des syst\u00e8mes de r\u00e9frig\u00e9ration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-dew-bubble-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003a elementor-widget elementor-widget-text-editor\" data-id=\"rt00003a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Par exemple, supposons qu'un m\u00e9lange hypoth\u00e9tique pr\u00e9sente une temp\u00e9rature au point de bulle de 2 \u00b0C et une temp\u00e9rature au point de ros\u00e9e de 6 \u00b0C \u00e0 la pression mesur\u00e9e \u00e0 la sortie. Si la temp\u00e9rature de la conduite de vapeur est de 10 \u00b0C, sa surchauffe est de 10 \u2212 6 = 4 K. Utiliser le point de bulle donnerait 8 K, soit une erreur de 4 K. Cet exemple illustre le choix de la r\u00e9f\u00e9rence ; il ne constitue pas une table P-T pour un fluide frigorig\u00e8ne particulier.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003b elementor-widget elementor-widget-text-editor\" data-id=\"rt00003b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Indiquez le fluide frigorig\u00e8ne utilis\u00e9 et pr\u00e9cisez si la pression est relative ou absolue. Une soustraction correcte effectu\u00e9e avec le mauvais r\u00e9glage de fluide frigorig\u00e8ne peut tout de m\u00eame produire un r\u00e9sultat apparemment plausible. Conservez la configuration de l'instrument ou la r\u00e9f\u00e9rence P-T avec le relev\u00e9 d'essai afin qu'un autre ing\u00e9nieur puisse reproduire le r\u00e9sultat.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ad e-con-full e-flex e-con e-parent\" data-id=\"rt0000ad\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003c elementor-widget elementor-widget-heading\" data-id=\"rt00003c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-should-normal-superheat-and-subcooling-be\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Quelles devraient \u00eatre les valeurs normales de surchauffe et de sous-refroidissement ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003d elementor-widget elementor-widget-text-editor\" data-id=\"rt00003d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les valeurs cibles d\u00e9pendent de l'\u00e9quipement et de ses conditions de fonctionnement, notamment du fluide frigorig\u00e8ne, du dispositif de d\u00e9tente, de la charge, du point de mesure et des exigences du compresseur. Consultez les instructions de fonctionnement et de charge du fabricant correspondant au mod\u00e8le exact et aux conditions d'essai.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003e elementor-widget elementor-widget-text-editor\" data-id=\"rt00003e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une valeur cible de r\u00e9gulation de l'\u00e9vaporateur et une limite de protection du compresseur r\u00e9pondent \u00e0 deux questions diff\u00e9rentes. Par exemple, les recommandations de Copeland concernant les compresseurs <a href=\"https:\/\/copeland.custhelp.com\/app\/answers\/detail\/a_id\/2269\/~\/superheat-requirement-of-copeland-rft%2C-rrt%2C-rst-compressors\" target=\"_blank\" rel=\"noopener\"><u>RFT, RRT et RST<\/u><\/a> sp\u00e9cifient une surchauffe minimale de 20 \u00b0F, soit environ 11 K, au point de mesure indiqu\u00e9 sur le compresseur. Cette exigence propre \u00e0 un mod\u00e8le ne constitue pas une valeur cible applicable \u00e0 toutes les sorties d'\u00e9vaporateur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00003f elementor-widget elementor-widget-text-editor\" data-id=\"rt00003f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un d\u00e9tendeur \u00e0 orifice fixe, un d\u00e9tendeur thermostatique (TXV) et un d\u00e9tendeur \u00e9lectronique (EEV) ne r\u00e9agissent pas non plus de mani\u00e8re identique aux variations de charge. Certains \u00e9quipements monoblocs utilisent un tableau de charge du fabricant fond\u00e9 sur la surchauffe ou le sous-refroidissement ; d'autres n\u00e9cessitent une charge pes\u00e9e pr\u00e9cise ou une proc\u00e9dure diff\u00e9rente. Une plage de valeurs g\u00e9n\u00e9rique trouv\u00e9e sur Internet ne peut pas remplacer ces instructions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000040 elementor-widget elementor-widget-text-editor\" data-id=\"rt000040\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si la cible d\u2019origine est manquante, demandez-la avant de d\u00e9clarer l\u2019\u00e9chantillon acceptable. Les achats ne doivent pas transformer une valeur observ\u00e9e sur un prototype en limite de production sans l\u2019approbation du service d\u2019ing\u00e9nierie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000ae e-con-full e-flex e-con e-parent\" data-id=\"rt0000ae\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000041 elementor-widget elementor-widget-heading\" data-id=\"rt000041\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"check-the-measurement-before-diagnosing-a-component\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">V\u00e9rifiez la mesure avant de diagnostiquer un composant<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000042 elementor-widget elementor-widget-text-editor\" data-id=\"rt000042\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une sonde de temp\u00e9rature n\u00e9cessite un contact ad\u00e9quat, un positionnement appropri\u00e9 et l\u2019isolation requise conform\u00e9ment \u00e0 ses instructions. Comparez sa lecture avec celle d\u2019un instrument ind\u00e9pendant lorsqu\u2019un faible \u00e9cart pourrait modifier le diagnostic. V\u00e9rifiez la plage de mesure du capteur de pression et si sa r\u00e9f\u00e9rence configur\u00e9e correspond \u00e0 l\u2019appareil install\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000043 elementor-widget elementor-widget-image\" data-id=\"rt000043\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact.webp\" class=\"attachment-full size-full wp-image-7290\" alt=\"Comparaison entre un bon contact et un contact \u00e0 v\u00e9rifier lors du test des capteurs de r\u00e9frig\u00e9ration.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-probe-contact-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000044 elementor-widget elementor-widget-text-editor\" data-id=\"rt000044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le <a href=\"https:\/\/assets.danfoss.com\/documents\/latest\/419557\/BC457625021427en-000103.pdf\" target=\"_blank\" rel=\"noopener\"><u>Guide du r\u00e9gulateur Danfoss EKE 100<\/u><\/a> comprend des entr\u00e9es de diagnostic concernant l\u2019absence de configuration du capteur de temp\u00e9rature, les d\u00e9fauts de signal du transmetteur de pression et les d\u00e9fauts de c\u00e2blage du capteur de la conduite d\u2019aspiration. V\u00e9rifiez ces entr\u00e9es avant de remplacer une vanne ou de modifier la g\u00e9om\u00e9trie de la bobine. Utilisez ce guide uniquement pour les mod\u00e8les de r\u00e9gulateurs qu\u2019il couvre.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000045 elementor-widget elementor-widget-text-editor\" data-id=\"rt000045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Consid\u00e9rons un budget d\u2019erreur hypoth\u00e9tique. Si une mesure de la temp\u00e9rature d\u2019une conduite peut comporter une erreur de \u00b10,5 K et si la temp\u00e9rature de saturation d\u00e9duite de la pression peut comporter une erreur de \u00b10,7 K, la somme conservative de ces deux limites est de \u00b11,2 K. Il ne s\u2019agit pas d\u2019un calcul formel d\u2019incertitude, mais cela montre pourquoi un \u00e9cart de 0,5 K par rapport \u00e0 une valeur cible ne peut pas \u00eatre \u00e9valu\u00e9 sans v\u00e9rifier les instruments.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000046 elementor-widget elementor-widget-text-editor\" data-id=\"rt000046\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lorsqu\u2019un r\u00e9sultat est n\u00e9gatif ou proche de z\u00e9ro, v\u00e9rifiez rapidement la mesure et l\u2019\u00e9tat r\u00e9el de fonctionnement. Une surchauffe calcul\u00e9e n\u00e9gative ne d\u00e9crit pas une vapeur surchauff\u00e9e stable. Elle peut \u00eatre due \u00e0 une r\u00e9f\u00e9rence inadapt\u00e9e, \u00e0 une mesure erron\u00e9e ou \u00e0 une situation n\u00e9cessitant une investigation pour d\u00e9tecter un \u00e9ventuel retour de liquide.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000af e-con-full e-flex e-con e-parent\" data-id=\"rt0000af\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000047 elementor-widget elementor-widget-heading\" data-id=\"rt000047\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-do-high-and-low-readings-suggest\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Que sugg\u00e8rent des valeurs \u00e9lev\u00e9es et faibles ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000048 elementor-widget elementor-widget-text-editor\" data-id=\"rt000048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u201cLes termes \u201d \u00e9lev\u00e9 \u201c et \u201d faible \u00bb d\u00e9signent des valeurs compar\u00e9es \u00e0 la cible correcte de l\u2019\u00e9quipement dans des conditions comparables. Les combinaisons suivantes constituent des pistes d\u2019investigation pour les \u00e9quipements DX conventionnels, et non des codes de d\u00e9faut universels. Les syst\u00e8mes \u00e9quip\u00e9s d\u2019un r\u00e9servoir de liquide, la r\u00e9gulation de capacit\u00e9, les circuits multiples et le fonctionnement transitoire peuvent modifier ces tendances.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00006c e-con-full e-flex e-con e-parent\" data-id=\"rt00006c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00004f e-con-full elementor-hidden-mobile e-flex e-con e-parent\" data-id=\"rt00004f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00004a e-con-full e-flex e-con e-parent\" data-id=\"rt00004a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000049 elementor-widget elementor-widget-text-editor\" data-id=\"rt000049\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Observation combin\u00e9e<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00004c e-con-full e-flex e-con e-parent\" data-id=\"rt00004c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004b elementor-widget elementor-widget-text-editor\" data-id=\"rt00004b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>V\u00e9rification suivante pertinente<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00004e e-con-full e-flex e-con e-parent\" data-id=\"rt00004e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00004d elementor-widget elementor-widget-text-editor\" data-id=\"rt00004d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9l\u00e9ments de preuve encore n\u00e9cessaires<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000056 e-con-full e-flex e-con e-parent\" data-id=\"rt000056\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000051 e-con-full e-flex e-con e-parent\" data-id=\"rt000051\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000050 elementor-widget elementor-widget-text-editor\" data-id=\"rt000050\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Observation combin\u00e9e :<\/strong> Surchauffe \u00e9lev\u00e9e, sous-refroidissement faible<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000053 e-con-full e-flex e-con e-parent\" data-id=\"rt000053\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000052 elementor-widget elementor-widget-text-editor\" data-id=\"rt000052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>V\u00e9rification suivante pertinente :<\/strong> V\u00e9rifiez si le dispositif de d\u00e9tente re\u00e7oit une quantit\u00e9 suffisante de liquide<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000055 e-con-full e-flex e-con e-parent\" data-id=\"rt000055\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000054 elementor-widget elementor-widget-text-editor\" data-id=\"rt000054\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9l\u00e9ments de preuve encore n\u00e9cessaires :<\/strong> Mesures locales correctes, v\u00e9rification de la charge selon la m\u00e9thode approuv\u00e9e et \u00e9l\u00e9ments permettant de confirmer une fuite ou une alimentation en liquide<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00005d e-con-full e-flex e-con e-parent\" data-id=\"rt00005d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000058 e-con-full e-flex e-con e-parent\" data-id=\"rt000058\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000057 elementor-widget elementor-widget-text-editor\" data-id=\"rt000057\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Observation combin\u00e9e :<\/strong> Surchauffe \u00e9lev\u00e9e, sous-refroidissement \u00e9lev\u00e9<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00005a e-con-full e-flex e-con e-parent\" data-id=\"rt00005a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000059 elementor-widget elementor-widget-text-editor\" data-id=\"rt000059\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>V\u00e9rification suivante pertinente :<\/strong> Examiner une alimentation en fluide frigorig\u00e8ne restreinte ou insuffisante alors que du liquide est disponible en amont<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00005c e-con-full e-flex e-con e-parent\" data-id=\"rt00005c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005b elementor-widget elementor-widget-text-editor\" data-id=\"rt00005b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9l\u00e9ments de preuve encore n\u00e9cessaires :<\/strong> Pertes de charge, \u00e9tat du filtre d\u00e9shydrateur, ad\u00e9quation de la vanne et du distributeur, et emplacements des points de mesure<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000064 e-con-full e-flex e-con e-parent\" data-id=\"rt000064\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt00005f e-con-full e-flex e-con e-parent\" data-id=\"rt00005f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00005e elementor-widget elementor-widget-text-editor\" data-id=\"rt00005e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Observation combin\u00e9e :<\/strong> Faible surchauffe, sous-refroidissement \u00e9lev\u00e9<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000061 e-con-full e-flex e-con e-parent\" data-id=\"rt000061\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000060 elementor-widget elementor-widget-text-editor\" data-id=\"rt000060\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>V\u00e9rification suivante pertinente :<\/strong> V\u00e9rifier la charge thermique, le d\u00e9bit d\u2019air de l\u2019\u00e9vaporateur et le fonctionnement du dispositif de d\u00e9tente avant de conclure \u00e0 une surcharge de fluide frigorig\u00e8ne<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000063 e-con-full e-flex e-con e-parent\" data-id=\"rt000063\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000062 elementor-widget elementor-widget-text-editor\" data-id=\"rt000062\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9l\u00e9ments de preuve encore n\u00e9cessaires :<\/strong> Historique de fonctionnement \u00e0 charge stable, r\u00e9ponse de la vanne, \u00e9tat \u00e0 l\u2019entr\u00e9e du compresseur et proc\u00e9dure de charge de l\u2019\u00e9quipement<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00006b e-con-full e-flex e-con e-parent\" data-id=\"rt00006b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-rt000066 e-con-full e-flex e-con e-parent\" data-id=\"rt000066\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000065 elementor-widget elementor-widget-text-editor\" data-id=\"rt000065\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Observation combin\u00e9e :<\/strong> Faible surchauffe, faible sous-refroidissement<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt000068 e-con-full e-flex e-con e-parent\" data-id=\"rt000068\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000067 elementor-widget elementor-widget-text-editor\" data-id=\"rt000067\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>V\u00e9rification suivante pertinente :<\/strong> V\u00e9rifier l\u2019\u00e9tat du syst\u00e8me et la validit\u00e9 des mesures avant d\u2019attribuer une cause<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt00006a e-con-full e-flex e-con e-parent\" data-id=\"rt00006a\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000069 elementor-widget elementor-widget-text-editor\" data-id=\"rt000069\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9l\u00e9ments de preuve encore n\u00e9cessaires :<\/strong> \u00c9tat de d\u00e9marrage\/d\u00e9givrage, r\u00e9f\u00e9rence du fluide frigorig\u00e8ne, charge, r\u00e9gulation et mesures r\u00e9p\u00e9t\u00e9es<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006d elementor-widget elementor-widget-text-editor\" data-id=\"rt00006d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une surchauffe \u00e9lev\u00e9e associ\u00e9e \u00e0 un faible sous-refroidissement peut \u00eatre compatible avec une sous-charge en fluide frigorig\u00e8ne, mais ces deux param\u00e8tres ne suffisent pas \u00e0 eux seuls \u00e0 l\u2019\u00e9tablir. Une surchauffe \u00e9lev\u00e9e associ\u00e9e \u00e0 un sous-refroidissement \u00e9lev\u00e9 peut \u00eatre compatible avec une restriction d\u2019alimentation, mais uniquement si le sous-refroidissement a \u00e9t\u00e9 mesur\u00e9 \u00e0 un emplacement pertinent en amont et si l\u2019architecture du syst\u00e8me permet cette interpr\u00e9tation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006e elementor-widget elementor-widget-text-editor\" data-id=\"rt00006e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>de Copeland <a href=\"https:\/\/copeland.custhelp.com\/app\/answers\/detail\/a_id\/4108\/~\/bubbles-in-the-sight-glass\" target=\"_blank\" rel=\"noopener\"><u>Recommandations concernant le voyant liquide<\/u><\/a> Explique pourquoi des bulles peuvent appara\u00eetre \u00e0 la suite d\u2019une perte de pression lorsque le liquide est proche de la saturation, notamment en pr\u00e9sence de restrictions. Il met en garde contre le fait d\u2019assimiler syst\u00e9matiquement les bulles \u00e0 une charge insuffisante en fluide frigorig\u00e8ne. La pr\u00e9sence de bulles ne constitue pas une consigne d\u2019ajout de fluide frigorig\u00e8ne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00006f elementor-widget elementor-widget-text-editor\" data-id=\"rt00006f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Consigner le prochain contr\u00f4le dans le rapport. En cas de suspicion de restriction d\u2019alimentation, identifier le composant suspect et les mesures de pression n\u00e9cessaires de chaque c\u00f4t\u00e9. Le technicien pourra ainsi v\u00e9rifier cette hypoth\u00e8se avant de remplacer des pi\u00e8ces.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b0 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000070 elementor-widget elementor-widget-heading\" data-id=\"rt000070\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"why-can-condenser-subcooling-differ-from-valve-inlet-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pourquoi le sous-refroidissement au condenseur peut-il diff\u00e9rer de celui \u00e0 l\u2019entr\u00e9e de la vanne ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000071 elementor-widget elementor-widget-text-editor\" data-id=\"rt000071\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le liquide peut absorber de la chaleur ou subir une perte de pression entre le condenseur et le dispositif de d\u00e9tente. Chacune de ces variations peut r\u00e9duire sa marge locale de sous-refroidissement. Une valeur mesur\u00e9e \u00e0 la sortie du condenseur ne prouve donc pas que la m\u00eame marge subsiste apr\u00e8s une longue conduite, une remont\u00e9e verticale, un d\u00e9shydrateur ou un dispositif de r\u00e9gulation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000072 elementor-widget elementor-widget-image\" data-id=\"rt000072\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed.webp\" class=\"attachment-full size-full wp-image-7291\" alt=\"Composants d&#039;un syst\u00e8me de r\u00e9frig\u00e9ration avec tuyaux en cuivre et vannes pour les applications HVAC.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-liquid-feed-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000073 elementor-widget elementor-widget-text-editor\" data-id=\"rt000073\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>de Copeland <a href=\"https:\/\/webapps.copeland.com\/online-product-information\/Publication\/LaunchPDF?Index=AEB&amp;PDF=1212\" target=\"_blank\" rel=\"noopener\"><u>Bulletin technique sur la conception des r\u00e9servoirs : AE17-1212<\/u><\/a> D\u00e9crit le comportement d\u2019un liquide proche de la saturation dans un r\u00e9servoir partiellement rempli ainsi que le risque de vaporisation partielle apr\u00e8s une perte de pression. \u00c9valuez la marge au point concern\u00e9 \u00e0 l\u2019aide des valeurs locales correspondantes de pression et de temp\u00e9rature, plut\u00f4t que d\u2019extrapoler une valeur mesur\u00e9e \u00e0 la sortie du condenseur \u00e0 l\u2019ensemble du syst\u00e8me.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000074 elementor-widget elementor-widget-text-editor\" data-id=\"rt000074\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Si un r\u00e9servoir ou un sous-refroidisseur ind\u00e9pendant est install\u00e9, indiquez-le sur le sch\u00e9ma des points de mesure. Respectez la proc\u00e9dure de charge et de contr\u00f4le du niveau du r\u00e9servoir propre \u00e0 l\u2019\u00e9quipement, plut\u00f4t que de consid\u00e9rer le sous-refroidissement au condenseur comme un indicateur universel de la quantit\u00e9 de fluide frigorig\u00e8ne pr\u00e9sente dans le syst\u00e8me. Comparez des emplacements \u00e9quivalents lors de l\u2019\u00e9valuation des rapports d\u2019essai de deux fournisseurs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000075 elementor-widget elementor-widget-text-editor\" data-id=\"rt000075\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Cette distinction modifie \u00e9galement la demande de prix (RFQ). Demandez si la puissance frigorifique annonc\u00e9e du condenseur comprend une section de sous-refroidissement sp\u00e9cifi\u00e9e et \u00e0 quel emplacement l\u2019\u00e9tat du liquide livr\u00e9 est d\u00e9fini. Ne supposez pas qu\u2019une modification de la surface du condenseur corrigera un probl\u00e8me de tuyauterie en aval.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b1 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000076 elementor-widget elementor-widget-heading\" data-id=\"rt000076\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"could-airflow-or-frosting-be-causing-the-complaint\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Le d\u00e9bit d\u2019air ou la formation de givre pourraient-ils \u00eatre \u00e0 l\u2019origine du probl\u00e8me signal\u00e9 ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000077 elementor-widget elementor-widget-text-editor\" data-id=\"rt000077\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une batterie frigorifique d\u00e9pend autant de son circuit d\u2019air que de son alimentation en fluide frigorig\u00e8ne. V\u00e9rifiez le fonctionnement du ventilateur, le circuit de retour d\u2019air, le chargement des produits, l\u2019\u00e9tat des ailettes et la pr\u00e9sence de givre avant de conclure que la batterie n\u00e9cessite une capacit\u00e9 sup\u00e9rieure.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000078 elementor-widget elementor-widget-image\" data-id=\"rt000078\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check.webp\" class=\"attachment-full size-full wp-image-7292\" alt=\"Comparaison de serpentins d\u2019\u00e9vaporateur de r\u00e9frig\u00e9ration propres et givr\u00e9s en mati\u00e8re d\u2019efficacit\u00e9.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-air-side-check-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000079 elementor-widget elementor-widget-text-editor\" data-id=\"rt000079\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une face d\u2019\u00e9vaporateur obstru\u00e9e modifie la charge thermique transf\u00e9r\u00e9e au fluide frigorig\u00e8ne. La r\u00e9ponse de la surchauffe qui en r\u00e9sulte d\u00e9pend du dispositif de d\u00e9tente et des syst\u00e8mes de r\u00e9gulation. Un d\u00e9tendeur thermostatique (TXV) peut compenser partiellement le probl\u00e8me ; ainsi, une valeur de surchauffe apparemment acceptable ne prouve ni que le d\u00e9bit d\u2019air est suffisant ni que l\u2019armoire frigorifique dispose d\u2019une capacit\u00e9 utile ad\u00e9quate.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007a elementor-widget elementor-widget-text-editor\" data-id=\"rt00007a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De m\u00eame, examinez le d\u00e9bit d\u2019air du condenseur et les conditions \u00e0 son entr\u00e9e lorsque l\u2019\u00e9vacuation de la chaleur est insuffisante. Distinguez les observations : une face de batterie encrass\u00e9e constitue un indice visible ; son effet mesur\u00e9 sur la capacit\u00e9 n\u00e9cessite des donn\u00e9es de fonctionnement. Le <a href=\"https:\/\/domirefrigeration.com\/fr\/serpentin-de-condenseur\/\"><u>guide des serpentins de condenseur<\/u><\/a> traite s\u00e9par\u00e9ment des questions de maintenance et de construction.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007b elementor-widget elementor-widget-text-editor\" data-id=\"rt00007b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour toute demande de remplacement, fournissez des photographies du circuit d'air install\u00e9 ainsi que du serpentin d\u00e9mont\u00e9. Un nouveau serpentin dont les dimensions correspondent \u00e0 celles de l'ancien peut pr\u00e9senter le m\u00eame espace de d\u00e9rivation ou le m\u00eame retour d'air obstru\u00e9.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b2 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007c elementor-widget elementor-widget-heading\" data-id=\"rt00007c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"record-a-stable-operating-condition\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Enregistrer une condition de fonctionnement stable<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007d elementor-widget elementor-widget-text-editor\" data-id=\"rt00007d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les relev\u00e9s effectu\u00e9s pendant le d\u00e9marrage, la descente en temp\u00e9rature, la reprise apr\u00e8s d\u00e9givrage, le fonctionnement cyclique du ventilateur ou un changement de capacit\u00e9 doivent \u00eatre \u00e9tiquet\u00e9s avec l'\u00e9tat correspondant. Ne les comparez pas \u00e0 une valeur cible en r\u00e9gime permanent, sauf si la proc\u00e9dure du fabricant le pr\u00e9voit.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007e elementor-widget elementor-widget-image\" data-id=\"rt00007e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test.webp\" class=\"attachment-full size-full wp-image-7293\" alt=\"R\u00e9frig\u00e9rateur de laboratoire contenant des bouteilles en verre color\u00e9es dans un laboratoire moderne.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-stable-test-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00007f elementor-widget elementor-widget-text-editor\" data-id=\"rt00007f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour une comparaison avec un \u00e9quipementier d'origine (OEM), choisissez une fen\u00eatre d'essai d\u00e9finie et consignez simultan\u00e9ment les relev\u00e9s associ\u00e9s, ainsi que la temp\u00e9rature ambiante, les conditions dans l'armoire ou la pi\u00e8ce, l'\u00e9tat du ventilateur, l'\u00e9tat du compresseur et le comportement de la vanne, lorsque ces donn\u00e9es sont disponibles. Utilisez la proc\u00e9dure de l'\u00e9quipement pour d\u00e9terminer le temps de stabilisation ; un d\u00e9lai d'attente universel ne convient pas \u00e0 tous les syst\u00e8mes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000080 elementor-widget elementor-widget-text-editor\" data-id=\"rt000080\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une moyenne stable peut masquer d'importantes fluctuations. Conservez la plage de valeurs ou l'enregistrement temporel lors de l'analyse d'un ph\u00e9nom\u00e8ne de pompage ou d'une surchauffe faible intermittente. Si le ph\u00e9nom\u00e8ne ne se produit qu'apr\u00e8s l'ouverture d'une porte ou un d\u00e9givrage, conservez cet \u00e9v\u00e9nement dans le dossier d'essai au lieu de le faire dispara\u00eetre par une moyenne.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b3 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000081 elementor-widget elementor-widget-heading\" data-id=\"rt000081\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"worked-oem-example-check-the-probe-before-changing-the-coil\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Exemple pratique OEM : v\u00e9rifier la sonde avant de remplacer le serpentin<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000082 elementor-widget elementor-widget-text-editor\" data-id=\"rt000082\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Supposons qu'une armoire de d\u00e9veloppement pr\u00e9sente une <strong>valeur cible d'essai approuv\u00e9e hypoth\u00e9tique<\/strong> de 6 \u00b1 1 K de surchauffe \u00e0 la sortie de l'\u00e9vaporateur et de 6 \u00e0 10 K de sous-refroidissement \u00e0 l'entr\u00e9e de la vanne, pour un point de fonctionnement d\u00e9fini. Ces limites sont fictives et propres \u00e0 cet exemple ; elles ne doivent pas \u00eatre utilis\u00e9es comme valeurs cibles sur le terrain.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000083 elementor-widget elementor-widget-text-editor\" data-id=\"rt000083\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le premier relev\u00e9 reprend les valeurs p\u00e9dagogiques pr\u00e9c\u00e9dentes : une temp\u00e9rature de sortie de 16 \u00b0C, une r\u00e9f\u00e9rence de ros\u00e9e de 4 \u00b0C et donc une surchauffe de 12 K. Le sous-refroidissement \u00e0 l'entr\u00e9e de la vanne est de 8 K. L'\u00e9quipe propose un \u00e9vaporateur plus grand, car la surchauffe indiqu\u00e9e est \u00e9lev\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000084 elementor-widget elementor-widget-text-editor\" data-id=\"rt000084\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La s\u00e9quence de v\u00e9rification est la suivante :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000085 elementor-widget elementor-widget-text-editor\" data-id=\"rt000085\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol>\n<li>Confirmer que la pression et la temp\u00e9rature correspondent au m\u00eame emplacement de sortie.<\/li>\n<li>V\u00e9rifier le fluide frigorig\u00e8ne et le r\u00e9glage de la r\u00e9f\u00e9rence de ros\u00e9e.<\/li>\n<li>Comparer la sonde de contact \u00e0 une mesure ind\u00e9pendante dans les m\u00eames conditions de fonctionnement.<\/li>\n<li>V\u00e9rifier \u00e0 nouveau le r\u00e9sultat apr\u00e8s avoir corrig\u00e9 l'installation de mesure.<\/li>\n<\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000086 elementor-widget elementor-widget-text-editor\" data-id=\"rt000086\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Supposons que cette investigation r\u00e9v\u00e8le un mauvais contact de la sonde. Lors du nouvel essai hypoth\u00e9tique, avec une sonde correctement install\u00e9e, la temp\u00e9rature mesur\u00e9e est de 10 \u00b0C, tandis que la r\u00e9f\u00e9rence locale de ros\u00e9e reste \u00e0 4 \u00b0C. La surchauffe calcul\u00e9e est d\u00e9sormais de 6 K, soit une valeur comprise dans la plage approuv\u00e9e de cet exemple, sans aucune modification du serpentin.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000087 elementor-widget elementor-widget-text-editor\" data-id=\"rt000087\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le passage de 12 K \u00e0 6 K a permis de corriger un probl\u00e8me de mesure. Il ne d\u00e9montre pas une am\u00e9lioration de la capacit\u00e9 du serpentin. Si l'armoire ne satisfait toujours pas aux exigences de temp\u00e9rature, examinez la charge r\u00e9siduelle, le d\u00e9bit d'air, les commandes et les performances du syst\u00e8me en vous appuyant sur les relev\u00e9s corrig\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b4 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000088 elementor-widget elementor-widget-heading\" data-id=\"rt000088\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"build-a-coil-review-packet-from-the-measurements\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Constituer un dossier d'examen du serpentin \u00e0 partir des mesures<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000089 elementor-widget elementor-widget-text-editor\" data-id=\"rt000089\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>D\u00e8s lors que les \u00e9l\u00e9ments disponibles confirment un probl\u00e8me li\u00e9 \u00e0 un composant, reliez les relev\u00e9s de fonctionnement au serpentin concern\u00e9. Incluez l'indice de r\u00e9vision du plan afin que le fournisseur puisse \u00e9tablir le lien entre le probl\u00e8me thermique signal\u00e9 et la pi\u00e8ce examin\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008a elementor-widget elementor-widget-image\" data-id=\"rt00008a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release.webp\" class=\"attachment-full size-full wp-image-7294\" alt=\"Composant de r\u00e9frig\u00e9ration industrielle accompagn\u00e9 de plans techniques et d\u2019instruments de mesure.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-coil-release-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008b elementor-widget elementor-widget-text-editor\" data-id=\"rt00008b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Inclure :<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008c elementor-widget elementor-widget-text-editor\" data-id=\"rt00008c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Mod\u00e8le de l\u2019\u00e9quipement, application pr\u00e9vue, r\u00e9frig\u00e9rant et configuration du dispositif de d\u00e9tente.<\/li>\n<li>Sch\u00e9ma des mesures, pressions locales, temp\u00e9ratures des tuyauteries, r\u00e9f\u00e9rence P-T, r\u00e9sultats calcul\u00e9s et valeurs cibles applicables.<\/li>\n<li>\u00c9tat de fonctionnement, conditions ambiantes, charge, r\u00e9gime des ventilateurs, \u00e9tat de givrage\/d\u00e9givrage et \u00e9volution des param\u00e8tres du r\u00e9gulateur, le cas \u00e9ch\u00e9ant.<\/li>\n<li>Plan du serpentin et indice de r\u00e9vision, dimensions hors tout, disposition des tubes et des ailettes, circuits, raccordements et interfaces de montage.<\/li>\n<li>Puissance frigorifique ou capacit\u00e9 de rejet thermique requise, pertes de charge admissibles et essai de r\u00e9ception de l\u2019\u00e9chantillon.<\/li>\n<li>Quantit\u00e9 d\u2019\u00e9chantillons, quantit\u00e9 de production estim\u00e9e, destination et documents d\u2019inspection requis.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008d elementor-widget elementor-widget-text-editor\" data-id=\"rt00008d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pr\u00e9ciser ce qui est mesur\u00e9, ce qui est calcul\u00e9 et ce qui reste une valeur cible. Si une surface frontale plus grande ou un circuit diff\u00e9rent est propos\u00e9, demander au fournisseur d\u2019indiquer les effets sur le d\u00e9bit d\u2019air, la perte de charge, l\u2019encombrement et le point nominal convenu. La nouvelle conception doit toujours faire l\u2019objet de la validation applicable de l\u2019\u00e9quipement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b5 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008e elementor-widget elementor-widget-heading\" data-id=\"rt00008e\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"frequently-asked-questions\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Questions fr\u00e9quemment pos\u00e9es<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00008f elementor-widget elementor-widget-heading\" data-id=\"rt00008f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"what-is-the-difference-between-superheat-and-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Quelle est la diff\u00e9rence entre la surchauffe et le sous-refroidissement ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000090 elementor-widget elementor-widget-text-editor\" data-id=\"rt000090\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La surchauffe mesure de combien la temp\u00e9rature de la vapeur d\u00e9passe sa temp\u00e9rature de saturation de r\u00e9f\u00e9rence locale. Le sous-refroidissement mesure de combien la temp\u00e9rature du liquide est inf\u00e9rieure \u00e0 sa temp\u00e9rature de saturation de r\u00e9f\u00e9rence locale. Ces deux grandeurs concernent diff\u00e9rentes parties du circuit frigorifique et utilisent des ordres de soustraction oppos\u00e9s. Toutes deux n\u00e9cessitent de conna\u00eetre le r\u00e9frig\u00e9rant appropri\u00e9 et la pression locale.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000091 elementor-widget elementor-widget-heading\" data-id=\"rt000091\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"how-do-i-calculate-superheat-from-a-pressure-reading\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Comment calculer la surchauffe \u00e0 partir d\u2019une mesure de pression ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000092 elementor-widget elementor-widget-text-editor\" data-id=\"rt000092\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Convertir la pression en temp\u00e9rature de saturation de la vapeur du r\u00e9frig\u00e9rant, en utilisant les donn\u00e9es de ros\u00e9e pour un m\u00e9lange. Soustraire cette valeur de la temp\u00e9rature mesur\u00e9e de la conduite de vapeur \u00e0 l\u2019emplacement correspondant. La pression seule ne permet pas de d\u00e9terminer la surchauffe, car la temp\u00e9rature r\u00e9elle de la conduite est \u00e9galement n\u00e9cessaire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000093 elementor-widget elementor-widget-heading\" data-id=\"rt000093\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"do-i-use-dew-or-bubble-for-subcooling\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Faut-il utiliser le point de ros\u00e9e ou le point de bulle pour calculer le sous-refroidissement ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000094 elementor-widget elementor-widget-text-editor\" data-id=\"rt000094\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utiliser la r\u00e9f\u00e9rence de saturation du liquide, ou point de bulle, correspondant \u00e0 la pression mesur\u00e9e du liquide. Soustraire la temp\u00e9rature mesur\u00e9e de la conduite de liquide de cette r\u00e9f\u00e9rence. Utiliser le point de ros\u00e9e pour la surchauffe. Une valeur interm\u00e9diaire destin\u00e9e aux \u00e9valuations de performance ne remplace automatiquement aucune de ces deux m\u00e9thodes de calcul.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000095 elementor-widget elementor-widget-heading\" data-id=\"rt000095\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"does-high-superheat-and-low-subcooling-always-mean-low-refrigerant-charge\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Une surchauffe \u00e9lev\u00e9e et un sous-refroidissement faible indiquent-ils toujours une charge insuffisante de r\u00e9frig\u00e9rant ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000096 elementor-widget elementor-widget-text-editor\" data-id=\"rt000096\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Non. Cette observation peut \u00eatre compatible avec une alimentation insuffisante en liquide dans certains syst\u00e8mes, mais elle ne constitue pas un diagnostic univoque. V\u00e9rifier la qualit\u00e9 des mesures, l\u2019\u00e9tat de fonctionnement, l\u2019architecture du syst\u00e8me, les conditions d\u2019alimentation en liquide et la proc\u00e9dure de v\u00e9rification de la charge pr\u00e9conis\u00e9e par le fabricant avant de d\u00e9cider de l\u2019intervention appropri\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000097 elementor-widget elementor-widget-heading\" data-id=\"rt000097\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-high-subcooling-prove-a-liquid-line-restriction\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Un sous-refroidissement \u00e9lev\u00e9 peut-il prouver la pr\u00e9sence d\u2019une restriction dans la conduite de liquide ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000098 elementor-widget elementor-widget-text-editor\" data-id=\"rt000098\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Non. Sa signification d\u00e9pend de l\u2019emplacement de la mesure et de la configuration du syst\u00e8me. V\u00e9rifier les pertes de pression et l\u2019\u00e9tat du liquide autour de la restriction suspect\u00e9e, ainsi que le fonctionnement des vannes et les informations relatives \u00e0 la charge. Une valeur \u00e9lev\u00e9e en amont ne d\u00e9crit pas l\u2019ensemble de la conduite de liquide.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt000099 elementor-widget elementor-widget-heading\" data-id=\"rt000099\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"is-evaporator-superheat-the-same-as-compressor-superheat\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">La surchauffe \u00e0 l\u2019\u00e9vaporateur est-elle identique \u00e0 la surchauffe au compresseur ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009a elementor-widget elementor-widget-text-editor\" data-id=\"rt00009a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ces deux grandeurs sont mesur\u00e9es \u00e0 des emplacements diff\u00e9rents. Le gain de chaleur et la perte de pression dans la conduite d\u2019aspiration peuvent modifier la marge par rapport \u00e0 la temp\u00e9rature de saturation entre la sortie de l\u2019\u00e9vaporateur et l\u2019entr\u00e9e du compresseur. Consigner l\u2019emplacement de chaque mesure et comparer chaque valeur aux exigences applicables \u00e0 la r\u00e9gulation de l\u2019\u00e9vaporateur ou au compresseur.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009b elementor-widget elementor-widget-heading\" data-id=\"rt00009b\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"can-i-use-the-same-targets-for-r-410a-r-32-and-r-454b\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Puis-je utiliser les m\u00eames valeurs cibles pour le R-410A, le R-32 et le R-454B ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009c elementor-widget elementor-widget-text-editor\" data-id=\"rt00009c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Ne partez pas du principe que c'est possible. Utilisez les donn\u00e9es pression-temp\u00e9rature correspondant exactement au fluide frigorig\u00e8ne concern\u00e9 ainsi que les exigences de fonctionnement du fabricant de l'\u00e9quipement. Une conversion P-T correcte ne constitue qu'une partie de la v\u00e9rification ; les valeurs cibles d\u00e9pendent \u00e9galement du mod\u00e8le de l'\u00e9quipement, de l'emplacement des mesures et des conditions de fonctionnement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009d elementor-widget elementor-widget-heading\" data-id=\"rt00009d\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"when-do-the-readings-justify-replacing-a-coil\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Dans quels cas les relev\u00e9s justifient-ils le remplacement d'une batterie ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009e elementor-widget elementor-widget-text-editor\" data-id=\"rt00009e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Lorsque les \u00e9l\u00e9ments de preuve restants confirment un probl\u00e8me au niveau de la batterie et que le remplacement propos\u00e9 permet de le r\u00e9soudre. V\u00e9rifiez d'abord la qualit\u00e9 des mesures, le d\u00e9bit d'air, l'alimentation en fluide frigorig\u00e8ne et les syst\u00e8mes de r\u00e9gulation. Comparez ensuite la construction et les caract\u00e9ristiques nominales de la batterie avec les exigences de fonctionnement, puis d\u00e9finissez un essai permettant de valider le remplacement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b6 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt00009f elementor-widget elementor-widget-heading\" data-id=\"rt00009f\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"make-the-next-decision-from-a-reproducible-record\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Prenez votre prochaine d\u00e9cision \u00e0 partir d'un relev\u00e9 reproductible<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a0 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Conservez ensemble la pression locale, la temp\u00e9rature des tuyauteries, la r\u00e9f\u00e9rence du fluide frigorig\u00e8ne, l'\u00e9tat de fonctionnement et la valeur cible. V\u00e9rifiez \u00e0 nouveau les mesures avant de conclure qu'un d\u00e9tendeur, un condenseur ou un \u00e9vaporateur est d\u00e9fectueux. Ce relev\u00e9 est utile aux \u00e9quipes de maintenance, d'ing\u00e9nierie et d'approvisionnement, car chacune peut ainsi d\u00e9terminer ce que les chiffres permettent d'\u00e9tablir et ce qui n\u00e9cessite encore des essais.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b7 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a1 elementor-widget elementor-widget-heading\" data-id=\"rt0000a1\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"request-a-coil-review-with-the-operating-evidence\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Demandez une \u00e9tude de votre batterie avec les donn\u00e9es de fonctionnement<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a2 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La page des <a href=\"https:\/\/domirefrigeration.com\/fr\/fabrication-de-batteries-sur-mesure\/\"><u>service de fabrication de serpentins personnalis\u00e9s<\/u><\/a> propose une solution pour examiner les plans, les \u00e9chantillons et les exigences de l'application. Pour un projet d'\u00e9vaporateur ou de condenseur, transmettez ensemble la r\u00e9vision du plan de la batterie et le relev\u00e9 des mesures. Pr\u00e9cisez si vous avez besoin d'un remplacement compatible avec l'installation existante, d'une nouvelle \u00e9tude du point de fonctionnement nominal ou d'une proposition g\u00e9om\u00e9trique dans le cadre d'un programme OEM.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a3 elementor-widget elementor-widget-image\" data-id=\"rt0000a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record.webp\" class=\"attachment-full size-full wp-image-7295\" alt=\"Outils d\u2019entretien des syst\u00e8mes frigorifiques et liste de contr\u00f4le pour la maintenance CVC.\" srcset=\"https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record.webp 1536w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-300x200.webp 300w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-1024x683.webp 1024w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-768x512.webp 768w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-18x12.webp 18w, https:\/\/domirefrigeration.com\/wp-content\/uploads\/2026\/10\/superheat-and-subcooling-rfq-record-600x400.webp 600w\" sizes=\"(max-width: 1536px) 100vw, 1536px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a4 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Indiquez la puissance frigorifique requise, le d\u00e9bit d'air disponible, les limites de perte de charge, les conditions du fluide frigorig\u00e8ne et l'encombrement disponible pour l'installation. Domi peut examiner les informations disponibles et identifier les donn\u00e9es n\u00e9cessaires \u00e0 l'\u00e9tude du projet. La conception finale, les performances, le p\u00e9rim\u00e8tre des inspections, les d\u00e9lais de livraison des \u00e9chantillons et les conditions commerciales doivent \u00eatre confirm\u00e9s conform\u00e9ment aux sp\u00e9cifications convenues.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a5 elementor-align-left elementor-widget elementor-widget-button\" data-id=\"rt0000a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-md\" href=\"https:\/\/domirefrigeration.com\/fr\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Envoyez votre plan de batterie et votre rapport d'essai<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-rt0000b8 e-con-full e-flex e-con e-parent\" data-id=\"rt0000b8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a6 elementor-widget elementor-widget-heading\" data-id=\"rt0000a6\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"related-refrigeration-resources\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Related refrigeration resources<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-rt0000a7 elementor-widget elementor-widget-text-editor\" data-id=\"rt0000a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/domirefrigeration.com\/fr\/cycle-frigorifique\/\"><u>Cycle frigorifique : les quatre \u00e9tapes et le r\u00f4le des batteries<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-de-la-vanne-dexpansion-thermostatique\/\"><u>D\u00e9tendeur thermostatique : surchauffe et s\u00e9lection<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-de-detendeur-electronique\/\"><u>D\u00e9tendeur \u00e9lectronique : r\u00e9gulation et s\u00e9lection<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/fr\/dimensionnement-de-serpentin-de-refrigeration-commerciale\/\"><u>Dimensionnement des batteries de r\u00e9frig\u00e9ration commerciale<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/fr\/guide-de-conception-de-la-tuyauterie-de-refrigerant\/\"><u>Conception des tuyauteries frigorifiques et v\u00e9rifications OEM<\/u><\/a><\/li>\n<li><a href=\"https:\/\/domirefrigeration.com\/fr\/fabrication-de-batteries-sur-mesure\/\"><u>Fabrication de batteries frigorifiques sur mesure<\/u><\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>A practical guide to paired pressure and temperature measurements, worked calculations, diagnostic limits, and the evidence OEM buyers need before changing a refrigeration coil.<\/p>","protected":false},"author":1,"featured_media":7283,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[54],"tags":[],"class_list":["post-7296","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oem-buyer-guides"],"_links":{"self":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/comments?post=7296"}],"version-history":[{"count":6,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7296\/revisions"}],"predecessor-version":[{"id":7302,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/posts\/7296\/revisions\/7302"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/media\/7283"}],"wp:attachment":[{"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/media?parent=7296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/categories?post=7296"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/domirefrigeration.com\/fr\/wp-json\/wp\/v2\/tags?post=7296"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}