Industrial Refrigeration Condenser
99.9% TP2 Copper
After special soft annealing treatment,it is more flexible and easy to process.
The Fins
Use high-quality aluminum alloy,Thin and uniform structure, excellent thermal conductivity, effectively expanding heat exchange area to enhance cooling efficiency.
The Welding Technology
Firm and seamless joint between copper tubes,ensuring minimal heat loss at connection points.High welding strength, resisting vibration during refrigerator and freezer operation, extending service life.
The Protective Cover
The surface of the condenser has been cleaned when leaving the factory.
Dust-proof and moisture-proof, keeping the copper tubes and fins in optimal working condition before installation.
Product Details
Domi Refrigeration supplies Industrial Refrigeration Condenser for OEM buyers who need a drawing-driven component, stable repeat production, and a supplier that can discuss size, material, testing, and packaging before release.
For coil projects, the safest starting point is the old sample, a cabinet sketch, or an approved drawing. That lets the supplier confirm face area, tube pitch, row count, connection position, and mounting pattern before quotation.
Where this product fits
This product is used wherever the system needs efficient heat rejection or heat absorption inside a compact footprint.
- cold storage
- process cooling
- industrial refrigeration platforms
Materials and build options
This product normally needs stronger structural support, more robust headers, and corrosion-aware material selection. The exact tube, fin, and frame combination should follow the approved industrial drawing.
Industrial condensers are often driven by capacity, air path, row count, and installation clearance. Size, lifting points, and service access should be confirmed before release.
Specification guidance
| Item | Guidance |
|---|---|
| Main materials | Heavy-duty tube and fin construction with structural frames and corrosion-aware finish options. |
| Dimensions | Matched to capacity and installation clearance. Confirm lifting, access, and footprint before ordering. |
| Refrigerant / medium | CO2, ammonia, glycol loop, and other industrial-duty media may be discussed when the project drawing specifies them. |
| Pressure / electrical note | Working pressure, test pressure, and safety margin must be confirmed from the industrial system design. Do not release without approved operating conditions. |
| Testing | Testing normally includes dimensional review, surface inspection, joint inspection, and leak testing. For export units, the packing plan should protect fins, corners, and headers during transit. |
| MOQ | MOQ depends on unit size, engineering time, and packaging needs. Small trial orders can be discussed before production commitment. |
| Lead time | Lead time is linked to engineering approval, material sourcing, and packaging complexity. |
| MODEL | CAPACITY | AREA | FAN | CONNECTDIA(MM) | OVERALL(MM) | INSTALLSIZE | |||||
| KW | m² | INPUT(W) | DIA(MM) | VOLTAGE(V) | AIR(m³/H) | INLET | OUTLET | A*B*C | D(MM) | E(MM) | |
| CD-2 | 0.6 | 2 | 1*35 | 200 | 410 | 220 | ø10 | ø10 | 320*100*230 | 270 | 65 |
| CD-3.4 | 1 | 3.4 | 1*35 | 200 | 410 | 220 | ∅12 | ∅12 | 320*100*230 | 270 | 65 |
| CD-4.4 | 1.3 | 4.4 | 1*60 | 250 | 750 | 220 | ∅12 | ∅12 | 370*100*280 | 325 | 65 |
| CD-5.4 | 1.6 | 5.4 | 1*75 | 300 | 1350 | 220 | ∅12 | ∅12 | 440*100*330 | 392 | 65 |
| CD-7 | 2 | 7 | 1*90 | 300 | 1350 | 220 | ∅12 | ∅12 | 440*135*330 | 390 | 90 |
| CD-8.4 | 2.3 | 8.4 | 1*150 | 350 | 3100 | 380 | ∅16 | ∅12 | 500*130*430 | 455 | 95 |
| CD-11.5 | 3.5 | 11.5 | 1*150 | 350 | 3100 | 380 | ∅16 | ∅12 | 480*180*430 | 430 | 145 |
| CD-15 | 4.4 | 15 | 1*150 | 350 | 3100 | 380 | ∅16 | ∅12 | 550*180*480 | 490 | 145 |
| CD-18 | 5.2 | 18 | 1*180 | 400 | 4500 | 380 | ∅19 | ∅12 | 590*180*530 | 530 | 140 |
| CD-22 | 6.4 | 22 | 1*180 | 400 | 4500 | 380 | ∅19 | ∅12 | 590*180*530 | 530 | 140 |
| CD-25 | 8.1 | 25 | 1*180 | 400 | 4500 | 380 | ∅19 | ∅16 | 750*180*680 | 660 | 150 |
| CD-21 | 6.1 | 21 | 2*90 | 300 | 2700 | 220 | ∅16 | ∅12 | 840*180*430 | 790 | 140 |
| CD-28 | 8.2 | 28 | 2*150 | 350 | 6200 | 380 | ∅19 | ∅16 | 900*180*430 | 840 | 145 |
| CD-33 | 11.2 | 33 | 2*150 | 350 | 6200 | 380 | ∅19 | ∅16 | 900*200*480 | 840 | 130 |
| CD-36 | 12.6 | 36 | 2*180 | 400 | 9000 | 380 | ∅16 | ∅12 | 1015*180*580 | 950 | 150 |
| CD-43 | 14.8 | 43 | 2*180 | 400 | 9000 | 380 | ∅16 | ∅12 | 1015*180*680 | 950 | 150 |
| CD-48 | 17.5 | 48 | 2*180 | 400 | 9000 | 380 | ∅16 | ∅12 | 1250*200*630 | 1172 | 120 |
| CD-55 | 19.2 | 55 | 2*180 | 400 | 9000 | 380 | ∅22 | ∅12 | 1250*200*730 | 1172 | 140 |
| CD-70 | 20.5 | 70 | 4*150 | 350 | 12400 | 380 | ∅22 | ∅16 | 1250*200*830 | 1172 | 120 |
| CD-80 | 24.4 | 80 | 4*150 | 350 | 12400 | 380 | ∅28 | ∅16 | 1250*200*930 | 1172 | 120 |
| CD-100 | 29.6 | 100 | 4*180 | 400 | 18000 | 380 | ∅28 | ∅16 | 1250*200*1130 | 1172 | 120 |
| CD-130 | 38.2 | 130 | 4*180 | 400 | 18000 | 380 | ∅28 | ∅22 | 1250*200*1330 | 1172 | 120 |
| CD-150 | 47.2 | 150 | 4*180 | 400 | 18000 | 380 | ∅28 | ∅22 | 1250*200*1330 | 1240 | 200 |
| CD-180 | 54 | 180 | 4*180 | 400 | 18000 | 380 | ∅28 | ∅22 | 1250*270*1330 | 1240 | 200 |
Testing and release checks
Testing normally includes dimensional review, surface inspection, joint inspection, and leak testing. For export units, the packing plan should protect fins, corners, and headers during transit.
Project records should keep the approved drawing, test point, and shipping format so repeated industrial orders stay consistent.
FAQ
Can you confirm the size from a sample or photo?
Yes. A field photo or old installation drawing helps confirm whether the replacement matches the original footprint.
How do you confirm refrigerant, pressure, or operating conditions?
Compatibility must follow the approved industrial design package, especially where pressure and media change the construction requirements.
What is needed for MOQ and lead time confirmation?
Quantity, packaging, and engineering review scope are the main inputs for MOQ and lead time.
Quotation next step
Please send the operating media, pressure class, quantity target, and approved drawing for an industrial quotation review.
Related resources: manufacturing process, quality certifications, and industrial refrigeration coils. For procurement follow-up, request a custom quote.
Get Product Information for Your Project
Send the product model, drawings, sample photos, quantity, or application requirements. Our team will review the information and help confirm suitable options, technical data, and quotation details.